• Title/Summary/Keyword: concentration control system

Search Result 1,329, Processing Time 0.034 seconds

Design of Gas Concentration Process with Thermally Coupled Distillation Column Using HYSYS Simulation (HYSYS를 이용한 열복합 증류식 가스 농축공정의 설계)

  • 이주영;김영한;황규석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.10
    • /
    • pp.842-846
    • /
    • 2002
  • Design of gas concentration process using a fully thermally coupled distillation is conducted with the commercial design software HYSYS. Detailed procedure of the design is explained, and the performance of the process is compared with that of a conventional system A structural design is exercised for the design convenience. The design outcome indicates that the procedure is simple and efficient. The structural information yielded from equilibrium distillation gives an easy formulation of distillation system which is the initial input required from the setup of the distillation system The performance of the new process indicates that an energy saving of 17.6 % is obtained compared with the conventional process while total number of trays maintains at the same.

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

Auto Alarm System of Replacement Period for Vehicle Cabin Filter & Interception System of High Concentration Dust (차량용 에어컨필터 교환시점 알림 시스템 및 과농도 먼지 차단 시스템)

  • Lee, Kyu-Se;Byeon, Seong-Uk;Kim, Yeong-Min;Park, Sung-Woo;Yum, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.11
    • /
    • pp.1035-1040
    • /
    • 2008
  • Replacement period for vehicle cabin filter of most automobiles is fixed without consideration of conditions of filter and environment. Auto alarm system of replacement period at vehicle cabin filter and interception system of high concentration dust were developed. Control program which is related with the AQS has been developed based on the circuit drive algorithm. This system is expected to be beneficial to passenger's health and to extend the life of the filter which regulates vehicle HVAC system by ventilation mode change at the time of high concentration dust.

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

Container System Actively Maintaining High CO2 Concentration for Improved Sensory Quality of Kimchi

  • Lee, Hye Lim;An, Duck Soon;Jung, Yong Bae;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.79-84
    • /
    • 2016
  • A kimchi container actively controlling $CO_2$ concentration by timely flushing of $CO_2$ gas was structured and tested in its capability and effectiveness because high $CO_2$ concentration enhances the sensory flavor of the product. The inlet and outlet valves of $CO_2$ gas were programmed to open and close allowing synchronous vent/$CO_2$ flush according to the requirements of its dissolution in the contained kimchi. During the chilled storage, the headspace of container could be maintained at desired high $CO_2$ concentration providing the preferred kimchi in sensory quality compared to control of the conventional container. However, there was no significant difference between the high $CO_2$ container and control (container simply closed with air) in kimchi quality attributes of pH, titratable acidity, total viable bacterial count, Lactobacillus sp. count and Leuconostoc sp. count. The flow rate and time interval of $CO_2$ flushing need to be adjusted considering the kimchi amount, headspace volume and ripening time. The designed system has potential to be applied in refrigerator appliances in homes and food service industry.

Automatic mushroom cultivation system using CAN (CAN을 이용한 자동 버섯재배 시스템)

  • Kim Y. S.;Kim Y. D.;Jeon H. S.;Shin S. D.;Oh G. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.172-176
    • /
    • 2004
  • In this paper, We are inclined to design automated mushroom-cultivation system technology grafting communication technology as CAN(Control Area Network). Mushroom cultivation automated system have a goal to construct stable crop cultivation system ,as we construct embedded-system that can make into one to advance current system. Its sensor part is composed of temperature , humidity and CO2 concentration sensor and of chilling, heating and unit humidity-controlling unit, ventilation fan. In particular, having saved analized temperature, humidity, CO2 concentration data in each sensor, CAN which can control realtime communication is used to analyze the next mushroom-cultivation.

  • PDF

Feasibility Study of the Combustible Gab Control System Following a LOCA (냉각재 상실사고시 가연성 가스제거 계통의 타당성 조사)

  • Hyung Won Lee;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • v.16 no.4
    • /
    • pp.217-223
    • /
    • 1984
  • The feasibility of not employing recombiners rather using the postaccident Purge system alone to control hydrogen concentration in the containment following a LOCA, is analyzed in this paper. For this study, the hydrogen concentration in the containment, hydrogen removal through the purge system, and additional off-site dose due to hydrogen purge were calculated. The economic justification of a hydrogen recombiner system (2 recombiners) was also investigated by using the cost benefit concept. As a result, the purge system is sufficient to maintain the hydrogen concentration at a safe level without hydrogen recombiners, and it meets the dose limit requirements set forth in 10 CFR part 100. A hydrogen recombiner system would be justified based on cost-benefit concept for common use in a site with 4 units or more.

  • PDF

Water Mist Fire Suppression for Raised Subfloor Spaces

  • Kim, Woon-Hyung;Kim, James A. Milke
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.617-624
    • /
    • 1997
  • Over 100 experiments have been conducted at the University of Maryland to evaluate the performance of a water mist fire suppression system for protection of an interstitial space below a raised subfloor. Experiments are conducted as part of an ongoing research effort to compare the fire suppression capabilities of various water mist system designs in a raised subfloor space. Water mist system design parameters considered in the investigation include means of actuation, concentration of water mist required for extinguishment of fires, and delivery mechanisms of water mist within close proximity to the fire. Delivery of the required concentration of water mist within close proximity to the fire is a principal factor governing the adequacy of water mist systems. Two sets of experiments have been conducted to document the performance of water mist system designs. One set is involved in documenting the concentration of water mist as a function of position within the space. The second set of experiments is concerned with the ability of water mist system designs to control fires in the space. One result of the research is the assessment of the ability of a water mist system to control fires at particular locations as a function of water mist density at that location.

  • PDF

LM-BP algorithm application for odour classification and concentration prediction using MOS sensor array (MOS 센서어레이를 이용한 냄새 분류 및 농도추정을 위한 LM-BP 알고리즘 응용)

  • 최찬석;변형기;김정도
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.210-210
    • /
    • 2000
  • In this paper, we have investigated the properties of multi-layer perceptron (MLP) for odour patterns classification and concentration estimation simultaneously. When the MLP may be has a fast convergence speed with small error and excellent mapping ability for classification, it can be possible to use for classification and concentration prediction of volatile chemicals simultaneously. However, the conventional MLP, which is back-Propagation of error based on the steepest descent method, was difficult to use for odour classification and concentration estimation simultaneously, because it is slow to converge and may fall into the local minimum. We adapted the Levenberg-Marquardt(LM) algorithm [4,5] having advantages both the steepest descent method and Gauss-Newton method instead of the conventional steepest descent method for the simultaneous classification and concentration estimation of odours. And, We designed the artificial odour sensing system(Electronic Nose) and applied LM-BP algorithm for classification and concentration prediction of VOC gases.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF