• Title/Summary/Keyword: concrete hydration

Search Result 1,005, Processing Time 0.029 seconds

Properties of Autogenous Shrinkage according to Hydration Heat Velocity of High Strength Concrete Considering Mass Member (매스부재를 고려한 고강도콘크리트의 수화발열상승속도 조절에 따른 자기수축 특성)

  • Koo, Kyung-Mo;Kim, Gyu-Yong;Hong, Sung-Hyun;Nam, Jeong-Soo;Shin, Kyoung-Su;Khil, Bae-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.369-376
    • /
    • 2012
  • In this study, to reduce the hydration heat velocity (HHV) of high-strength mass concrete at early ages, phase change materials (PCM) that could absorb hydration heat were applied, and the changes in autogenous shrinkage were investigated, as well as the relationship between the hydration temperature and autogenous shrinkage. The acceleration of the cement hydration process by the PCM leads to an early setting and a higher development of the compressive strength and elastic modulus of concrete at very early ages. The function of PCM could be worked below the original melting point due to the eutectic effect, while the hydration temperature and HHV of high-strength mass concrete can be decreased through the use of the PCM. A close relationship was found between the hydration temperature and autogenous shrinkage: the higher the HHV, the greater the ultimate autogenous shrinkage.

The statistical method for quantitative analysis of hydration heat and autogenous shrinkage of concrete (콘크리트 수화발열 및 자기수축 특성의 정량적 분석을 위한 통계적 방법)

  • Lee, Eui-Bae;Lee, Hyung-Jun;Koo, Kyung-Mo;Na, Chul-Sung;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.645-648
    • /
    • 2008
  • In this study, to evaluate the correlation between hydration heat and autogenous shrinkage of high strength concrete in early age, statistical method present numerically hydration heat and autogenous shrinkage was studied. First of all, hydration heating velocity and autogenous shrinking velocity as quantitative coefficients which represent the main properties of hydration heat and autogenous shrinkage were proposed. Two coefficients were calculated by statistical analysis and were equal with the regression coefficient. To verify the validity of the proposed statistical analysis method, data of hydration heat and autogenous shrinkage gathered by a real experiment were analyzed by it. In results, properties of hydration heat and autogenous shrinkage of high strength concrete in early age were analyzed quantitatively. Also evaluation and comparison of the correlation between hydration heat and autogenous shrinkage with numerical value were possible.

  • PDF

Analysis of Early-Age Concrete Through Instrumentation During Construction (시공중 계측을 통한 초기 콘크리트의 거동분석)

  • 오병환;최성철;신준호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.795-798
    • /
    • 2002
  • Recently. the properties of early-age concrete are increasingly important because these properties directly influence the behavior of early-age concrete structures including stress and cracking behavior. Nevertheless, the studies on early-age concrete are limited to strength and temperature development. The purpose of present study is to propose a simple and rational method which can predict the stress and strain behavior of young age concrete. A series of test have been done to measure the temperature development, strains and stresses in concrete members. The concept of equivalent age was used to define the degree of hydration and this degree of hydration was used to calculate the strength and elastic modulus. The present study indicates that the calculated stresses correlate fairly well with measured stresses. The consideration of critical degree of hydration in calculating stresses gives more accurate results. The present study provides useful method and data in evaluating early-age behavior of concrete structure.

  • PDF

The Experimental Study on the Heat Hydration Properties of Concrete According to Binder Conditions (결합재 조건에 따른 콘크리트의 수화발열특성에 관한 실험적 연구)

  • Jo Hyun Tae;Choi Yong Hyun;Kim Sung;Ryu Deuk Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.595-598
    • /
    • 2005
  • Recently, owing to the development of industry and the improvement of building techniques, the concrete structure is becoming larger and higher. In hardening these large concrete, the heat of hydration gives rise to considerable thermal stress depending on the size and environmental condition of concrete, which might cause thermal cracking. Especially, the crack may cause severe damage to the safety and the durability of concrete structure. This study is investigated the thermal properties of concrete according to several binder conditions, such as OPC, Belite rich cement(BRC), slag cement(SC), blast furnace slag (BFS) added cement, fly ash added cement and BFS-fly ash added cement. As a result of this study, the concrete made with BRC, fly ash($25\%$) added cement and BFS($35\%$)-fly ash($15\%$) added cement gets superior effect in the control of heat hydration.

  • PDF

An Experimental Study on the Properties of Ultra Low Heat Mass Concrete Containing Limestone Powder (석회석미분말을 혼입한 초저발열 매스콘크리트의 특성에 관한 연구)

  • 하재담;김동석;김태홍;이종열;권영호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1175-1180
    • /
    • 2000
  • Recently, the crack of concrete induced by the heat of hydration of cement is a serious problem for more greater, special and higher strength of concrete structures. The increasing concrete's temperature is mainly caused by the heat of hydration of cement and so, to control the thermal stress of concrete structure is desirable to use low heater material of hydration. There are many methods to diminish the increasing of concrete temperature such as using of low heat cement, addition of fly-ash, application of pre-cooling, etc., and in this study, we evaluate the heating and mechanical properties of ultra low heat mass concrete using Low Heat Portland(KS Type IV) cement with 30% of limestone powder. The results of this study will be applied to side wall and bottom of No. 15 and 16 of underground LNG tank in Inchon.

An Analysis of the Crack Cause of Concrete Faced Rockfill Dam (사력댐 차수벽 콘크리트의 균열원인 분석)

  • Chae, Young-Suk;Lee, Myeong-Gu
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.133-137
    • /
    • 2012
  • Cracking may be used to help predict the cause of deterioration of concrete, since in many cases characteristic cracking patterns are produced. The purpose of this paper is an analysis of the crack cause occurred in concrete faced rockfill dams. We analyzed the concrete placement methods, cracking pattern, the inspection of crack depth by the ultrasonic pulse velocity method, and the measurement of heat of hydration, environmental condition, and so on. In this study, the crack cause of concrete faced rockfill dam is the wrong method of concrete placement, high temperature difference by cement of heat of hydration and concrete of drying shrinkage.

The Use of Semi-Adiabatic Calorimetry for Hydration Studies of Cement Paste

  • Chung, Chul-Woo;Kim, Ji-Hyun;Lee, Soo-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.185-192
    • /
    • 2016
  • The semi-adiabatic calorimetry technique is a robust and easy technique that can be used to measure the temperature rise of concrete. This method is often used for investigating the maturity of concrete, as well as to predict maximum temperature rise of mass concrete using various heat loss compensating models. Semi-adiabatic calorimetry can also be used for predicting setting time of concrete. However, it has seldom been used to investigate the hydration characteristics of various cement paste samples. In this research, semi-adiabatic calorimetry and X-ray diffraction methods were used to investigate the hydration characteristics of 3 different ASTM type I Portland cements. First derivative of temperature rise (dT/dt) curve was used to isolate individual peaks. Based on the results of the experiments, a combination of dT/dt curve with XRD could be used to successfully identify hydration at a specific time period, showing its potential to be used as an alternative tool for hydration studies of cement-based materials.

The simulation of hydration of Portland cement blended with chemical inert filler

  • Xiaoyong, Wang;Lee, Han-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1041-1044
    • /
    • 2008
  • The addition of chemical inert filler in blended cement, such as limestone or chemical inert silica fume, will produce a physical effect on cement hydration. Due to the high surface area of inert filler in the mixtures, it provides sites for the nucleation and growth of hydration products, thus improving the hydration rate of cement compounds and consequently increasing the strength at early age. This paper proposes a model of hydration of Portland cement blended with chemical inert filler. This model considers the influence of water to cement ratio, cement particle size, cement composition and addition of chemical inert filler on hydration. The heat evolution, degree of hydration and porosity are obtained as accompanied results in hydration process. The prediction results agree well with experiment results.

  • PDF

An Experimental Study on Hydration Heat Control in The Mass Concrete Using Oscillating Capillary Tube Heat Pipe (진동세관형 히트파이프(OCHP)를 이용한 매스콘크리트의 수화열 제어에 관한 실험적 연구)

  • Beak, Dong-Il;Kim, Myung-Sik;Lee, Moon-Sik;Kim, Kang-Min;Yum, Chi-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.409-412
    • /
    • 2006
  • In process of reinforced concrete(RC) box structure, the heat of hydration may cause serious thermal cracking problems. In order to eliminate hydration heat of mass concrete, this paper reports results of hydration heat control in mass concrete using the OCHP(Oscillating Capillary tube Heat Pipe). Recently OCHP is drawn special attention from these points of low cost as well as short construction schedule for the manufacturing of heat exchanger, flexibility, simplification and high performance. There were three RC box molds$(1.2{\times}1.2{\times}1.2m)$ which shows a difference as compared with each other. One was not equipped with OCHP. While others were equipped with OCHP and these were cooled with air natural convection and spraying water respectively. The OCHP was composed of copper pipe with 12 turns(O.D : 4mm, I.D : 2.8mm). The working fluid was R-22 and its charging ratio was 30(Vol. %). In order to analyze the distribution of temperature and index figure of thermal crack in sequential placement of mass concrete, we used HYCON of computer program. As a result of the experiment, the peak temperature decreased about $15.6\sim23.4^{\circ}C$ than the general specimen and the probability of thermal crack generated in mass concrete decreased up to 0%.

  • PDF

A Study on Field Applications of Hydration Heat Control in the Mass Concrete Using Oscillating Capillary Tube Heat Pipe (OCHP를 이용한 매스콘크리트 수화열 제어의 현장적용에 관한 연구)

  • Yum, Chi-Sun;Bae, Won-Mahn;Kim, Myung-Sik;Beak, Dong-Il;Kim, Kang-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.413-416
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper reports results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several RC box molds which shows a difference as compared with each other. One was not equipped with OCHP. The others were equipped with OCHP. All of them were cooled with natural air convection. The OCHP was composed of copper pipe with 11 turns(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $55^{\circ}C$ in the winter without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.75 to 1.47.

  • PDF