• 제목/요약/키워드: computer-aided testing system

검색결과 28건 처리시간 0.025초

Feasibility Study of a Custom-made Film for End-to-End Quality Assurance Test of Robotic Intensity Modulated Radiation Therapy System

  • Kim, Juhye;Park, Kwangwoo;Yoon, Jeongmin;Lee, Eungman;Cho, Samju;Ahn, Sohyun;Park, Jeongeun;Choi, Wonhoon;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.189-195
    • /
    • 2016
  • This paper aims to verify the clinical feasibility of a custom-made film created by a laser cutting tool for End-to-End (E2E) quality assurance in robotic intensity modulated radiation therapy system. The custom-made film was fabricated from the Gafchromic EBT3 film with the size of $8^{{\prime}{\prime}}{\times}10^{{\prime}{\prime}}$ using a drawing that is identical to the shape and scale of the original E2E film. The drawing was created by using a computer aided design program with the image file, which is obtained by scanning original E2E film. Beam delivery and evaluations were respectively performed with the original film and the custom-made film using fixed-cone collimator on three tracking modes: 6D skull (6DS), Xsight spine (XS), and Xsight lung (XL). The differences between total targeting errors of the original and custom-made films were recorded as 0.17 mm, 0.3 mm, and 0.17 mm at 6DS, XS, and XL tracking modes, respectively. This indicates that the custom-made film could yield nearly equivalent results to those of the original E2E film, given the uncertainties caused by distortions during film scanning and vibrations associated with film cutting. By confirming the clinical feasibility of a custom-made film for E2E testing, it can be expected that economic efficiency of the testing will increase accordingly.

Lithium Disilicate (IPS e.max CAD) 코어와 전장 도재 사이의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Veneering Ceramics to the Lithium Disilicate (IPS e.max CAD) Core)

  • 김기백;김재홍
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.290-295
    • /
    • 2013
  • 본 연구는 심미 치과보철물에 사용되는 지르코니아, lithium disilicate 코어와 전장도재 사이의 전단결합강도를 측정하고, 금속도재관을 대조군으로 설정하여 비교하였다. 직사각기둥 모양의 시편을 각각 10개씩 제작하여 코어와 전장도재 사이의 전단결합강도를 측정한 후 파절면의 양상을 실체현미경을 통해 관찰하였다. 제한된 조건하에 시행된 실험을 통하여 심미보철 분야에 널리 적용되고 있는 치과용세라믹 코어의 전단결합강도를 확인하였으며, 측정 후 비교분석된 결과는 다음과 같다. 2종의 치과용 세라믹 코어와 전장도재 간에 전단결합강도는 금속도재관의 전단결합강도와 유의한 차이가 있었다 (p<0.05). 본 실험 결과를 토대로 ZB군은 임상적으로 받아들여지는 전단결합강도 범위 내 분포를 보이지만, LB군은 임상허용 범위에 못 미치는 결과값을 보였다. 금속도재관과 달리 지르코니아, lithium disilicate 전부도재관은 모두 혼합형 파절양상을 보였다. 결론적으로 전단결합강도 실험에 사용된 시편이 임상적인 치과보철물의 형태와는 달리 실험을 위한 시편의 형태로 제작되어 임상적 결과를 반영하지 못했으며 구강 내의 상황과도 다르다는 한계점을 가지고 있다. 추후에는 이를 보완하여 치과보철물과 유사한 형태의 시편을 이용한 전단결합 강도의 측정과 구강 내 조건을 고려한 추가 실험이 필요하다고 생각된다.

The Digital Mock-Up Information System for New Car Development

  • Min, Sung-Ki;Lee, Chul-Woo
    • 한국전자거래학회:학술대회논문집
    • /
    • 한국전자거래학회 1999년도 학술대회지 vol.1
    • /
    • pp.277-299
    • /
    • 1999
  • Since Chrysler Motor Co. had experienced the digital development system in the beginning of 1990's, most of leading automobile companies are trying to apply a digital information system for their own business process reengineering based upon concurrent engineering system from product planning phase. This is called as virtual DMU(Digital Mock-Up) system instead of the traditional PMU(Physical Mock-Up) system. By using the virtual prototype, all of the design requirements and system specifications can be checked, changed and optimized more quickly and more efficiently. This paper consists of five chapters for the DMU information system. In the 1$^{st}$ chapter, the principle of digital design system is suggested by using four basic modules such as product design module, process design module, manufacturing system design module and central control module. The basic scheme of DMU is introduced with the benefits of application in the chapter 2. In the chapter 3, a digital design process of new car development is explained with the detailed DMU design and design review processes. In the chapter 4, the practical DMU manufacturing techniques and applications are introduced as CAD/CAM analyses, DPA(Digital Pre-Assembly)reviews for development, production, operation and maintenance phases, digital tolerance analyses and digital factory analyses for assembling line simulation, automated robot welding processes, production jig & fixtures and painting process simulation. Finally, the activities of digital design support; CAS-styling, CAE-engineering and CAT-testing are summarized for design optimization in the chapter 5. As today's automobile manufactures and related business organizations are struggling to compete in the global marketplace, they are concentrating on efficient use of DMU information system to reduce the new car development cost, to have shorten the delivery schedule and to improve product design quality. To meet the demand of those automobile industries on digital information systems, the CALS(Computer aided Acquisition and Logistics Support) and EC(Electronic Commerce)initiative has been focused as a dominant philosophy in defense & commercial industries, specially automobile industries.s.

  • PDF

반도체 검사 장비를 위한 지능형 전자 성능 지원 시스템 (An Intelligent Electronic Performance Support System for Semiconductor Testing Equipment)

  • 이상용
    • 인지과학
    • /
    • 제9권1호
    • /
    • pp.31-39
    • /
    • 1998
  • 본 논문은 HELPS라는 반도체 검사 장비를 위한 전자성능지원시스템(Electronic Performance Support System)에 대하여 기술한다. 본 시스템의 목적은 운영 지원, 훈련, 지식 기반 고장 진단 및 수리를 위한 just-in time. on-the-job 멀티미디어에 기반을 둔 정보를 제공함으로써 오퍼레이터의 생산성을 향상시키는데 있다. HELPS는 운영 모듈과 고장 진단 모듈로 구성되어 있다. 운영 모듈은 사용자에게 장비에 관한 자세하고 쉽게 접근이 가능한 정보를 제공하기 위하여 멀티미디어와 하이퍼미디어를 사용한다. 멀티미디어는 정지 화상, 동화상, 에니메이션, 텍스트, 그래픽, 오디오를 포함하는 다매체 형식을 통합한다. 하이 퍼미디어는 계층적인 정보 구조를 통하여 숙련된 오퍼레이터에게는 작업을 수행하는데 필요한 특정한 정보만을 제공할 뿐만 아니라, 초보 오퍼레이터에게는 자세한 시스템 안내와 정보를 제공한다. 고장 진단 모듈은 오퍼레이터가 장비의 고장을 진단하고 수리하는 것을 자원하기 위하여 전문가 시스템과 멀티미디어를 통합하여 구성하였다. 전문가 시스템을 사용하여 진단한 다음, 멀티미디어에 의한 어드바이스가 텍스트를 포함한 정지 화상이나 음성을 포함한 동화상에 의해 제시된다. HELPS는 훈련 시간과 고장 진단 및 수리 시간의 측면에서 평가되었고, 본 시스템 사용 전에 비하여 약 30%이상의 시간을 절감함으로써 생산성 향상에 크게 도움이 된다는 것을 확인하였다. 앞으로 본 시스템은 ICAI와 가상현실 기법 등을 이용하여 확장된다면 더 많은 생산성 향상을 기대할 수 있을 것이다.

  • PDF

HMI 기능 시뮬레이션 기반 개인용 휴대전자제품의 가상시작 (Virtual Prototyping of Portable Consumer Electronic Products Based on HMI Functional Simulation)

  • 박형준;배채열;문희철;이관행
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2005년도 춘계공동학술대회 발표논문
    • /
    • pp.854-861
    • /
    • 2005
  • The functional behavior of a portable consumer electronic (PCE) product is nearly all expressed with human-machine interaction (HMI) tasks. Although physical prototyping and computer aided design (CAD) software can show the appearance of the product, they cannot properly reflect its functional behavior. In this paper, we propose a virtual prototyping (VP) system that incorporates virtual reality and HMI functional simulation in order to enables users to capture not only the realistic look of a PCE product but also its functional behavior. We obtain geometric part models of the product and their assembly and kinematics information with the help of CAD and reverse engineering tools, and visualize them with various display tools. We adopt state transition methodology to capture the HMI functional behavior of the product into a state transition chart, which is later used to construct a finite state machine (FSM) for the functional simulation of the product. The FSM plays an important role to control the transition between states of the product. The proposed VP system receives input events such as mouse clicks on buttons and switches of the virtual prototype model, and it reacts to the events based on the FSM by activating associated activities. The VP system provides the realistic visualization of the product and the vivid simulation of its functional behavior. It can easily allow users to perform functional evaluation and usability testing. Moreover, it can greatly reduce communication errors occurring in a typical product development process. A case study about VP of an MP3 player is given to show the usefulness of the proposed VP system.

  • PDF

Quatrz 웨이퍼의 직접접합과 극초단 레이저 가공을 이용한 체내 이식형 혈압센서 개발 (Development of Implantable Blood Pressure Sensor Using Quartz Wafer Direct Bonding and Ultrafast Laser Cutting)

  • 김성일;김응보;소상균;최지연;정연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.168-177
    • /
    • 2016
  • In this paper we present an implantable pressure sensor to measure real-time blood pressure by monitoring mechanical movement of artery. Sensor is composed of inductors (L) and capacitors (C) which are formed by microfabrication and direct bonding on two biocompatible substrates (quartz). When electrical potential is applied to the sensor, the inductors and capacitors generates a LC resonance circuit and produce characteristic resonant frequencies. Real-time variation of the resonant frequency is monitored by an external measurement system using inductive coupling. Structural and electrical simulation was performed by Computer Aided Engineering (CAE) programs, ANSYS and HFSS, to optimize geometry of sensor. Ultrafast laser (femto-second) cutting and MEMS process were executed as sensor fabrication methods with consideration of brittleness of the substrate and small radial artery size. After whole fabrication processes, we got sensors of $3mm{\times}15mm{\times}0.5mm$. Resonant frequency of the sensor was around 90 MHz at atmosphere (760 mmHg), and the sensor has good linearity without any hysteresis. Longterm (5 years) stability of the sensor was verified by thermal acceleration testing with Arrhenius model. Moreover, in-vitro cytotoxicity test was done to show biocompatiblity of the sensor and validation of real-time blood pressure measurement was verified with animal test by implant of the sensor. By integration with development of external interrogation system, the proposed sensor system will be a promising method to measure real-time blood pressure.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.

X-ray 영상에서 SegNet을 이용한 폐결핵 자동검출 시스템의 유용성 평가 (Evaluation on the Usefulness of X-ray Computer-Aided Detection (CAD) System for Pulmonary Tuberculosis (PTB) using SegNet)

  • 이주희;안현수;최동혁;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.25-31
    • /
    • 2017
  • Testing TB in chest X-ray images is a typical method to diagnose presence and magnitude of PTB lesion. However, the method has limitation due to inter-reader variability. Therefore, it is essential to overcome this drawback with automatic interpretation. In this study, we propose a novel method for detection of PTB using SegNet, which is a deep learning architecture for semantic pixel wise image labelling. SegNet is composed of a stack of encoders followed by a corresponding decoder stack which feeds into a soft-max classification layer. We modified parameters of SegNet to change the number of classes from 12 to 2 (TB or none-TB) and applied the architecture to automatically interpret chest radiographs. 552 chest X-ray images, provided by The Korean Institute of Tuberculosis, used for training and test and we constructed a receiver operating characteristic (ROC) curve. As a consequence, the area under the curve (AUC) was 90.4% (95% CI:[85.1, 95.7]) with a classification accuracy of 84.3%. A sensitivity was 85.7% and specificity was 82.8% on 431 training images (TB 172, none-TB 259) and 121 test images (TB 63, none-TB 58). This results show that detecting PTB using SegNet is comparable to other PTB detection methods.