• 제목/요약/키워드: concentration ratio

검색결과 6,418건 처리시간 0.038초

화진포호의 수환경변화에 관한 연구 (The Study of Water Environment Variations in Lake Hwajinpo)

  • 허우명;최상규;곽성진;발데브;이은주
    • 생태와환경
    • /
    • 제44권1호
    • /
    • pp.9-21
    • /
    • 2011
  • 화진포호에서 장기간의 수환경변화를 알아보기 위해 2000년부터 2008년까지 염분, 용존산소, 총인 및 총질소등 이 화학적 조사를 하였으며, 동식물플랑크톤은 2007년과 2008년에 조사하였다. 화진포호에서 2000년부터 2008년까지 조사된 수질자료를 보면 수온, 염분, 투명도, COD 및 DO는 각각 $2.8{\sim}29.4^{\circ}C$, 0.23~41.8‰, $0.2{\sim}2.8\;m$, $0.2{\sim}20.2\;mg\;L^{-1}$$0.1{\sim}17.4\;mg\;L^{-1}$의 범위로 평균은 각각 $18.0^{\circ}C$, 15.7‰, 0.7 m, $5.7\;mg\;L^{-1}$$8.0\;mg\;L^{-1}$이었다. Chl.${\alpha}$$0.3{\sim}242.5\;{\mu}g\;L^{-1}$으로 평균 $32.8\;{\mu}g\;L^{-1}$이었다. TP와TN는 각각 $0.024{\sim}0.869\;mg\;L^{-1}$(평균 0.091) 및 $0.240{\sim}5.310\;mg\;L^{-1}$(평균 1.235)의 범위를 보였다. TN/TP 비는 평균 16.4이었다. COD, TP, TN 및 Chl.${\alpha}$의 연변화를 보면 COD는 2000년에 $4.83m\;mg\;L^{-1}$이었으나 2008년에는 $1.80\;mg\;L^{-1}$로 매년 $0.34\;mg\;L^{-1}$ 감소를 보였다. TP는 2000년에 $0.07\;mg\;L^{-1}$이였으나 2008년에는 $0.05\;mg\;L^{-1}$로 차츰 감소하였다. TN은 2000년에 $1.54\;mg\;L^{-1}$이었으니 2008년에는 $0.77\;mg\;L^{-1}$로 매년 $0.09\;mg\;L^{-1}$ 감소하였다. Chl.${\alpha}$은 2000년에 $46.30\;{\mu}g\;L^{-1}$이었으나 2008년에는 $5.78\;{\mu}g\;L^{-1}$로 매년 $4.50\;{\mu}g\;L^{-1}$씩 감소하였다. 화진포호의 Orgnic-N, $NO_3$-N, $NH_3$-N 및 $NO_2$-N의 평균 존재 형태별 구성 비율은 각각 78.9, 7.0, 12.4 및 0.8%로 대부분 유기질소 형태이었다. 부영양화도 지수는 남호와 북호에서 2000년에 각각 67과 63에서 2008년에는 63과 59로 감소하였다. 화진포 남호와 북호에서 2007년과 2008년 조사기간 동안 출현한 식물플랑크톤은 총 56속 69종이었다. 식물 플랑크톤의 현존량은 남호가 북호가 각각 18~21,961 및 $153{\sim}10,070\;cells\;mL^{-1}$의 범위로 남호에서 더 많았으며, 남 북호 모두 2007년 7윌에 최소를 보였다. 우점종은 남호의 경우 2007년 5월에 Asterococcus superbus, 9월에 Lyngbya sp., 11월에 Trachelomonas spp.이었으며, 2008년 7월에는 Anabaena spiroides로 시기에 따라 크게 다른 양상을 보였다. 남호와 북호의 종 다양성 지수는 0.87~1.98 (평균 1.41) 및 0.42~1.47 (평균1.07)로 남 북호 모두 2008년 5월에 높았다. 화진포호에서 출현한 동물플랑크톤은 총 31속 35종이었다. 남호의 우점종은 2007년 5, 7월과 2008년 5, 11월에는 요각류의 유생이었으나, 2007년 9월에는 미동정원생동물, 2008년 8월에는 Brachionus plicatilis이었다. 북호의 우점종은 2007년 7월과 11월에는 지각류인 Asplanchna sp.이었으나 그 이외의 시기에는 요각류의 유생이었다. 동물플랑크톤의 밀도는 남호에서 $80{\times}10^3{\sim}3,902{\times}10^3ind.\;L^{-1}$, 북호에서 $88{\times}10^3{\sim}2,106{\times}10^3\;ind.\;L^{-1}$로 남호에서 더 높았다. 종 다양성지수는 남호와 북호가 각각 0.53~0.147 (평균 0.83) 및 0.66~1.46 (평균 1.09)의 범위로 남 북호 모두 2008년 7월에 높았다.

대청호의 시공간적 수질 변화 특성 및 호수내 유입지천의 영향 (Spatio-temporal Fluctuations with Influences of Inflowing Tributary Streams on Water Quality in Daecheong Reservoir)

  • 김경현;이재훈;안광국
    • 생태와환경
    • /
    • 제45권2호
    • /
    • pp.158-173
    • /
    • 2012
  • 본 연구는 대청호 본류유역 7개 지점과 대청호 유입지류 8개 지점을 선정하여 2001년부터 2010년까지 측정된 환경부 수질자료를 분석해 시 공간적 변이를 파악하고, 더불어 대청호 유입 지류에 의한 대청호 수질의 영향을 분석하였다. 본류 수역의 연평균 수질 자료 분석결과에 따르면, 질소(N) 및 인(P)의 농도는 호수대 내에서 상류역에서 댐(M7)으로 갈수록 거리에 따라 1차 함수적으로 감소하는 경향을 보였다. 호수내 유수대(M1~M3), 전이대(M4~M6) 및 정수대(M7)의 TN과 TP는 외국 인공호들과 마찬가지로 뚜렷한 Zonation 패턴을 보였다. 반면, 호수내 유기물 지표로서 엽록소(CHL)와 BOD는 TN과 TP의 구간별 연속적 감소 패턴과는 달리 전이대에서 최고치를 보였다. 유수대에서는 몬순 집중강우기인 8월에 TP가 377 ${\mu}gL^{-1}$로서 최대치를 보였으나, 정수대에서는 7월에 165 ${\mu}gL^{-1}$로서 최대치를 보였다. 한편, 유수대의 TN은 3월 최대치(8.52 $mg\;L^{-1}$)를 보였으며, 정수대의 TN은 본류에 비해 상대적으로 낮은 수치를 보였고, 최대치는 8월 (3.76 $mg\;L^{-1}$)에 관측되었다. 집중강우에 의한 이온희석현상은 9~10월에 극명하게 나타났다. 호수내 제한요인의 평가지표로서 이용되는 TN : TP 비는 88 이상으로서 이미 대청호는 질소가 과잉공급 상태인 것으로 사료되었다. 몬순강우에 따라 호수의 수질은 악화되는 경향을 보였으며, TP와 SS가 강우에 가장 민감하게 반응하였고, CHL은 정수대의 변이 폭이 높게 나타났다. 호수내로 유입되는 지천의 영향평가에 따르면, 도심형 하천이자 농공단지와 하수처리장의 영향을 받고 있는 T1, T2 및 호수내에 가장 큰 영향을 줄 것으로 사료되는 옥천천(T5)의 오염도가 가장 높게 나타났다. 호수의 경험적 모델 분석에 다르면, 호수내에서 CHL의 변이는 유수대($R_z$: $R_2$=0.044, p=0.264)와 전이대 ($T_z$: $R_2$=0.126, p=0.054)에서 TN에 의해 통계학적 유의성을 보이지 않았으나, 정수대($L_z$)에서 질소는 조류 생장에 억제효과($R_2$=0.458, p=0.032)를 가질 수 있는 것으로 나타났다. 한편, 유입 지천($I_w$)의 TN은 호수내($I_r$)의 CHL의 변이에 통계학적으로 유의성이 없는 것으로 나타났고($R_2$=0.258, p=0.110), 유입 지천($I_w$)의 TP는 호수내($I_r$)의 CHL의 변이에 통계학적으로 유의성이 있는 것으로 나타났다 ($R_2$=0.567, p=0.005). 즉, 지천의 TP 유입은 대청호의 조류 생장에 직접적으로 영향을 주는 것을 의미하였다. 한편, 대청호의 TN : TP 비는 지천의 TN보다는 TP에 의한 영향을 받는 것으로 나타나 결국 TN : TP 비는 직접적으로 인(P)의 농도에 의해 조절되는 것으로 나타났다. 따라서 호수내의 여름철 TP와 SS 유입을 최소화 시키고, 높은 인이 유입되는 도심형 하천(옥천천)의 수질 개선이 대청호의 수질 개선에 큰 도움을 줄 것으로 사료되었다.

표식유전자를 이용한 담배와 감자의 원형질체 융합 (Protoplast Fusion of Nicotiana glauca and Solanum tuberosum Using Selectable Marker Genes)

  • 박태은;정해준
    • 자연과학논문집
    • /
    • 제4권
    • /
    • pp.103-142
    • /
    • 1991
  • 표식 유전자를 이용하여 체세포 잡종체를 선발하기 위한 연구의 일환으로 감자조직에는 T-DNA를 도입하여 식물호르몬 무첨가 배지에서도 생장가능한 형질전환체을 획득하고, 담배조직에는 NPT H gene을 도입하여 kanamycin에 대해서 저항성을 나타내는 형질전환체를 획득하여 각각의 특성구명과 원형질체를 유리하여 도입된 유전자 marker를 이용해서 융합을 시도한 바 그 결과는 다음과 같다. 1. 감자 괴경에서 Agrobacterium tumefaciens Ach5와 A. rhizogenes ATCC15834를 접종하여 crown gall tumor 및 hairy root를 유기하였으며 이러한 tumor조직은 식물 호르몬 무첨가 배지에서 생장이 가능하였다. 2. 감자에서 유기된 hairy root로부터 callus 형성은 2.4-D 2mg/1 첨가된 MS 배지에서 가장 양호하였으며 casein hydrolysate 1g/1가 첨가하면 유연 한 callus의 증식이 더욱 왕성하였다. 3. Activated charcoal이 0.5~2.0g/1 첨가된 배지에서는 crown gall tumor callus의 절단면이 갈변되는 것을 방지 할 수 있어 생존률을 높일 수 있었으나 hairy root에서는 갈변되어 고사되었다. 4. 2, 4-D 2mg/1와 casein hydrolysate 1g/1를 첨가한 배지에 hairy root callus를 현탁배의한 결과 양호한 많은 callus 덩어리들을 단시간에 얻을 수 있었다. 5. $Tri^-$parental mating으로 NPTII gene이 coding되어있는 binary vector인 pGA643을 wild type 및 disarmid된 Agrobacterium 내에 도입하여 Agrobacterium tumefaciens Ach5/pGA643, A.tumefaciens $A_4T$/pGA643, A. tumefaciens LBA4404/pGA643를 획득하였다. 이 세 개의 conjugant를 사용하여 0.7% agarose gel 상에서 pGA643을 확인하였다. 6. pGA643이 도입왼 Agrobacterium tumefaciens LBA4404와 담배 조직과 동시배양하여 kanamycin $100\mug$/ml 첨가된 배지에 생존하는 callus를 선발하였으며 동일배지에서 callus의 증식이 가능하였다. 7.형질전환된 담배 callus로부터 식물체 형성은 BA 2mg/1를 첨가한 배지에서 가능하였다. 8. 재분화된 담배의 엽조직은 kanamycin.이 $1000\mug$/ml 첨가된 MS 배지에서도 왕성히 callus가 유기되어, 이는 재분화체에서도 NPTII gene이 그대로 유지되고 있음을 확인할 수 있었다. 9. 담배의 정상 shoot와 형질전환된 shoot를 kanamycin이 $100\mug$/ml이 함유된 MS배지에 기내삽목한 결과, 정상 shoot는 발근이 되지 않고 황화 되었으나 형질전환된 shoot는 발근이되었으며 정상적으로 생장을 하였다. 10. 감자의 T-DNA가 도입된 현탁배양 callus는 cellulase 2%, macerozyme 2%, dricelase 1%에서 양호하게 유리되었다. 11. Osmoticum으로서 mannitol 농도 0.8M에서 담배와 감자의 두 조직 모두 원형질체유리가 가장 효과적이었다. 생존력은 T-DNA가 도입된 감자의 hairy root를 callus로 탈분화 시킨 후 현탁배양한 callus가 mannitol 0.5M에서 97%를 나타냈고, 그리고 NPTII gene이 도입된 담배의 엽조직은 mannitol 0.7M에서 94%로 최고를 타나냈다. 12. 원형질체 융합은 PEG solution 처리 15분 후부터 관찰되기 시작하여 20분에 완전히 융합되었고, 융합된 원형질체는 선발 marker인 호르몬 무첨가 및 kanamycin 첨가배지에서 배양 5일 후에 세포벽이 재생되었으며 4주일 후부터 colony들이 관찰되었다.

  • PDF

Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석 (Comparison of Results According to Reaction Conditions of Thyroglobulin Test)

  • 정승희;이영지;문형호;유소연;김년옥
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.39-43
    • /
    • 2017
  • Thyroglobulin (Tg)은 갑상선에서 특이적으로 생성되는 요오드단백질로써 분화갑상선 암(Differentiate Thyroid Carcinoma, DTC) 의 생물학적 표지자이다. 본 검사실의 Tg 검사법은 반응시간이 길어 진료과와 환자들의 결과보고 요청사항을 만족시키지 못하고 있는 상황이다. 이를 만족시키기 위해 Tg 검사의 반응시간을 단축하고자 현재 사용중인 B사 Kit와 타 병원에서 사용중인 C사 Kit의 반응시간을 단축시켜 실험을 진행하였다. 본원에 의뢰된 Tg 약 65명의 환자 검체를 대상으로 B사 Kit의 반응시간을 $37^{\circ}C$ shaking 2hr/2hr, 실온 shaking 3hr/2hr, $37^{\circ}C$ shaking 1hr/1hr으로, C사 Kit의 원법인 실온 shaking 3hr법과 반응시간을 단축한 실온 shaking 2hr, $37^{\circ}C$ shaking 2hr 방법으로 단축하여 기존에 시행하던 overnight법과 상관성검사를 실시하여 비교하였다. 그 결과 여섯가지 방법 모두 1.0 ng/mL 이상의 값에서는 높은 상관관계를 보였으나 1.0 ng/mL 이하의 값에서는 다소 흔들리는 경향이 있었다. 하지만 그 중 상대적으로 안정적이었던 B사 Kit $37^{\circ}C$ shaking 1hr/1hr 법과 C사 Kit 실온 shaking 2hr 법에 대해 다른 조건들을 재설정하여 적합한 방법을 찾는다면 진료과와 환자들의 요구 사항 충족은 물론, EIA법과의 경쟁력 면에서도 유용할 것이다.

  • PDF

Orchardgrass 및 White Clover의 단파 및 혼파 재배에서 미량요소(Fe, Mn, Cu, Zn, Mo, B)의 조합시비가 목초의 여러 특성에 미치는 영향 I. 목초의 생육, 하고 및 개화 등의 특성 변화 (Effects of Combined Micronutrient(Fe, Mn, Cu, Zn, Mo and B) Application on Forage Traits in Pure and Mixed Swards of Orchardgrass and White Clover I. Changes in the growth, summer depression, and flowering of forage plants)

  • 정연규
    • 한국초지조사료학회지
    • /
    • 제23권4호
    • /
    • pp.229-236
    • /
    • 2003
  • orchardgrass 및 white clover의 단파 및 혼파 재배조건에서 미량요소 Fe, Mn, Cu, Zn, Mo 및 B의 조합시비별 목초의 생육, 개화, 수량, 양분 함량 및 초종간 경합지수 등에 미치는 영향 등을 구명하였다. 다량요소 양분을 동일량 시비한 조건에서 7 수준의 미량요소 조합시비는 T$_1$; 대조구, T$_2$; Fe, T$_3$; Fe+Mn, T$_4$; Fe+Mn+Cu, T$_{5}$; Fe+Mn+Cu+Zn, T$_{6}$;Fe+Mn+Cu+Zn+Mo 및 T$_{7}$; Fe+Mn+Cu+Zn+Mo+B로 하였다. 본 I집에서는 각 조합시비별 목초의 생육, 개화 및 수분생리/하고현상 특성 등에 미치는 영향을 검토하였다. 1, orchardgrass는 T$_3$와 T$_{6}$ 에서 심한 Fe-결핍 황화현상을 보였고, 이는 T$_4$와 T$_{5}$ 에서는 크게 경감되었다. 반면에 T$_1$, T$_2$및 T$_{7}$ 조합시비에서는 황화현상이 없이 정상적인 생육을 보였고, 특히 T$_{7}$완전 조합시비에서는 단파 및 혼파재배 공히 다른 조합시비에 비해서 가장 양호한 생육을 보였다. white clover는 조합시비별 황화현상은 보이지 않았으나 단파재배에서 T$_1$, T$_2$및 T$_{7}$에서는 다른 조합시비에 비해서 더 진한 녹색과 더 양호한 생육을 보였다. 2. 여름 고온기에 orchardgrass는 하고현강을 보였으나 T$_1$과 T$_{7}$에서는 다른 처리구보다 상대적으로 크게 경감 되였다. 황화현상을 보인 조합시비에서는 약한 줄기와 고온으로 인하여 일부 도복현상을 보였다. white clover는 하고현상을 보이지 않았고 처리별 수부요구도의 차이는 분명하지 않았다. 3. 단파재배에서 white clover의 개화 및 화아 수는 T$_{7}$ 및 T$_2$에서 가장 많았고 T$_{7}$에서는 다른 조합시비에 비해서 더 긴 개화기간과 더빠른 만개를 보였다. 이에 비해서 T$_{5}$ 및 T$_{6}$에서는 대조구인 T$_1$보다 적었고 처리 중 가장 적은 개화수를 보였다. T$_{7}$에서 만이 단파 및 혼파재배 공히 개화 수가 화하 수보다 많은 개화 수/화아 수의 비율이 >1 이였다(혼파의 T$_{6}$ 예외). 4. Fe-결핍 황화현상은 항시 부적합한 Fe/Mn과 Fe/Mo 비율에 기인되지 않고, 양이온간(Fe, Mn, Cu, Zn), 음이온간(Mo, B), 그리고 이들의 총 농도의 부조화에도 기인된다는 것을 인지할 수 있었다. 그리고 Fe${\times}$Mn${\times}$Mo${\times}$B 간 다량 교호작용이 있으며 이 때 B의 조정자 역할이 큰 것으로 보였다.

사용후핵연료 심지층 처분장의 완충재 소재인 WRK 벤토나이트의 pH 차이에 따른 우라늄 흡착 특성과 기작 (Uranium Adsorption Properties and Mechanisms of the WRK Bentonite at Different pH Condition as a Buffer Material in the Deep Geological Repository for the Spent Nuclear Fuel)

  • 오유나;신대현;김단우;전소영;김선옥; 이민희
    • 자원환경지질
    • /
    • 제56권5호
    • /
    • pp.603-618
    • /
    • 2023
  • 사용후핵연료(Spent nuclear fuel; SNF) 심지층 처분장의 완충재 소재로서 WRK (waste repository Korea) 벤토나이트가 적합한 지를 평가하기 위하여, 대표적인 방사성 핵종인 U (uranium)에 대한 WRK 벤토나이트의 흡/탈착 특성과 흡착 기작을 규명하는 다양한 분석, 흡/탈착 실내 실험, 동역학 흡착 모델링을 다양한 pH 조건에서 수행하였다. 다양한 특성 분석 결과, 주성분은 Ca-몬모릴로나이트이며, U 흡착 능력이 뛰어난 광물학적·구조적 특징들을 가지고 있었다. WRK 벤토나이트의 U 흡착 효율 및 탈착율을 규명하기 위한 흡/탈착 실험 결과, pH 5, 6, 10, 11 조건에서 WRK 벤토나이트와 U 오염수(1 mg/L)가 낮은 비율(2 g/L)로 혼합되었음에도 불구하고 높은 U 흡착 효율(>74%)과 낮은 U 탈착율(<14%)을 보였으며, 이는 WRK 벤토나이트가 SNF 처분장에서 U 거동을 제한하는 완충재 소재로서 적절하게 사용될 수 있음을 의미한다. pH 3과 7 조건에서는 상대적으로 낮은 U 흡착 효율(<45%)이 나타났으며, 이는 U가 용액의 pH 조건에 따라 다양한 형태로 존재하며, 존재 형태에 따라 상이한 U 흡착 기작을 가지기 때문으로 판단된다. 본 연구 실험 결과와 선행연구를 바탕으로 WRK 벤토나이트의 주요 화학적 U 흡착 기작을 pH 범위에 따라 용액 내 U의 존재 형태에 근거하여 설명하였다. pH 3 이하에서 주로 UO22+ 형태로 존재하는 U는 벤토나이트 표면의 Si-O 또는 Al-O(OH)와의 정전기적 인력(예: 이온 결합)에 의해 흡착되기 때문에 pH가 감소할수록 음전하 표면이 약해지는 WRK 벤토나이트 특성에 의해 비교적 낮은 U 흡착 효율이 나타났다. pH 7 이상의 알칼리성 조건에서 U는 음이온 U-수산화 복합체(UO2(OH)3-, UO2(OH)42-, (UO2)3(OH)7- 등)로 존재하며 비교적 높은 흡착 효율이 나타내는데, 이들은 벤토나이트에 포함된 Si-O 또는 Al-O(OH)의 산소원자를 공유하거나 리간드 교환에 의해 새로운 U-복합체가 형성되어 흡착되거나 수산화물 형태의 공침(co-precipitation)에 의해 벤토나이트에 고정되기 때문이다. pH 7의 중성 조건에서는 pH 5와 6보다 오히려 낮은 U 흡착 효율(42%)이 나타났는데, 이러한 결과는 용액 내 존재하는 탄산염(carbonate)에 의해 U가 U-수산화 복합체보다 용해도가 높은 U-탄산염 복합체로 존재하는 경우 가능하다. 연구 결과 pH를 약산성 또는 염기성 조건으로 유지하거나 용액 내 존재하는 탄산염을 제한함으로써 WRK 벤토나이트의 U 흡착 효율을 높일 수 있는 것으로 나타났다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF