• Title/Summary/Keyword: concrete crack evaluation

Search Result 364, Processing Time 0.024 seconds

An Evaluation of Plastic and Early Dry Shrinkage of Fiber Reinforced Concrete Using Recycled Aggregate (순환잔골재를 활용한 섬유 보강 콘크리트의 소성 및 초기 건조수축평가)

  • Park, Yun-Mi;Kim, Young-Duck;Kim, Young-Sun;Kim, Ho-Dong;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.937-940
    • /
    • 2008
  • Recently, the recycling and reusing of construction and demolition waste concrete is urgently required because generation quantity of construction and demolition waste concrete is greatly increased according to the rapid increasing of urban redevelopment project. On the other hand, the problem solution for demand and supply unbalance of fine aggregate is urgently required because of the restriction of collecting sea fine aggregate by intensification of environment influence evaluation and the shortage of river fine aggregate. but a quality of aggregate as building structure is not demonstrated. Therefore it is the objective of this study to estimate plastic and early dry shrink crack of fiber reinforced concrete using a recycled aggregate by plat-ring test and mock-up test of exposure to the air. as a result, in case of plat- ring test, developing crack is wider using recycled aggregate concrete than natural aggregate concrete, is wider using fiber reinforced concrete than non fiber. in case of mock-up test of exposure to the air, it is similar to plat-ring test.

  • PDF

A Study on the Properties of Promoted High Durability Concrete Applied to Coastal Landfill Underground Structures (고내구성 콘크리트(PHDC)의 해안가 매립지 지하구조물의 현장적용 특성에 관한 연구)

  • Kim, Woo-Jae;Khil, Bae-Su;Kim, Do-Su;Kim, Sung-Su;Jung, Sang-Jin;Lee, Han-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.153-154
    • /
    • 2009
  • This study examined the field applicability of promoted high durability concrete (PHDC) developed for improving the chloride penetration resistance of coastal landfill underground structures. PHDC was found superior to conventional concrete containing slag in watertightness, crack resistance, and chloride penetration resistance required in coastal landfill underground structures. It was also more workable in field application, and easier to control the quality. This study investigated the strength development, crack resistance, and chloride penetration resistance of PHDC, and performed life evaluation of underground concrete structures of coastal landfill using the Life 365 program.

  • PDF

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Crack Repairing Material using in Wet Environment Structure (습윤 환경 구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구)

  • 강효진;우영제;강호경;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.43-48
    • /
    • 2002
  • Since the basement building like the communication hole and etc. is built under the ground where it is pressed by the water, the leakage happens due to the dried-shrinking crack, the sinking crack, the creation of the work-joint of the building and etc. caused by the character of the material and construction way of the reinforced concrete building. Especially, a lot of repair for the leakage cannot help but being taken in temporary way without any noticeable countermeasure. Therefore, this kind of repair is socially criticized many times that this is defective construction even if this costs a lot. The fundamental reason of the above mentioned symptoms can be found in the creation of the work-joint caused by the character of the concrete building, the limitation of the physical performance of the existing water-proof and repair material, the limitation of the construction, the limitation of the physical sustaining performance of the concrete building, the limitation(heat-injury, deterioration) of the constancy of the durability caused by aging and etc. Therefore, in this study, we would like to present the better understanding on the water-proof seal relating to the application at the spot and its test evaluation related data since the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is rising a lot to regulate the water-proof technology and the leakage repair technology in accordance with the growth of the demand on the facility.

  • PDF

Evaluating the Depth of a Surface-opening Crack in Concrete Slabs using Surface wave Measurements (표면파 측정을 통한 콘크리트 슬래브의 표면균열 깊이 측정)

  • Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.104-112
    • /
    • 2015
  • Non-contact surface wave transmission (SWT) measurements are used to evaluate the depth of a surface-breaking crack in concrete slabs. The author propose a measurement model that includes an appropriate configuration of the source and receivers, and a transmission function for the given configuration. A series of numerical simulations using a 3D finite element model is used to obtain the transmission function. Then, validity of a proposed model is verified through experimental studies. Two air-coupled sensors are used to measured surface waves across surface-breaking cracks with varying depths from 0mm to 100mm with intervals of 10mm in a concrete slab ($1500{\times}1500{\times}180mm^3$) in laboratory. As a result, the proposed method is demonstrated as to be effective for charactering the depth of a surface-breaking crack in concrete bridge deck with an average error of 10%. A discussion on practical applications of the proposed method is also included in this article.

Correlation Analysis Between Crack and TQI in RC Slab Track (철도콘크리트 슬래브 궤도상의 균열과 TQI 상관성 분석)

  • Kwon, Sae Kon;Park, Mi Yun;Kim, Doo Kie;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.71-79
    • /
    • 2012
  • Recently, in the total railroad construction field, the concrete slab track is adapted, not ballast track. Because the ballast track have the characteristics doing the ongoing maintenance and difficult to handle increasing maintenance costs, eventually the concrete slab track is selected as an alternative. However, owing to the hydration heat reactions and temperature affected shrinkage cracks related to concrete itself, a variety of studies to solve maintenance problems related to concrete slab track are underway. This study analysed characteristics of TQI values evaluating the track irregularity, searched the relationship between crack progress and TQI, and then evaluated of the correlation between the two values. Through this method, there is a need to complete the problems of the current method, only TQI is the main decision making tool in track maintenance, and also the need for the development of evaluation index considering the crack.

A Study on the Development of Flat-Ring Type Restrained Test Method and Performance Evaluation for Evaluating Shrinkage Cracking Properties of Concrete in Early Age (콘크리트 초기 수축균열특성 평가를 위한 판상-링형 구속시험방법의 성능평가에 관한 연구)

  • Kim, Gyu-Yong;Choi, Hyeong-Gil;Lee, Eui-Bae;Nam, Jeong-Soo;Han, Min-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.188-196
    • /
    • 2009
  • In Concrete, shrinkages occur like plastic shrinkage and drying shrinkage in the early age because of evaporation and transfer of moisture. Within the country, the crack test standardized by KS is used to test the drying shrinkage of the concrete by using the restricted drying shrinkage of Dumbbell type mold, but this test is for the cracking-point and the restricted shrinkage stress. Thus it is difficult to valuate the crack quantitative test. In this study, it is intended to develop the Flat-ring type restrained test method for the shrinkage deformation movement of the concrete and to provide the quantitative data for evaluating the cracks in concrete. And it suggest the proper specimen diameter and quantitative test method about shrinkage crack properties on Flat-ring type restrained test method. And Verified the suitability.

Evaluation of Flexural Performance of RC Beams Using Polymer Cementitous Mortar (폴리머시멘트 모르터를 이용한 RC 보의 휨 성능평가)

  • 양동석;고원준;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.479-484
    • /
    • 2000
  • An experimental study to investigate the structural performance of reinforced concrete beams repaired by Polymer Cementitous Mortar in the tension zone is described. Preliminary trials with beams in which beams tensile reinforcing steel was exposed over 100%, 80% and 60% of their length have led to tests on $5\times25$cm beams over a 200cm span to examine the experimental parameter. Attention is concentrated upon overall bending capacity, deflection and crack development of repaired beams.

  • PDF

Evaluation of Effective Toughness of Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트의 유효인성 평가)

  • 구봉근;정경섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 1992
  • 본 연구는 인성지수에 의하여 섬유보강 콘크리트의 인성을 평가하는 기존의 여러 가지 방법을 검토하는, 하중-처짐곡선에서 초기균열시까지의 여러 가지 다른 곱으로 나타내어지는 방법의 불합리성을 지적하였다. 이를 위하여 본 연구에서는 유효인성이라고 부르는 새로운 방법을 강섬유 보강콘크리트의 인성을 평가하는데 제안하였다. 이는 초기균열을 가진 3점 휨강도 시험에 의한 하중-처짐곡선에서 지간의 1/150까지의 면적을 ligament면적으로 나눈값으로 나타낸다. 이 방법을 사용하여 강섬유 보강 고강도 콘크리트 인성특성을 검토한 결과 기존의 방법보다 더 효과적으로 인성을 평가할 수 있었다.

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

Computer modeling and analytical prediction of shear transfer in reinforced concrete structures

  • Kataoka, Marcela N.;El Debs, Ana Lucia H.C.;Araujo, Daniel de L.;Martins, Barbara G.
    • Computers and Concrete
    • /
    • v.26 no.2
    • /
    • pp.151-159
    • /
    • 2020
  • This paper presents an evaluation of shear transfer across cracks in reinforced concrete through finite element modelling (FEM) and analytical predictions. The aggregate interlock is one of the mechanisms responsible for the shear transfer between two slip surfaces of a crack; the others are the dowel action, when the reinforcement contributes resisting a parcel of shear displacement (reinforcement), and the uncracked concrete comprised by the shear resistance until the development of the first crack. The aim of this study deals with the development of a 3D numerical model, which describes the behavior of Z-type push-off specimen, in order to determine the properties of interface subjected to direct shear in terms cohesion and friction angle. The numerical model was validated based on experimental data and a parametric study was performed with the variation of the concrete strength. The numerical results were compared with analytical predictions and a new equation was proposed to predict the maximum shear stress in cracked concrete.