• Title/Summary/Keyword: concrete filled steel sections

Search Result 66, Processing Time 0.029 seconds

A Study on the Load Carrying Capacity and Energy Absorption Capacity of the Concrete Filled Steel Tube Column (콘크리트충전 강관기둥의 내력 및 변형 능력에 관한 연구)

  • Chung, Kyung Soo;Choi, Sung Mo;Kim, Dong Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.121-128
    • /
    • 1997
  • It has been reported by the existing papers that the ultimate load capacity and energy absorption capacity of the CFST column are considerably higher than those resulting from a simple addition of the capacities of the concrete and the steel tube. It is normally believed that the confined effect for the infilled concrete due to the hoop tension of steel at the parameter of cross sections can remarkably improve the ductility and energy absorption capacities of the CFST columns. This paper provides the results of a study on the load-carrying capacities and energy absorption capacities of the CFST columns, a numerical analysis method, i. e. N-M interaction curves and Moment curvature relationships. The numerical approaches are verified by comparing with the existing test results and the circular and square steel tube sections are selected to clarify the amount of confinement effects to improve the ultimate deformable capacity(a ultimate strain value) of the infilled concrete. Then, an adequate value of the ultimate strain of the infilled concrete and an equation of the ultimate capacity of the CFST column are suggested.

  • PDF

Limitations on the Width-to-Thickness Ratio of Rectangular Concrete-Filled Tubular (CFT) Columns (콘크리트 충전 각형강관 기둥의 폭두께비 제한에 관한 연구)

  • Choi, Young-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.451-458
    • /
    • 2012
  • The concrete-filled steel tube (CFT) that has an excellent performance can be more economically used when the steel tube has a large width-to-thickness ratio. However, the international provisions such as American Institute of Steel Construction (AISC) limit the use of a slender plate in CFT members, resulting in a less optimal use of CFT. This study verifies the post buckling strength of CFT columns through the experimental program for Hollow Steel Sections (HSS) and CFTs with a with-to-thickness ratio ranged 60 to 100. The study also proposes a relaxed limitations of with-to-thickness ratio compared to the one specified in the current standards.

Performance of composite frame consisting of steel beams and concrete filled tubes under fire loading

  • Shariati, Mahdi;Grayeli, Mohammad;Shariati, Ali;Naghipour, Morteza
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.587-602
    • /
    • 2020
  • In recent years, the composite columns have been widely used in the structures. These columns are mainly used to construct the structures with a large span and high floor height. Concrete filled tubes (CFTs) are a type of composite column, which are popular nowadays due to their numerous benefits. The purpose of this study is to investigate such frames at elevated temperatures. The method used in this research is based on section 2.2 of Eurocode 4. First, for the verification purpose, a comparison was made between the experimental results and the numerical model of the concrete filled tube. Then a composite frame was analyzed under fire temperature with different parameters. The results showed that the failure time decreased with increasing the friction of different models. Moreover, investigation of the concrete moisture content revealed that an increase in the concrete moisture content from 3% to 10% led to extended failure time for different models. For instance, in the second frame model, the failure time has increased up to 8%.

In-Plane Stability of Concrete-Filled Steel Tubular Parabolic Truss Arches

  • Liu, Changyong;Hu, Qing;Wang, Yuyin;Zhang, Sumei
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1306-1317
    • /
    • 2018
  • For determining the in-plane buckling resistance of a concrete-filled steel tubular (CFST) arch, the current technical code GB50923-2013 specifies the use of an equivalent beam-column method which ignores the effect of rise-to-span ratio. This may induce a gap between the calculated result and actual stability capacity. In this study, a FE model is used to predict the buckling behavior of CFST truss arches subjected to uniformly distributed loads. The influence of rise-to-span ratio on the capacity of truss arches is investigated, and it is found that the stability capacity reduces as rise-to-span ratio declines. Besides, the calculations of equivalent slenderness ratio for different truss sections are made to consider the effect of shear deformation. Moreover, based on FE results, a new design equation is proposed to predict the in-plane strength of CFST parabolic truss arches under uniformly distributed loads.

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • v.25 no.4
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.

Second-order inelastic dynamic analysis of cable-stayed bridges using rectangular concrete-filled steel tubular columns

  • Van-Tuong Bui;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • v.52 no.6
    • /
    • pp.673-693
    • /
    • 2024
  • An advanced numerical method is proposed in this paper for the second-order inelastic dynamic analysis of cable-stayed bridges using rectangular concrete-filled steel tubular (CFST) columns under earthquake loadings for the first time. The proposed method can exactly predict the nonlinear response of the bridges by using only one element per member in simulating the structural model. This comes from considering both the geometric and material nonlinearities in a fiber beam-column element and a catenary cable element. In the fiber beam-column element, the geometric nonlinearities are captured by applying the stability functions, whereas the material nonlinearities are evaluated by tracing the uniaxial cyclic stress-strain curves of each fiber on the cross-sections, which are located at the integration points along the member length. A computer program was developed based on Newmark's average acceleration algorithm to solve the nonlinear equations of motion. The accuracy and computational efficiency of the proposed program were verified by comparing the predicted results with the experimental results, and the results obtained from the commercial software SAP2000 and ABAQUS. The proposed program is promising as a useful tool for practical designs for the nonlinear inelastic dynamic analysis of cable-stayed bridges.

Predicting the axial compressive capacity of circular concrete filled steel tube columns using an artificial neural network

  • Nguyen, Mai-Suong T.;Thai, Duc-Kien;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • v.35 no.3
    • /
    • pp.415-437
    • /
    • 2020
  • Circular concrete filled steel tube (CFST) columns have an advantage over all other sections when they are used in compression members. This paper proposes a new approach for deriving a new empirical equation to predict the axial compressive capacity of circular CFST columns using the Artificial Neural Network (ANN). The developed ANN model uses 5 input parameters that include the diameter of circular steel tube, the length of the column, the thickness of steel tube, the steel yield strength and the compressive strength of concrete. The only output parameter is the axial compressive capacity. Training and testing the developed ANN model was carried out using 219 available sets of data collected from the experimental results in the literature. An empirical equation is then proposed as an important result of this study, which is practically used to predict the axial compressive capacity of a circular CFST column. To evaluate the performance of the developed ANN model and the proposed equation, the predicted results are compared with those of the empirical equations stated in the current design codes and other models. It is shown that the proposed equation can predict the axial compressive capacity of circular CFST columns more accurately than other methods. This is confirmed by the high accuracy of a large number of existing test results. Finally, the parametric study result is analyzed for the proposed ANN equation to consider the effect of the input parameters on axial compressive strength.

Structural response of rectangular composite columns under vertical and lateral loads

  • Sevim, Baris
    • Steel and Composite Structures
    • /
    • v.25 no.3
    • /
    • pp.287-298
    • /
    • 2017
  • The present study aims to determine the structural response of full scaled rectangular columns under both of vertical and lateral loads using numerical methods. In the study, the composite columns considering full concrete filled circular steel tube (FCFRST) and concrete filled double-skin rectangular steel tube (CFDSRST) section types are numerically modelled using ANSYS software. Vertical and lateral loads are applied to models to assess the structural response of the composite elements. Also similar investigations are done for reinforced concrete rectangular (RCR) columns to compare the results with those of composite elements. The analyses of the systems are statically performed for both linear and nonlinear materials. In linear static analyses, both of vertical and lateral loads are applied to models as only one step. However in nonlinear analyses, while vertical loads are applied to model as only one step, lateral loads are applied to systems as step by step. The displacement and stress changes in some critical nodes and sections and contour diagrams are reported by graphs and figures. At the end of the study, it is demonstrated that the nonlinear models reveal more accurate result then those of linear models. Also, it is highlighted that composite columns provide more and more safety, ductility compared to reinforced concrete column.

Influence of slenderness on axially loaded square tubed steel-reinforced concrete columns

  • Yan, Biao;Gan, Dan;Zhou, Xuhong;Zhu, Weiqing
    • Steel and Composite Structures
    • /
    • v.33 no.3
    • /
    • pp.375-388
    • /
    • 2019
  • This paper aims to investigate the axial load behavior and stability strength of square tubed steel-reinforced concrete (TSRC) columns. Unlike concrete filled steel tubular (CFST) column, the outer steel tube of a TSRC column is mainly used to provide confinement to the core concrete. Ten specimens were tested under axial compression, and the main test variables included length-to-width ratio (L/B) of the specimens, width-to-thickness ratio (B/t) of the steel tubes, and with or without stud shear connectors on the steel sections. The failure mode, ultimate strength and load-tube stress response of each specimen were summarized and analyzed. The test results indicated that the axial load carried by square tube due to friction and bond of the interface increased with the increase of L/B ratio, while the confinement effect of tube was just the opposite. Parametric studies were performed through ABAQUS based on the test results, and the feasibility of current design codes has also been examined. Finally, a method for calculating the ultimate strength of this composite column was proposed, in which the slenderness effect on the tube confinement was considered.

Finite Element Analysis of Inelastic Behavior of SRC Composite Piers (SRC 합성교각의 비탄성거동에 대한 유한요소해석)

  • Shim, Chang-Su;Han, Jung-Hoon;Park, Chang-Kyu;Chung, Young-Soo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.269-275
    • /
    • 2006
  • In the design of bridge piers in seismic area, the ductility requirement is one of the most important design criteria. In order to enhance the seismic performance of RC columns, it is necessary to make the ductility of columns larger by covering RC columns with steel tubes or confining RC columns by arranging transverse reinforcement such as hoop ties closely. Concrete encased composite columns can be utilized for bridge piers especially in seismic area. In this paper, finite element analyses are performed to study the nonlinear behavior of concrete encased composite columns with single core steel or multiple steel elements under static and quasi-static loads. The cross-sections of these specimens ate composed of concrete-encased H-shaped structural steel columns and a concrete-encased circular tube with partial in-filled concrete. Test parameters were the amount of the transverse reinforcement, encased steel member, and loading axis. Through the comparison between FE analyses and test results, adequate material models for confined concrete and unconfined concrete ate investigated. After getting the proper analysis models for composite columns, several parameters are considered to suggest design considerations on the details of composite piers.

  • PDF