• 제목/요약/키워드: concrete lining

검색결과 319건 처리시간 0.027초

건축벽체용 광택문양콘크리트의 성능평가 연구 (A Study on Building Wall with Glossing Design-Concrete)

  • 김종원;김재은;윤상혁;양동일;조상영;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.573-578
    • /
    • 2003
  • Contemporary architecture calls for a wide range of surface textures and treatments. A surface compatible with the architect's design may vary from a glass-smooth finish to one requiring special sculptured ornamentation. These surfaces require many different types of form sheathing and lining. The purpose of study development new design form and made elaborateness shape. Easy to used in field that architecture finish material not used expect effective reduce of working hours, personnel expenses, architecture finish material, cost. After this, building wall apply a variety shape in concrete surface

  • PDF

터널 화재시나리오에 따른 콘크리트 PC패널 라이닝의 전열특성에 관한 해석적 연구 (An Study on Heat Transfer Analysis to Concrete PC Pannel Lining under Tunnel Fire Scenario)

  • 김형준;김흥열;박경훈;신현준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.487-492
    • /
    • 2009
  • This study was performed FE numerical analysis under 120-minute fire conditions, using the ABAQUS, a wide use software, on the basis of the test results by concrete tunnel lining fire strengths (ISO, RWS, and MHC). The concrete material test was to secure the material properties of concrete linings, which were numerical analysis input conditions. And then built the material properties, such as specific heat, heat transfer rate, heat expansion rate, density, elasticity coefficient and compression strength under high temperature conditions, as database at 20 $^{\circ}C$ to 800 $^{\circ}C$, applying them to analysis as input values. As a result, the tunnel linings under RWS fire conditions saw fire temperature rose to maximum 1119 $^{\circ}C$at the location of 5 mm above a thermal surface, and saw surface temperature amount to 1214 $^{\circ}C$ in the middle part.

  • PDF

배수형 터널과 방수형 터널의 설계와 시공 (Design and Construction of Bottom Drainage Tunnel and the Watertight Tunnel)

  • 김승렬;박광준;박봉기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 봄 학술회 논문집
    • /
    • pp.49-58
    • /
    • 1993
  • Reappraisal of the design and the construction concept of the bottom drainage tunnel has been made through the seepage analysis. An appropriate design approach for this tunnel has also been proposed. It was revealed from this study that water pressures acting on the concrete lining in the bottom dralnage tunnel much depend on the permeability of the surrounding ground, the source of water supply and the discharge capacity of dralnage facilities. The full release of these water pressures by the current drainage system could not be expected if this type of tunnel is constructed in the ground including alluvial deposits having a high permeability. The necessity of a proper reinforcement of the concrete lining or a modification of its shapes corresponding to the water pressure has been suggested.

  • PDF

Composite 라이닝 공법의 배수공 재료인 경량기포모르타르의 공극구조와 배수성능에 대한 고찰 (A Study on the Drain Performance & Pore Structure of Cellular Mortar which Drain Material of the Composite Lining Method)

  • 최희섭;마상준;이흥수;서신석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.425-426
    • /
    • 2009
  • 본 연구는 새로운 터널 공법인 Composite 라이닝 공법의 터널 배수재로 적용될 최적경량기포모르타르 배합을 선정하고자, 기포율 변화에 따른 경량기포모르타르의 공극구조를 분석하였다. 그 결과, 3.0MPa이상의 소요강도 확보와 더불어 투수성에 우수한 연속기포의 형성 및 분포가 가장 잘 이루어진 것으로 예상되는 FCR배합이 적합할 것으로 판단된다.

  • PDF

경량기포 모르타르를 이용한 NATM Composite 라이닝 터널 뒤채움재의 역학적 특성 평가 (An Evaluation of the Mechanical Property for the Backfilling Material of the NATM Composite Lining Tunnel using the Lightweight Foamed Mortar)

  • 마상준;최희섭;김동민;이흥수;김경덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.717-720
    • /
    • 2008
  • This paper, an evaluation of the mechanical property for the backfilling materials of the NATM Composite lining tunnel using the lightweight foamed mortar, relates to the performance of permeability, compressive strength and unit volume weight. Therefore, this study is aimed to prove the three main factor that refered to the above line for development of new tunnel method. As the result of this study, it would be confirmed that the D mix is better than other mixs a side of all tests and its relation that is for the tunnel backfilling materials.

  • PDF

프리스트레인 가변형 광섬유센서를 이용한 지하철 구조 모니터링시스템 (1Monitoring system for the subway structures using pre-strain controllable FBG sensors)

  • 김기수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.700-709
    • /
    • 2009
  • FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well.

  • PDF

교통량과 콘크리트 라이닝 균열 상관관계 분석 (Correlation analysis of traffic and crack in concrete lining)

  • 이규필
    • 한국터널지하공간학회 논문집
    • /
    • 제25권5호
    • /
    • pp.345-355
    • /
    • 2023
  • 본 연구에서는 교통량과 균열 두 변수에 대한 관계성을 분석하기 위하여 공분산 분석 및 피어슨 상관관계 분석을 수행하였다. 이를 위하여 국도터널 216개소에 대한 정밀안전점검, 정밀안전진단 시행결과 및 교통량을 조사/분석하였다. 분석결과 교통량과 콘크리트 라이닝에 발생하는 균열은 높은 상관성을 보이는 것으로 나타났다. 따라서 균열 보수 등 선제적 유지관리는 교통량을 고려한 계획수립을 수행하는 것이 바람직하다.

NATM 터널라이닝 종방향 균열 제어공법 (The control method for axial cracks on NATM tunnel linings)

  • 정수매;박인준
    • 한국터널지하공간학회 논문집
    • /
    • 제11권4호
    • /
    • pp.437-447
    • /
    • 2009
  • 국내외의 수많은 NATM 터널시공 보고서 및 연구로 부터 라이닝 콘크리트에서 재래공법 보다 많은 균열이 발생한다는 것을 쉽게 찾을 수 있다. 그러므로 본 연구에서는 터널 라이닝의 종방향 균열제어 및 방지를 위하여 새로운 공법을 제안 하였으며 제안공법의 효율성을 판단하기 위하여 개별요소법을 이용하여 분석하였다.

대단면 터널 라이닝 거푸집의 조기 제거를 위한 초기 강도 발현 기법 연구 (Research of Early-age Strength Development Technology for Remove the Steel Form of Large-wide Tunnel Lining Concrete)

  • 김광돈;이득복
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.116-127
    • /
    • 2014
  • 대단면 터널 라이닝 콘크리트를 1일에 1cycle로 진행하기 위한 연구를 수행하였다. 터널 내부의 기후특성이 변화하고 콘크리트 타설온도가 낮은 경우에는 수화발현 속도도 지연되어 강도발현에 영향을 미치게 되므로 거푸집의 존치시간이 길어지게 된다. 이를 보완하기 위하여 갱문의 설치와 갱폼의 양쪽에 양생막을 설치한 후, 그 내부에 $28{\pm}2^{\circ}C$의 추가적인 열원을 공급하게 되면 균열관리방안으로 제시한 관리 기준 (4.5MPa) 이상의 조기강도발현을 이루어 낼 수 있었으며, 따라서 거푸집을 재령 14hr 후에 제거할 수가 있었다. 한편, 터널내 자연양생온도인 $10{\pm}1^{\circ}C$ 조건에서는 콘크리트 타설 후 36hr 이상의 양생시간을 확보해야 되는 것으로 분석되었다. 본 연구를 통하여, 초기재령에서의 콘크리트 온도와 강도발현은 양생온도가 크게 작용하고 있음을 재확인 할 수 있었으며, 플라이애쉬가 10% 혼입된 콘크리트라도 일정 시간동안 거푸집의 표면온도를 상승시켜 줄 수 있다면 조기강도발현에는 문제가 되지 않는 것으로 나타났다.

증기양생 조건에 따른 터널 PC 패널의 물리적 특성에 관한 연구 (The study on mechanical properties of PC panel with steam curing condition)

  • 마상준;장필성;신진용;남관우
    • 한국터널지하공간학회 논문집
    • /
    • 제10권1호
    • /
    • pp.17-24
    • /
    • 2008
  • 국내에서 대부분 시공되어지고 있는 현장타설 콘크리트 라이닝은 여러 가지가 문제점을 나타내고 있다. 그 중에 특히 라이닝의 균열 발생은 사회적 및 경제적인 문제로까지 제기되고 있으며 라이닝의 미관뿐만 아니라 안정성에도 영향을 미치게 되므로 막대한 보수보강 공사비의 지출을 유발해 국가 예산을 소모시키고 있다. 국내 콘크리트 2차 제품 생산업체의 생산기술은 아직 선진국 수준에 미치지 못하며, 고품질 제품 생산에 있어 가장 중요한 증기양생 방법 또한 규정되어 있지 않은 실정이다. 본 연구에서는 터널용 PC 패널의 증기양생조건 중 전양생시간, 온도상승구배를 달리하여 물리적 특성을 검토하였다. 시험결과, 고강도 PC패널의 전양생시간은 최소 1시간 이상이 바람직하였으며 온도상승구배는 최대 $20^{\circ}C$가 물리 역학적으로 가장 우수한 성능을 나타내었다.

  • PDF