• 제목/요약/키워드: concentration distributions

검색결과 684건 처리시간 0.023초

적외선 열화상 응력측정법에 의한 동적 응력집중계수 예측 (Estimation of Dynamic Stress Concentration Factor by Infrared Thermography Stress Analysis)

  • 최만용;강기수;박정학;안병욱;김경석
    • 한국정밀공학회지
    • /
    • 제25권5호
    • /
    • pp.77-81
    • /
    • 2008
  • Structural components subjected to high frequency vibrations, such as those used in vibrating parts of gas turbine engines, are usually required to avoid resonance frequencies. Generally, the operating frequency is designed at more than resonance frequencies. When a vibrating structure starts or stops, the structure has to pass through a resonance frequency, which results in large stress concentration. This paper presents the transient thermoelastic stress analysis of vibrating cantilever beam using infrared thermography and finite element method (FEM). In FEM, stress concentration factor at the 2nd resonance vibration mode is calculated by the mode superposition method of ANSYS. In experiment, stress distributions are investigated with infrared thermography and dynamic stress concentration factor is estimated. Experimental result is agreed with FEM result within 10.6%. The advantage of this technique is a better immunity to contact problem and geometric limitation in stress analysis of small or micro structures.

Estimation of Phosphorus Concentration in Silicon Thin Film on Glass Using ToF-SIMS

  • Hossion, M. Abul;Murukesan, Karthick;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • 제12권2호
    • /
    • pp.47-52
    • /
    • 2021
  • Evaluating the impurity concentrations in semiconductor thin films using time of flight secondary ion mass spectrometry (ToF-SIMS) is an effective technique. The mass interference between isotopes and matrix element in data interpretation makes the process complex. In this study, we have investigated the doping concentration of phosphorus in, phosphorus doped silicon thin film on glass using ToF-SIMS in the dynamic mode of operation. To overcome the mass interference between phosphorus and silicon isotopes, the quantitative analysis of counts to concentration conversion was done following two routes, standard relative sensitivity factor (RSF) and SIMetric software estimation. Phosphorus doped silicon thin film of 180 nm was grown on glass substrate using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using ToF-SIMS, the phosphorus-31 isotopes were detected in the range of 101~104 counts. The silicon isotopes matrix element was measured from p-type silicon wafer from a separate measurement to avoid mass interference. For the both procedures, the phosphorus concentration versus depth profiles were plotted which agree with a percent difference of about 3% at 100 nm depth. The concentration of phosphorus in silicon was determined in the range of 1019~1021 atoms/cm3. The technique will be useful for estimating distributions of various dopants in the silicon thin film grown on glass using ToF-SIMS overcoming the mass interference between isotopes.

粒子狀 物質中 金屬成分의 密度分布 (Density Distributions of Metallic Compounds in Particulate Matters)

  • 허문영;김형춘;손동헌
    • 한국대기환경학회지
    • /
    • 제2권2호
    • /
    • pp.9-18
    • /
    • 1986
  • For identification and apportionment of sources emitting particulate matters in environment, the multi-elemental characterization of size-density fractionated particulate matters was carried out. Eight types of samples were tested; soil, flyash released from burning of bunker-Coil, diesel oil, coal, and soft coal, urban road-way dust, urban dust fall, and airborne particulate matter. The fractions of particulate matters obtained by heavy liquid separation methos with a series of dichloromethane-bromoform were then analyzed using atomic absorption spectrophotometry for Ni, Cr, Cu, An, Fe, Al, and Mg. Each sample showed a different concentration profile as a function of density, and a number of useful conclusions concerning characterization of elemental distribution were obtained. From the density distributions of elements in soil, the maximum value was found for all elements in the density range of 2.2 $\sim 2.9g.cm^{-3}$, including the density of $SiO_2$. However, the distribution of metallic compounds with the density lower than $2.2g.cm^{-3}$ was prevalent in urban roadway dust, urban dust fall, and airborne particulate matter. And the density distribution curves of these urban dusts also have the higher distribution at the density of 2.2 - 2.9g.cm^{-3}$, including the density of wind-blown silica. This tendency generally was prevalent in the natural source elements, such as Al, Fe, Mn, and Mg. The maximum values were found in the density ranges of 1.3 $\sim 2.2g.cm^{-3}$ from the density distribution of elements in oil fired flyash. These distributions of anthropogenic source elements, such as Zn, Ni, Cu, and Cr were higher predominately than those of natural source elements. And the higher distribution was found in the density range of $2.2 \sim 2.9g.cm^{-3}$ from the density distribution of elements in coal and soft-coal fired flyash. These distributions showed similar patterns to soil. But anthropogenic source elements somewhat predominated at the density ranges of $1.3 \sim 2.2g.cm{-3} and 2.9g.cm^{-3}$ to soil. Therefore the higher distribution of anthropogenic source elements in the density ranges of $1.3 \sim 2.2g.cm^{-3} and 2.9g.cm^{-3}$ was considered as anthropogenic origin.

  • PDF

태양열 집광기의 초점 지역에 형성된 플럭스 밀도 분포의 특성 (An Experimental Study on the Characteristics of Flux Density Distributions in the Focal Region of a Solar Concentrator)

  • 현성택;강용혁;윤환기;유창균;강명철
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.31-37
    • /
    • 2002
  • This experimental study represents the results of an analysis on the characteristics of flux density distributions in the focal region of solar concentrator. The characteristics of flux density distributions are investigated to optimally design and position a cavity receiver. This deemed very useful to find and correct various errors associated with a dish concentrator. We estimated the flux density distribution on the target placed along with focal lengths from the dish vertex to experimentally determine the focal length. It is observed that the actual focal point exists when the focal length is 2.17 m. We also evaluated the position of flux centroid, and it was found that there were errors within 2 cm from the target center. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius.

어린이용품 노출평가 연구에서의 결정론적 및 확률론적 방법론 사용실태 분석 및 고찰 (Comparison of Deterministic and Probabilistic Approaches through Cases of Exposure Assessment of Child Products)

  • 장보윤;정다인;이헌주
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.223-232
    • /
    • 2017
  • Objectives: In response to increased interest in the safety of children's products, a risk management system is being prepared through exposure assessment of hazardous chemicals. To estimate exposure levels, risk assessors are using deterministic and probabilistic approaches to statistical methodology and a commercialized Monte Carlo simulation based on tools (MCTool) to efficiently support calculation of the probability density functions. This study was conducted to analyze and discuss the usage patterns and problems associated with the results of these two approaches and MCTools used in the case of probabilistic approaches by reviewing research reports related to exposure assessment for children's products. Methods: We collected six research reports on exposure and risk assessment of children's products and summarized the deterministic results and corresponding underlying distributions for exposure dose and concentration results estimated through deterministic and probabilistic approaches. We focused on mechanisms and differences in the MCTools used for decision making with probabilistic distributions to validate the simulation adequacy in detail. Results: The estimation results of exposure dose and concentration from the deterministic approaches were 0.19-3.98 times higher than the results from the probabilistic approach. For the probabilistic approach, the use of lognormal, Student's T, and Weibull distributions had the highest frequency as underlying distributions of the input parameters. However, we could not examine the reasons for the selection of each distribution because of the absence of test-statistics. In addition, there were some cases estimating the discrete probability distribution model as the underlying distribution for continuous variables, such as weight. To find the cause of abnormal simulations, we applied two MCTools used for all reports and described the improper usage routes of MCTools. Conclusions: For transparent and realistic exposure assessment, it is necessary to 1) establish standardized guidelines for the proper use of the two statistical approaches, including notes by MCTool and 2) consider the development of a new software tool with proper configurations and features specialized for risk assessment. Such guidelines and software will make exposure assessment more user-friendly, consistent, and rapid in the future.

다목적 최적화기법을 활용한 상수도 공급계통 잔류염소농도 최적운영 모델 개발 (Development of optimization model for booster chlorination in water supply system using multi-objective optimization method)

  • 김기범;서지원;형진석;김태현;최태호;구자용
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.311-321
    • /
    • 2020
  • In this study, a model to optimize residual chlorine concentrations in a water supply system was developed using a multi-objective genetic algorithm. Moreover, to quantify the effects of optimized residual chlorine concentration management and to consider customer service requirements, this study developed indices to quantify the spatial and temporal distributions of residual chlorine concentration. Based on the results, the most economical operational method to manage booster chlorination was derived, which would supply water that satisfies the service level required by consumers, as well as the cost-effectiveness and operation requirements relevant to the service providers. A simulation model was then created based on an actual water supply system (i.e., the Multi-regional Water Supply W in Korea). Simulated optimizations were successful, evidencing that it is possible to meet the residual chlorine concentration demanded by consumers at a low cost.

광양만내의 현장 부유입자물질 분포와 거동 (Distribution and Behaviors of In-Situ Suspended Particulate Matters of Gwangyang Bay)

  • 이병관;김석윤;조현만
    • 한국해양공학회지
    • /
    • 제24권1호
    • /
    • pp.99-105
    • /
    • 2010
  • The concentration and size analysis of in-situ suspended particulate material were measured using an optical instrument, LISST-100, in the bottom layer at the three inlets of the Seomjin River Estuary, mouth of Gwangyang bay, and Gwangyang bay-side of the Namhae Bridge. In the Seomjin river estuary and mouth of Gwangyang bay-side of the Namhae Bridge, the in-situ mean grain size of the suspended material changed from a uni-modal distribution with a dominant peak at a coarse fraction to a bi-modal distribution with a secondary peak at the finer particles. Seomjin River. The interactions between suspended particulate concentration and beam attenuation coefficient of suspended particulate matters depended on the supply of finer and coarser particles in the mouth of Gwangyang Bay and Seomjin River. So, interactions reflected difference of the concentration, mean size and sorting of suspended particulate matters. The difference of interaction showed dynamic behaviors to the resuspension and deflocculation processes increased river discharge. This showed that it may be possible to use the interactions between the suspended particle concentration and beam attenuation coefficient to monitor the temporal and spatial distributions of in-situ particles.

회전하는 환형용기내의 옆면 가열에 의한 이중확산대류에 관한 수치해석 (Numerical study of double diffusive convection due to lateral heating in a rotating annulus)

  • 강신형;이교승;이진호
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1422-1436
    • /
    • 1997
  • Numerical investigations were conducted to study the convective phenomena of an initially stably stratified salt water solution with lateral heating in a uniformly rotating annulus. The method of investigation is the finite difference analysis of the basic conservation equation for an axisymmetric, unsteady, double-diffusive convection and calculation is made for R $a_{\eta}$=2*10$^{5}$ and Ta=10$^{7}$ ~ 2.5*10$^{8}$ . Formation of layered flow structure, merging process of layers, the corresponding temperature and concentration distributions, Nu variation with time are examined. Numerical results show that in each layer, the temperature profile looks 'S'-shaped and the concentration profile is uniform due to the convective mixing. At the interface between adjacent layers, the temperature changes smoothly but the concentration changes rapidly. As the effect of the rotation increases, the generation of rolls at hot wall, the formation and merging of layers are delayed. The average Nu shows the trend of conduction heat transferees the effect of the rotation increases.n increases.

Methamphetamine 남용자에 있어서 혈청 아연농도에 관한 연구 (A Study on Serum Zinc Concentration in some Methamphetamine Abusers)

  • 문형일;이후락;이수일
    • Journal of Preventive Medicine and Public Health
    • /
    • 제25권2호
    • /
    • pp.172-179
    • /
    • 1992
  • The author investigated the zinc concentrations in sera of 110 methamphetaimine abusers (male 87, female 23) and of 41 healthy official workers(male 29, female 12) using inductively coupled plasma emission spectrometer. The serum zinc concentrations were analysed according to hepatitis C virus antibody(Anti HCV), hepatitis B surface antigen(HBsAg) and alanine aminotransferase(ALT) value in both groups. The analytical results were obtained as follows 1. The mean zinc concentration of MAP abuser group($298.5{\pm]246.9{\mu}g/100ml$) was 2.5 times higher than that of control group($118.8{\pm}25.4{\mu}g/100ml$). 2. The distributions of zinc concentration in both groups were skewed pattern. 3. The zinc concentrations were higher in Anti HCV-positive group and abnormal ALT value group than Anti HCV-negative group and normal ALT value group. But HBs-Ag positive group had lower zinc concentration than HBs-Ag negative group. 4. The number of anti HCV-positive subjects was increased and the zinc concentrations were decreasd in proportion to the abusing duration of MAP.

  • PDF

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF