• 제목/요약/키워드: concentration measure

검색결과 1,482건 처리시간 0.027초

점탄성유체의 점성에 관한 실험적 연구 (An experimental study on the viscosity of visco-elastic fluids)

  • 김춘식;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.21-41
    • /
    • 1982
  • Viscosity, especially characteristic among various properties of visco-elastic fluids such as high polymer solutions, is affected mainly by temperature and concentration. Hence, it is important for fluid engineering to express, by some equations, how the fluid characteristics vary with the change of temperature and concentration and to analyze them to obtain consistent viscous characteristics. High polymer solutions, synthetic products of modern chemical industry, suggest many interesting investigations because they are typical visco-elastic materials. Experimentation was made to derive some useful fluid characteristic equations of SEPARAN-NP10 (polyacylamide) expressed by n (flow behavior index) and K' (consistency index) when it is given temperature and concentration variation. To measure viscosity, capillary viscometer was adopted and the range of experimentation is 0-2,000 P.P.M. in concentration and 15-55 .deg.C in temperature. The experimental results are summarized as follows: The flow behavior index n 1) has nearly constant results irrespective of temperature variation at same conentration and the results are shown in (Table. 4-4-3) 2) has following equation, regardless of temperature, for the variation of concentration. n=-1.0765*10$^{-4}$ P+0.9915 (P:P.P.M.) The consistency index K' 1) has different results for the variation of temperature at same concentration and the results are given in (Table.4-7-2) 2) has following equation for the variation of concentration at same temperature. log 10$^{4}$K' =6.4785*10$^{-4}$ P-1.0529 (P:P.P.M)

  • PDF

An investigation on the in si.tu measurement of the oil-concentration

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.80-88
    • /
    • 2000
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method is to extract the working mixture and then to measure the oil weight. In this study, oil concentration is measured in si.tu way without any extraction of the working fluid. Based on the measurement, a working equation is presented as follows, C=a +b x t +c x $t^2$ +(d + e x t +f x $t^2$) x SG. C is oil concentration, t is temperature($^{\circ}C). SG Is specific gravity of mixture and a~f is coefficients The oil concentration ranges over 0~l2 wt% and the temperature ranges over 20~50$^{\circ}C. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/P0E oil liquid mixtures.

  • PDF

데이터 탐색 기법 활용 전도현상 예측모형 (Data Driven Approach to Forecast Water Turnover)

  • 권세혁
    • 산업경영시스템학회지
    • /
    • 제41권3호
    • /
    • pp.90-96
    • /
    • 2018
  • This paper proposed data driven techniques to forecast the time point of water management of the water reservoir without measuring manganese concentration with the empirical data as Juam Dam of years of 2015 and 2016. When the manganese concentration near the surface of water goes over the criteria of 0.3mg/l, the water management should be taken. But, it is economically inefficient to measure manganese concentration frequently and regularly. The water turnover by the difference of water temperature make manganese on the floor of water reservoir rise up to surface and increase the manganese concentration near the surface. Manganese concentration and water temperature from the surface to depth of 20m by 5m have been time plotted and exploratory analyzed to show that the water turnover could be used instead of measuring manganese concentration to know the time point of water management. Two models for forecasting the time point of water turnover were proposed and compared as follow: The regression model of CR20, the consistency ratio of water temperature, between the surface and the depth of 20m on the lagged variables of CR20 and the first lag variable of max temperature. And, the Box-Jenkins model of CR20 as ARIMA (2, 1, 2).

Comparative Analysis of Salivary Cortisol in Young Adult Patients with Temporomandibular Disorders

  • Chan-Young Cheon;Hyun-Jeong Park;Ji-Won Ryu;Jong-Mo Ahn
    • Journal of Oral Medicine and Pain
    • /
    • 제47권4호
    • /
    • pp.183-188
    • /
    • 2022
  • Purpose: The goal of this study was to investigate the causative factors related to the stress of temporomandibular disorders (TMDs) by evaluating salivary cortisol concentration in young adult TMD patients and control groups. Methods: Saliva was obtained from 32 young adult TMDs patients and 34 control patients without a history of TMDs who visited Chosun University Dental Hospital between June 1 and August 31, 2021. Enzyme-linked immunosorbent assay was conducted to measure the salivary cortisol concentration. Results: The salivary cortisol concentration in the TMD patient group and the control group differed significant significantly (p<0.05). The salivary cortisol concentration according to the duration of the clinical symptom of TMD differed significantly difference between the two groups in the male. The salivary cortisol concentration according to perceived stress level differed significantly in the mild and moderate groups (p<0.05). There was no significant difference in salivary cortisol concentration between the two groups related to bruxism or clenching (p>0.05). Conclusions: The salivary cortisol concentration in the TMD patient group and the control group showed statistical relevance, indicating that stress was a causative factor.

공간의 특성을 고려한 조도 측정방법에 관한 연구 (The Measurement Method of the Illuminance Considering Space Characteristics)

  • 주근탁;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.3-7
    • /
    • 2005
  • A lighting method of our county is ordinary center concentration form. Therefore, it is usally used the Five Point Method, Multiplicity Method of KS, and Four Point Method of IES to measure a space illuminance. We can use the Five Point Method of KS when we measure a uniformity ratio or activities that happen in space is more sensitive than whole illumination. In addition, we can use the Multiplicity Method of KS and Four Point Method of IES when we measure whole illuminance like mean illuminance. Such method of measurements should be used exactly according to the kinds of space and activities.

  • PDF

저농도 알코올 측정을 위한 다공질 실리콘 센서에 관한 연구 (Study on Porous Silicon Sensors to Measure Low Alcohol Concentration)

  • 김성진
    • 전기화학회지
    • /
    • 제2권3호
    • /
    • pp.130-133
    • /
    • 1999
  • 본 연구에서는 음주 측정에 적용할 수 있는 다공질 실리콘층으로 된 저농도의 캐퍼시턴스형 알코올 가스 측정용 센서를 제작하고, 상온에서 그 특성을 측정하였다. 기존의 $SnO_2$등의 금속 산화물 반도체를 이용한 센서는 저농도의 알코올을 정확하게 검지하기에 어려울 뿐만 아니라 감도를 높이기 위해 $200\~400^{\circ}C$로 가열이 필요하였다. 이에 비해 다공질 실리콘층을 이용한 센서는 넓은 표면적을 갖고 있어 상온에서도 감도가 양호할 뿐만 아니라 집적화 센서로 제작이 용이한 점을 갖고 있다. 실험은 증류수에 희석한 알코올 수용액을 체온과 같은 $36^{\circ}C$를 비롯하여 25와 $45^{\circ}C$로 유지한 상태에서 0에서 $0.5\%$의 농도범위에 대해서 $0.05\%$의 간격으로 120 Hz와 1 kHz의 두 주파수에서 측정하였다. 그 결과, 양호한 선형성과 함께 120 Hz의 주파수에서 측정하였을 때, $0.1\%$의 알코올 농도의 증분마다 $25,\;36,\;45^{\circ}C$의 알코올 수용액의 온도에 대해 각각 1.1, 2.6 및 $4.6\%$로 캐퍼시턴스의 증가율을 보였다.

뇌의 양성자 핵자기공명 분광학을 위한 정량화 방법 개발 (The Development of Quantification Technique for Brain In vivo Proton NMR Spectroscopy)

  • 강해진
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.31-39
    • /
    • 2001
  • 핵자기공명분광학(NMR Spectroscopy)을 이용해서 우리는 생물체의 조직안에 있는 각종 대사물질들을 측정할 수 있게 되었으며, 이것은 또 지금까지 알려진 여러 방법 중에서 생물체내의 신진대사 물질이나 생화학적인 변화를 비침습적(noninvasive)으로 알아낼 수 있는 유일한 방법에 속한다. 양성자 핵자기공명분광학은 최근들어 사람이나 흑은 동물뇌의 생화학적인 특성을 연구하는데 많이 사용되어오고 있다. 핵자기공명영상은 주로 물분자에 있는 양성자의 밀도와 그들의 이완현상(relaxation phenomena)을 측정하여 영상화하지만 핵자기공명분광학은 생체조직내의 신진대사에 관한 생화학적인 정보를 제공한다. 많은 경우에 있어서 핵자기공명분광학은 CT나 MRI 영상에서는 발견할 수 없는 정보를 제공함으로써 특정질병의 진단에 사용될 수 있으며, 따라서 환자들의 질병상태를 효과적으로 진단하는데 쓰여질 수 있다. 따라서 본 연구에서는 사람의 뇌에서 수소 핵자기공명분광학을 이용하여 대사물질들의 농도를 정량화하는 방법을 시도하였다. 이를 위해 펀텀을 이용하여 대사물질들 각각의 스팩트럼을 구했고, 성인 남녀 16명을 대상으로 insula gray matter 부위의 대사물질들의 농도를 측정하였다. 그리고 이 값들은 다른 연구자들에 의해 밝혀진 값들과 매우 근사한 값을 제공하였다.

  • PDF

센서 네트워크 기반 지능 로봇의 냄새 인식 및 추적 (Odor Cognition and Source Tracking of an Intelligent Robot based upon Wireless Sensor Network)

  • 이재연;강근택;이원창
    • 한국지능시스템학회논문지
    • /
    • 제21권1호
    • /
    • pp.49-54
    • /
    • 2011
  • 본 논문에서는 실내 환경에서 발생 할 수 있는 각종 냄새를 구분하고 농도를 검출하여 냄새 발생지로의 탐색과 이에 관련된 정보를 전송하는 지능 로봇을 구현 하였다. 온도변화에 따라 구동 되는 반도체식 가스센서를 이용하여 에탄올, 암모니아 및 이들의 혼합가스를 신경망 알고리즘을 통해 구분하고, 퍼지 추론방식으로 농도 측정이 가능한 후각 기능을 구현 하여 탑재함과 동시에 비전 시스템을 이용하여 장애물 회피 이동이 가능하게 하였다. 또한 로봇은 센서 네트워크 내에서 동작하며 유해 가스 및 냄새 관련 정보와 이에 따른 경고 메시지를 멀티홉 방식으로 네트워크 내 다른 노드로 전송한다. 비전 시스템과 후각 센서를 이용한 알고리즘으로 냄새의 종류 구분 및 농도 측정, 발생지 탐색이 가능 하였고 센서 네트워크 내 동작으로 이러한 정보전송이 가능한 로봇을 제시 하였다. 실제 실험을 통하여 냄새 인식 및 농도검출, 그리고 냄새 발생지로의 탐색 알고리즘 및 정보전송 성능의 효용성을 입증 하였다.

광 계수 방식의 라만 라이다 시스템을 이용한 원격 수소 가스 농도 계측 방법에 대한 연구 (Study of a Method for Measuring Hydrogen Gas Concentration Using a Photon-counting Raman Lidar System)

  • 최인영;백성훈;차정호;김진호
    • 한국광학회지
    • /
    • 제30권3호
    • /
    • pp.114-119
    • /
    • 2019
  • 본 논문은 원격으로 수소 가스의 계측이 가능한 광 계수 방식의 소형 라만 라이다 시스템 개발에 관한 것이다. 수소 가스에 의한 라만 신호는 매우 미약한 신호로서, 신호 대 잡음비가 매우 낮다. 광 계수기는 광 판별기를 갖고 있어, 레이저에 의하여 발생한 배경 신호의 전기적 잡음을 제거할 수 있는 장점을 갖고 있다. 본 연구에서는 출력이 낮은 레이저와 광 계수기를 이용하여 소형의 라만 라이다 시스템을 개발하였다. 개발된 광 계수 방식의 라만 라이다 시스템의 원격 수소 가스 검출 능력을 증명하기 위하여 수소 가스 농도를 조절할 수 있는 가스 챔버를 이용하여 수소 가스 농도 측정 실험을 수행하였다. 그 결과 10 m 거리에서 최소 0.65 vol.%의 수소 가스 농도 검출이 가능하였다.

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성 (Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC))

  • 정창훈;조용성;이종태
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.