• 제목/요약/키워드: concrete durability.

검색결과 2,147건 처리시간 0.028초

표면 마감재를 시공한 RC조 아파트의 확률론적 탄산화 평가 연구 (A study on the Probabilistic Carbonation Progress for Existing RC Structure Apartment by Surface Finishing Materials)

  • 이형민;민상호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.7-8
    • /
    • 2017
  • As the importance of maintenance of reinforced concrete structure recently has emerged, the attention of durability of structure has been increasing. There are many studies about durability decline especially due to the carbonation. In order to study carbonation progress after surface repair of carbonated concrete, each carbonation penetration velocity from different repair materials of concrete structure is compared through the experiment of carbonation accelerating CO2 concentration to 5%. As carbonation infiltration progress is predicted through this study, the counterplan of service life evaluation will be prepared on selection of repair materials of concrete structure.

  • PDF

차수벽 콘크리트의 섬유보강 및 팽창제 혼입에 따른 소성수축균열 제어특성에 관한 실험적 연구 (An Experimental Study on Plastic Shrinkage of fiber and Expansive Additive for Face Slab Concrete)

  • 김완영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.679-682
    • /
    • 2005
  • The effects of substituting cement with fiber addition(poly vinyl alcohol), fly ash and Expansive Additive on the control of microcrack and enhanced durability performance of face slab concrete in concrete-faced rockfill dam was studied experimentally The laboratory test results shown that the mixture of fiber containing concrete and of fly ash replacement of concrete to be more effective than expansive additive concrete in the crack control and mechanical performance.

  • PDF

해양환경하에 노출된 콘크리트 구조물의 침식평가 (Evaluation on Deterioration of Concrete Structure under Marine Environment)

  • 문한영;김성수;김홍삼;이승태;권태석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.399-402
    • /
    • 2000
  • When concrete structures are built in marine environment, they may be deteriorated and have the poor durability and quality caused by steel corrosion or by chemical attack of magnesium or sulfate ions. Especially, Mg ions contained in seawater make concrete surface weaken by chemical reaction with $Ca(OH)_2$ In this study, a concrete structure built in 1947 was investigated to estimate the factors, especially chemical attack, which can cause concrete to deteriorate. Furthermore, the instrumental analysis methods such as XRD and ESEM were performed to find the reactants in concrete under marine environment.

  • PDF

방식재료의 내부식 성능에 관한 물성연구 (Experimental Investigation of Properties for Corrosion resistance of Corrosion Inhibitors)

  • 이상엽;김양현;한만엽;엄주용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.257-262
    • /
    • 1997
  • Reinforced concrete structures built on the seashore or in seawater are damaged from saltwater which cause to accelerate corrosion of reinforcing steel in concrete. Therefore, Corrosion of steel reinforcement of concrete structures become more and more serious, and prediction of service lives of concrete structures considering steel corrosion is needed much more. this research is to investigate basic physical properties of various corrosion inhibitors and to evaluate their corrosion resistance in concrete. The object of this study is develop appropriate corrosion protection systems so as to enhance the durability of concrete.

  • PDF

폴리머 침투콘크리트 보의 거동 (Behavior of Polymer-Impregnated Concrete Beams)

  • 변근주;이상민;유동우;이용진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.67-73
    • /
    • 1992
  • Polymer-Impregnated Concrete(PIC) is a new polymer-concrete composite material which consist of basic cement concrete and polymer. The mechanical properties and behavior of PIC depend on the type of polymers and the impregnation techniques. In general, the polymer impregnation can improve the strength, durability and ductility of normal concrete. The objective of this study is to develop the analytical procedure for analyzing the structural responces of polymer-impregnated concrete beams with different polymer loading by using finite element method on the basis of experimental results.

  • PDF

고강도용 콘크리트의 온도상승 저감대책 (The Reduction of Temperature Rise in High Strength Concrete)

  • 문한영;문대중;하상욱;서정우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.133-139
    • /
    • 1996
  • As construction technology advances, most of civil engineering structures are becoming larger and taller. Therefore, high strength concrete is necessary for them. For high strength concrete, it needs a large amount of unit cement content and low water-cement ratio inevitably, so that a large amount of heat occurs in concrete. The thermal cracks make the durability and quality of concrete structures become worse, result from temperature rise and thermal stress due to heat of hydration. In this study, the proposal of using ground granulated blast furnace slag, fly ash and chemical admixtures was investigated to decrease the temperature rise of concrete.

  • PDF

지하철 콘크리트 BOX구조물의 내구성설계에 대한 연구 (A Study of Durability Design in the Subway Concrete Box Structure)

  • 권영찬;김은겸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.940-956
    • /
    • 2004
  • In the course of studying the design of securing the 100-year-long durability of 100 years the subway structure according to the requested service by the Seoul Metropolitan Subway Construction Headquarters, we analyzed 14 construction sites adopting the durability design in subway line No. 9 and concluded as follows: 1. When comparing with 158, the environment index presented for securing 100-year-long durability of subway structure in subway line No. 9, the index of durability was verified as 159.7$\~$179.8 2. When examining the increase value of durability index, we verified that the constructors didn't make various choices in method but they employed the uniformly selected system. 3. Under consideration of the bid form, the construction under bid contract in bulk gave the impacts on the construction cost with attention to selection of the durability index, while the construction under alternative contract in bid adopted uniformly the standard presented by the ordering party.

  • PDF

고성능유동화제가 콘크리트의 공학적 특성에 미치는 영향 (I) (A Study on the Effects of Superplasticizers on the Engineering Preperties of Plain Concrete (I))

  • 박승범;이보성
    • 한국농공학회지
    • /
    • 제26권3호
    • /
    • pp.68-80
    • /
    • 1984
  • This study was attempted in order to investigate the effects of superplasticizers on fresh and hardened concrete. The experimental program included tests on the slump and slump loss, bleeding, time of set, air content, the compacting, factor Vee Dee, compressive strength, tensile and flexural strength, permeability, shrinkage and freege-thaw durability. The major conclusions that can be drawn on the study are as follows. 1. Superplasticizers were observed to have an appreciable fluidifying action in fresh concrete so that tinder appropriate conditions, they either considerably improved its workability or permitted a water reduction of at least 8-12% to be made while maintaining normal workability. 2. The bleeding ratios of base and S,P. Concrete were much lower than those of the conventional concrete. Differences between the base and S.P. Concrete were insignifician. 3. The setting time was the longest for conventionla concrete, followed by S.P. concrete and base concrete in thatorder. And AE water reduction admixtures showed an appreciable influence on the setting and hardening characteristics of concrete and prolonged the stiffening times. 4. The high initial slump values of S.P. concrete generally decreased rapidly with increased standing time. CF values showed increasing tendencies with the increase of S.P. content, and excessive addition of S.P. caused the segregation of fresh concrete, resulting in its rejection. 5. Though there was a slight increase in strength, no significant differences are observed between base and S.P. concrete in terms of the compressive, tensile and flexural strength. 6. The permeability of S.P. concrete was significantly less than that of the conventional concrete, and the shrinkage of S.P. concrete was considerably smaller than that of the conventional concrete, but there were no significant differences between base and S.P. concrete. 7. Compared to base concrete, S.P. concrete without entrained air tended to slightly increase freeze-thaw durability, and S.P. concrete with an appropriate entrained air gave satisfactory resistance to freezing and thawing.

  • PDF