• Title/Summary/Keyword: concentrated load

Search Result 535, Processing Time 0.025 seconds

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Numerical Analyses for Evaluating Factors which Influence the Behavioral Characteristics of Side of Rock Socketed Drilled Shafts (암반에 근입된 현장타설말뚝의 주면부 거동에 영향을 미치는 변수분석을 위한 수치해석)

  • Lee, Hyuk-Jin;Kim, Hong-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6C
    • /
    • pp.395-406
    • /
    • 2006
  • Drilled shafts are a common foundation solution for large concentrated loads. Such piles are generally constructed by drilling through softer soils into rock and the section of the shaft which is drilled through rock contributes most of the load bearing capacity. Drilled shafts derive their bearing capacity from both shaft and base resistance components. The length and diameter of the rock socket must be sufficient to carry the loads imposed on the pile safely without excessive settlements. The base resistance component can contribute significantly to the ultimate capacity of the pile. However, the shaft resistance is typically mobilized at considerably smaller pile movements than that of the base. In addition, the base response can be adversely affected by any debris that is left in the bottom of the socket. The reliability of base response therefore depends on the use of a construction and inspection technique which leaves the socket free of debris. This may be difficult and costly to achieve, particularly in deep sockets, which are often drilled under water or drilling slurry. As a consequence of these factors, shaft resistance generally dominates pile performance at working loads. The efforts to improve the prediction of drilled shaft performance are therefore primarily concerned with the complex mechanisms of shaft resistance development. The shaft resistance only is concerned in this study. The nature of the interface between the concrete pile shaft and the surrounding rock is critically important to the performance of the pile, and is heavily influenced by the construction practices. In this study, the influences of asperity characteristics such as the heights and angles, the strength characteristics and elastic constants of surrounding rock masses and the depth and length of rock socket, et. al. on the shaft resistance of drilled shafts are investigated from elasto-plastic analyses( FLAC). Through the parametric studies, among the parameters, the vertical stress on the top layer of socket, the height of asperity and cohesion and poison's ratio of rock masses are major influence factors on the unit peak shaft resistance.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.

A Study on the Changes in Gwi-po from Tang to Jin Dynasty in China - Focusing on the connection type of Jwau-dae(左右隊) - (중국 당대~금대 목조 건축의 귀포 변천에 관한 연구 - 좌우대의 결구 유형을 중심으로 -)

  • Lee, Byung-Chun;Lee, Ho-Yeol
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.3
    • /
    • pp.96-119
    • /
    • 2015
  • This research has studied the changes of Gwi-po(轉角包) by taking the cases of China's medieval wooden buildings as objects. The purpose of the study is to examine the time-periodic transition process of Gwi-po through the cases of 71 wooden buildings which were built from Tang(唐) dynasty(AD 618~690 & 705~907) until Jin(金) dynasty(AD 1115~1234) and also designated as 'Major Historical and Cultural Sites Protected at the National Level'. This research has taken note of various frame types of Jwau-dae(左右隊), which are architectural components of Gwi-po, to study the changes and development process of Gwi-po. The results are as follows. An important factor in the transformations of Gwi-po format is the changes in perception of the craftsmen about Jwau-dae, who took charge in the building process. In the early periods, the principles of Yidou sanshen dougong(一斗三升) in constructing ancons of Gwi-po had been well-maintained, while there appeared many different types of Gwi-po in later periods, due to the usage of Jwau-dae and $Shu{\check{a}}$ $t{\acute{o}}u$(?頭) in each Chulmok of Gwi-po. Transitional types of Gwi-po, which were evolved from the earlier ones, are divided into 3 categories by different forms of Jwau-dae, placed on odd number stages. The first one is 'none-$f{\bar{a}}ng$ $t{\acute{o}}u$(無枋頭) type' of Song(AD 960~1127, 1127~1279) and Liao dynasty(AD 907~1125) buildings, which doesn't have $f{\bar{a}}ng$ $t{\acute{o}}u$(枋頭)s, for the reason that Jwau-dae(左右隊) is in direct contact with Gwihan-dae(耳限大). The second one is '$Shu{\check{a}}$ $t{\acute{o}}u$ $f{\bar{a}}ng$ $t{\acute{o}}u$(?頭枋頭) type' of Song(AD 960~1127, 1127~1279) and Jin dynasty(AD 1115~1234), that has $f{\bar{a}}ng$ $t{\acute{o}}u$(枋頭)s of Jwau-dae(左右隊) identical to $Shu{\check{a}}$ $t{\acute{o}}u$(?頭) in form. The last one is '$Xi{\check{a}}o$ $g{\check{o}}ng$ $t{\acute{o}}u$(小?頭) type' of Jin(AD 1115~1234) and Yuan dynasty(AD 1271~1368), which has $f{\bar{a}}ng$ $t{\acute{o}}u$(枋頭)s of Jwau-dae identical to $Xi{\check{a}}o$ $g{\check{o}}ng$ $t{\acute{o}}u$(小?頭) in form. The earlier forms of Gwi-po, which appeared between Tang dynasty(AD 618~690 & 705~907) and Five Dynasties periods(907~960) went through transitional forms of 'non-$f{\bar{a}}ng$ $t{\acute{o}}u$(無枋頭) type', '$Shu{\check{a}}$ $t{\acute{o}}u$ $f{\bar{a}}ng$ $t{\acute{o}}u$(?頭枋頭) type' and '$Xi{\check{a}}o$ $g{\check{o}}ng$ $t{\acute{o}}u$(小?頭) type' and finally had its form settled between Yuan(元, AD 1271~1368) and Ming(明. AD 1368~1644) dynasty periods. In Liao(遼) dynasty period(AD 907~1125), as the buildings got bigger and the tendency of longer eave-exposure was implemented, there grew a certain need to structurally reinforce Gwi-po, on which load of the whole roof is concentrated. Especially, the transition from Tōuxīn $z{\grave{a}}o$(偸心造) style to Jì xīn $z{\grave{a}}o$(計心造) style in this period had a great influence on standardization of Gwi-po, along with None-${\acute{A}}ng$(無仰) style. Furthermore, Wing-type Gong(翼型?), which developed in Liao dynasty(AD 907~1125), is also thought to have had a great influence on the transition from Tōuxīn $z{\grave{a}}o$(偸心造) style to Jì xīn $z{\grave{a}}o$(計心造) style by changing the forms of Gongs(?), such as Gwi-po. However, unlike None-${\acute{A}}ng$(無仰) style, there occurred a gradual change from '$Shu{\check{a}}$ $t{\acute{o}}u$ $f{\bar{a}}ng$ $t{\acute{o}}u$(?頭枋頭) type' to '$Xi{\check{a}}o$ $g{\check{o}}ng$ $t{\acute{o}}u$(小?頭) type' of Gwi-po in $Xi{\grave{a}}$ ${\acute{a}}ng$ style.