• 제목/요약/키워드: computer-assisted

검색결과 690건 처리시간 0.027초

Effects of Sperm Motility on In Vitro Production of Embryo and Correlation with Mitochondria Amount in Pig

  • Chung, Ki-Hwa;Kim, In-Cheul;Son, Jung-Ho
    • 한국수정란이식학회지
    • /
    • 제25권4호
    • /
    • pp.263-266
    • /
    • 2010
  • Prediction of semen's fertilizing ability used in artificial insemination (AI) is one of very important factors on pig reproductive performance. In vitro fertilization (IVF) has been used for indirect evaluation of sperm's fertilizing ability and it has been showed as highly correlated index. In swine industry, increasing interest in preservation of boar semen raises questions on the sperm motility from semen used in commercial AI centers. Mitochondria in sperm mid-piece generate the energy to support motility and could be an explanation of impaired fertility. Objective of this study was to suggest usable sperm motility to farms in measuring the effect of sperm motility and sperm abnormality on in vitro production of embryo in which sperm's fertilizing ability can be determined indirectly. Semen samples were provided from local AI center and used within 3 days after collection. Semen samples were divided by 4 different motile groups (>70%; 61~70%; 51~60%; <50%) using CASA (computer-assisted sperm analysis) on the days of IVF. Developmental rate to the blastocyst stage from over 61% motile sperm group showed significantly higher rate than below 60% motile sperm group ($16.5{\pm}0.7{\sim}18.4{\pm}0.8%$ vs $6.3{\pm}0.8{\sim}11.5{\pm}0.7%$, p<0.05). In experiment to determine the relationship between sperm motility and viability and abnormality, over 61% motile sperm groups showed significantly higher viability rate compared to below 60% motile sperm groups ($84.8{\pm}4.0{\sim}88.1{\pm}4.0%$ vs $69.1{\pm}4.0{\sim}74.2{\pm}4.0%$, p<0.05). On the other hand, morphological sperm abnormality showed significantly higher in over 70% motile sperm group ($10.2{\pm}2.2$ vs $16.0{\pm}2.2{\sim}21.0{\pm}2.2%$, p<0.05). In experiment to find the correlation between sperm motility of 4 different motile groups and amount of mitochondria, lower motility group also showed lower level of mitochondria (p<0.05). The mitochondria parameter used in this study showed another possibility to differentiate the sperm motility. Taken together, because below 60% motile semen used in AI reduce the fertility, AI centers should provide the over 60% motile sperm to the farms at the time of AI.

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

디지털방사선영상에서 추출한 해면질골의 강도와 미세구조의 형태계측학적 분석에 대한 연구 (A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image)

  • 한승윤;이선복;오성욱;허민석;이삼선;최순철;박태원;김종대
    • Imaging Science in Dentistry
    • /
    • 제33권2호
    • /
    • pp.113-119
    • /
    • 2003
  • Purpose : To evaluate the relationship between morphometric analysis of bone microstructure from digital radiographic image and trabecular bone strength. Materials and Methods : One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI (100 × 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1 mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Results: Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p < 0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p < 0.05). Conclusions : The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  • PDF

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

제도법 개선을 위한 저고리 깃 구성의 재고찰 (- The Review of the Collar Consideration of G go-ri to Improve Drafting Method -)

  • 정옥임
    • 대한가정학회지
    • /
    • 제34권4호
    • /
    • pp.249-263
    • /
    • 1996
  • According to the design method for constructing the G gori(the traditional Korean jacket)collar, there are differences in form after its completion. In the construction design of the midsection of the gusset as in that of the basic G gori, not only was the positioning of the two sides of the collar not smooth, but also, when the collar strip was attached, there would be an imbalance on one side or the other so that it was difficult to achieve symetry. Therefore in this project, by applying the pattern design of the gusset midsection to that of the collar midsection, not only did attaching the collar and the collar strip create a visual effect by equalizing the lengths of the tow sides, but the construction was also easy. This method of construction introduces the three-dimensional aspect of the human form in its conic, spherical and cylindrical aspects, so that, through schematizing the scientific character of Korea's clothing, its appropriateness is verified. As a matter of fact, since th-ere in no standardization of pattern whether for educational use or for mass-produced clothing, so that even the patterns used in computer-assisted design are executed according to the designer's personal skill, the reality is that after completion of construction the quality has not been uniform. For this schematization, inverse calculation of measurements pertaining to the calculation formula and of teaching materials has been referenced. In particular, the partial requlation of the calculation formula pertaining to the basic pattern construction, the method of making the collar midsection, and the construction method of the extreme and mean ratio adjustment can be adjusted for all measurements, thereby providing the establishment of a design criterion and the possibility of the standardization of construction methods. The production method for the pattern design is as follows: 1) The conic angle for the G gori's girth, length and neck width is fixed at 70 degrees. 2) The radius of the cone is B/2. 3) The calculation formula is B/4 + 1.5cm 4) The armhole formula is B/4, the same as in the basic method. 5) The width formula is B/10. 6) The ratio of the collar junction(width of collar + width of collar strip)to the gusset length is 5:8. 7) The length of the side seam is a length intersecting the armhole line and the conic radius (B/2), that is an arc that exceeds the length of the G gori's midsection; the component ratio of this length to the collar junction is accordingly 13:5. 8) The curve frame length of the back midsection is an arc exceeding B/4(the armhole line). 9) The ratio of the sleeve opening calculation formula to the armhole length is 8:5, forming an arc with the midsection length.

  • PDF

레일리 페이딩 채널에서 파일럿 기법과 LDPC 코딩이 적용된 COFDM-CDMA의 성능 분석 (Performance of pilot-assisted coded-OFDM-CDMA using low-density parity-check coding in Rayleigh fading channels)

  • 안영신;최재호
    • 한국통신학회논문지
    • /
    • 제28권5C호
    • /
    • pp.532-538
    • /
    • 2003
  • 본 논문에서는 다중 경로 이동통신 환경에서 LDPC 코드를 COFDM-CDMA에 적용하는 기법을 제안한다. LDPC 코드는 부호화율이 증가함에 따라 AWGN 채널이나 플랫 페이딩 채널에서는 우수한 복호화 성능을 나타내지만 수신 신호의 품질이 상대적으로 열악한 다중 경로 페이딩 채널의 경우에서는 LDPC 코딩의 성능 또한 상대적으로 저하된다. SNR이 16 ㏈ 이하인 다중 경로 이동통신 환경에서 부호화율이 1:3 이하인 LDPC 코드의 복호 기능을 만분의 일 이차의 BER로 낮추기 위해서는 LDPC 코드의 패리티 정보와 함께 COFDM-CDMA 수신기의 등화기 탭 값 갱신을 위한 채널 추정 파일럿 정보를 전송 심벌에 포함시켜야 한다. 예를 들어, 일반적인 1:3 LDPC 코드로 부호화된 전송 심벌의 데이터와 패리티의 비율이 1:3이라면 제안한 방식의 LDPC 채널 부호화기는 데이터, 패리티 및 파일럿의 비율이 1:2:1이 된다. 전송 심벌에 포함되는 파일럿 정보는 채널 추정 및 등화기 탭 값 갱신에 사용될 뿐 만 아니라 이 정보를 패리티 정보와 함께 LDPC 코드의 복호화에도 사용함으로써 동일한 데이터 전송율에서 1:3, LDPC 코드보다 더 우수한 성능을 얻을 수 있다. 다중 경로 레일리 페이딩 채널 환경에서 제안한 기법을 COFDM-CDMA 시스템에 적용하여 그 성능을 분석한 결과, 제안한 방식의 성능이 순수한 LDPC 코드를 적용한 시스템에 비하여 SRN 대 BER 측면에서 더 우수한 성능을 나타냄을 확인하였다.

클러스터 기반 무선 센서 망에서 트래픽 적응적 수면시간 기반 MAC 프로토콜 성능 분석 (Performance Evaluation of Traffic Adaptive Sleep based MAC in Clustered Wireless Sensor Networks)

  • 웅홍우;소원호
    • 전자공학회논문지CI
    • /
    • 제48권5호
    • /
    • pp.107-116
    • /
    • 2011
  • 본 논문에서는 무선 센서 망을 위한 트래픽 적응적 수면시간 기반 매체 접근 제어 (Traffic Adaptive Sleep based Medium Access Control; TAS-MAC) 프로토콜을 제안한다. 제안 된 프로토콜은 클러스터를 구성하는 센서노드에 적용되며 TDMA를 기본 방식으로 사용한다. 기존에 제시된 LEACH와 BMA-MAC과 같은 전형적인 스케줄링 방식을 사용하지만 입력 데이터가 없거나 주변으로부터 발생되는 이벤트 발생이 없는 긴 침묵시간을 고려한다. 이를 위하여 간단한 트래픽 측정기법을 사용하며 기존 중앙집중식 MAC에서 수행하는 불필요한 스케줄링 시간을 줄임으로서 에너지 소모를 적게 한다. 제안된 프로토콜의 프레임은 조사(I), 전송(T), 그리고 수면기간(S)로 구성되며 I-기간 동안 필요한 정보를 수집하여 긴 침묵 시간에 대응한 적당한 수면시간을 동적으로 결정한다. 또한 한 노드에서 클러스터 헤드로 전송할 데이터가 하나 이상일 때, T-기간 동안 다중의 데이터 전송이 가능하도록 TAS-MAC 프로토콜을 개선하여 데이터의 평균 전송 지연을 줄인다. 시뮬레이션을 통하여 에너지 소비와 전송 지연을 분석하고 기존 방식에 비해 에너지 효율이 향상됨을 보인다. 제안된 방식은 에너지 효율이 증가되면서 지연이 상대적으로 증가하는데 에너지 감소 요구를 만족시키는 방안도 논의한다.

고등학교 화학 교과서의 ‘용액’ 단원에 대한 입자 수준의 컴퓨터 보조 수업자료 개발 및 적용 효과 분석 (Development of Particle-level Computer Assisted Instruction Materials for the ‘Solution’ Chapter in High School Chemistry Textbook and Analysis of the Educational Effects)

  • 백성혜;김종현;김정원;박찬근
    • 대한화학회지
    • /
    • 제50권2호
    • /
    • pp.163-177
    • /
    • 2006
  • 본 연구에서는 전기화학적인 방법을 사용하여 Pt와 Ni 기판 상에 니켈 나이트레이트 용액을 사용하여 박막 형태의 알파 상 니켈 수산화물을 형성한 후 층간 존재하는 음이온의 종류와 농도에 따라 층상구조물의 층간 거리에 대해여 조사하였다. 층간 존재하는 나이트레이트 음이온과 양전하를 가진 층 사이의 정전 인력에 의하여 층간 거리(d003)는 층간 음이온의 농도에 역비례 하는 것으로 관찰되었으며, 특히 FT-IR 분석을 통하여 층간 거리가 감소한 경우 hydrogen-bonded OH만이 존재함을 확인하였다. GC-MS 분석 결과, 본 연구에 니켈 나이트레이트 용액을 사용하였음에도 불구하고 층간에 많은 량이 카보네이트 이온이 존재하는 것으로 조사되었다.

미세술기를 이용한 정계정맥류절제술이 정자 핵 내 DNA Integrity에 미치는 효과 (Effect of Microsurgical Varicocelectomy on Human Sperm Nucleus DNA Integrity)

  • 김기영;이재석;지희준;김종현
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제37권3호
    • /
    • pp.245-251
    • /
    • 2010
  • 목 적: 인간 정자 핵 내의 DNA integrity는 배아의 발달 및 임신 유지에 중요한 역할을 하여 DNA integrity가 손상된 경우 불임과 유산의 원인이 된다고 하며, 정계정맥류는 DNA 손상을 일으키는 대표적인 원인 중 하나이다. 본 연구에서는 미세술기를 이용한 정계정맥류절제술로 정계정맥류를 교정을 하였을 때 정자 핵 내 DNA integrity가 어떠한 영향을 받는지에 대하여 알아보았다. 연구방법: 2006년 4월부터 2007년 4월까지 불임을 주소로 미세술기를 이용한 정계정맥류절제술을 받았던 18명의 환자에서 수술 전 후에 정액검사의 다른 지표들과 함께 정자 핵 내 DNA integrity가 어떻게 변화하였는지 조사하였다. 정자 핵 내 DNA integrity를 측정하는 방법으로 comet assay를 시행하였고, comet assay를 통한 DNA 손상 정도는 DNA fragmentation index (DFI)로 나타내었다. 결 과: 수술 후 4개월에 모든 환자에서 재발의 소견은 보이지 않았으며, DNA 손상 정도를 나타내는 평균 DFI는 수술 전에 19.3%, 수술 후에 13.7%로 유의한 변화를 보였다. 수술 전 DFI가 10 이상으로 비정상인 14명의 환자들 중 12명 (85%)에서 개선 소견을 보였으나, 수술 전 DFI가 10 미만인 정상 환자 4명에서는 1명 (25%)만이 개선 소견을 보였다. 수술 후 정자의 밀도, 운동성, 생존성에서 호전 양상을 보였으나 유의한 차이는 없었다. 결 론: 미세술기를 이용한 정계정맥류절제술을 통한 수술적 교정은 정액검사상의 다른 지표의 개선 뿐 아니라, 정자 핵 내 DNA 손상을 감소시킬 수 있다. 이상에서 정계정맥류의 수술적 교정으로 정자 핵 내 DNA integrity의 개선을 기대할 수 있으며, 이는 보다 양호한 정자를 많이 얻을 수 있어 자연임신이나 보조 생식술의 성공 가능성을 높일 수 있다는 점을 제시한다.

마그네틱 나노비드를 이용한 돼지 정자 품질의 향상 (Improvement of Boar Semen Quality by Sperm Selection Using Magnetic Nano-particles)

  • 정기화;손종호
    • 생명과학회지
    • /
    • 제26권8호
    • /
    • pp.943-947
    • /
    • 2016
  • 본 연구는 간단히 활용할 수 있는 나노 크기의 마그네틱 비드를 이용하여 정자의 품질을 향상시킬 수 있는지 여부를 규명하기 위하여 실시하였다. 돼지 정자 시료는 인공수정 센터에서 공급받아 실험실로 2시간 이내로 이송한 후 CASA 측정을 통하여 4개의 활력을 나타내는 그룹으로(1, > 90%; 2. 80~90%; 3. 70~80%; 4. < 70%) 분류하였다. 정액은 BTS 희석제를 사용하여 보존하였고, 총 정자수와 동일한 농도의 마그네틱 비드를 정액에 20분간 처리한 후, 5분간 실온에서 마그네틱 비드에 반응한 정자를 자석을 이용하여 분리하였다. 마그네틱 비드 처리 전 과 후 정자의 생존율 및 활력은 CASA를 이용하여 측정하였고, 기형율과 정자응집의 정도는 현미경으로 검사하였다. 처리 후의 정자 활력은 4개 그룹 모두에서 유의하게(p<0.0.5) 높은 차이를 보였으며 처리 전에 비하여 평균 7.11% 향상되었다. 정자 활력의 변화는 처리 전 낮은 활력을 보인 그룹에서 보다 현저한 차이를 보였다(< 70% and 70~80%; 19.12±1.08% and 5.67±0.71%, p<0.0.5). 정자 활력을 VCL, VSL, VAP 및 LIN (%)로 구분한 성적에서도 유사한 패턴을 나타냈고, 이러한 현상은 활력 70% 이하를 나타낸 그룹에서 개선 효과가 더욱 뚜렷하였다. 마그네틱 비드 처리 후 정자 생존율은 처리 전에 비하여 평균 4%가 향상 되었고(p<0.0.5), 정자 기형율 또한 3.7~4.5%(p<0.0.5) 정도 감소하였다. 정자 응집의 정도 또한 마그네틱 비드 처리를 통하여 처리 전 낮은 활력을 나타낸 그룹에서 감소됨을 알 수 있었다.