• Title/Summary/Keyword: computer simulation program

Search Result 963, Processing Time 0.038 seconds

Development of the Pre-amplifier and the DSP Board for the Potable EEG Biofeedback System (포터블 뇌파 바이오피드백 시스템을 위한 전치증폭기 및 DSP 하드웨어의 설계)

  • Lee, Kyoung-Il;Ahn, Bo-Sep;Park, Jeong-Je;Lee, Seung-Ha;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.121-127
    • /
    • 2003
  • In this study, we carried out a study for implementation of the pre-amplifier and the digital signal processing part for the potable EEG biofeedback system. As we consider characteristics of the EEG signal, we designed the pre-amplifier to obtain the EEG signal to be reduced noise signal. Because the EEG signal include EOG, EMG, ECG signals etc, it is difficult to analyze of the EEG signal. Therefore, we developed DSP board and operation program which was embed the LMS adaptive filter algorithm and operate with the pre-amplifier in the real time. The simulation signal and pure EEG signal is used in the experiment. As the result, we confirmed good efficiency of developed system and possibility of application to the portable EEG biofeedback system.

Wideband Annular Ring Slot Microstrip Antenna with Concentric Radiating Structure (동심원 복사구조를 갖는 광대역 원형 링슬롯 마이크로스트립 안테나)

  • Shin, Ho-Sub;Kim, Nam;Rhee, Seung-Yeop;Ahn, Bierng-Chearl
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.9
    • /
    • pp.384-391
    • /
    • 2003
  • The wideband annular ring slot antenna with concentric radiating structure and low impedance feedline has been presented. This antenna has been analyzed in compensation for FR-4 substrate with relative permittivity 4.3 and thickness 1 mm. As the measured 10 dB impedance bandwidth of the proposed antenna is 127.2%(2.17∼9.76 GHz), its bandwidth is much broader than maximum 82% bandwidth of a conventional annular ring slot antenna. Experimental results from 2 to 10 GHz are shown to be in good agreement with the simulation. And this antenna has a high gain above 4 dBi from 2 GHz to 10 GHz as well as a 24% size reduction and 42% area reduction than a circular slot antenna.

Development of an Average Green Time Estimation Model for Proper Evaluation of Traffic Actuated Operation (감응식 신호운영의 평가를 위한 평균녹색시간 추정모형 개발)

  • KIM, Jin Tae;CHANG, Myungsoon;SON, Bongsoo;DOH, Tcheol Woong
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.3
    • /
    • pp.159-168
    • /
    • 2002
  • The Highway Capacity Manual(HCM) suggests estimating the average green time for the performance evaluation of the traffic actuated operation and Provides the average green time estimation model. However, the model provides with much room for improvements. This document proposes a new analytical model that overcomes the shortage of the HCM model. The average green times estimated by the HCM model and the proposed model were compared. A computer program using the proposed model was coded for the study, while the ACT348 program was used for the implementation of the HCM model Through the comparison study based on the 1,196 hypothetical simulation data surrogating field data, it was found that the average green times estimated by the proposed model yields much nicer one-to-one linear relationship to the simulation results than the ones from the HCM model in both exclusive-only and shared-permitted cases. The R2 values of the proposed and the HCM models with those cases are 0.90 and 0.56, and 0.86 and 0.57, respectively.

Production of Realistic Explosion Effects through Four Types of Solutions (4가지 솔루션을 통한 사실적인 폭발효과 제작)

  • Kim, Dong Sik;Hwang, Min Sik;Lee, Hyun Seok;Kim, Yong Hee;Yun, Tae Soo
    • Smart Media Journal
    • /
    • v.4 no.4
    • /
    • pp.120-129
    • /
    • 2015
  • Explosion effect on CG (Computer Graphic) a visual effect on which a higher degree of technological difficulty is required with a variety of effect elements such as Fire, Smoke, Flame, Dust, Debris, etc. integrated on it. As skills for CG software have been advanced, solutions loaded with functions of various fluid simulation have been developed. So more realistic special effects came to be available. However, in Korea, it depends just on CG program functions. Besides, enough R&D's concerned have not been followed up. Accordingly, this study is aimed at offering a production method that may effectively implement more realistic explosion effects under experimentations. To begin with, the study derives problems through a precedent study of the implementation of existing explosion effects. Then to solve them, experimental studies are performed depending on four solutions. There are accesses to the four solutions: first, Numerous Turbulent Flow, a method to allow an attribute of turbulent air in the stage of fluid simulation; second, Cache Retiming Solution produced in script; third, Multiple Volume Container based on cached data; and fourth, RGB Lighting Pipeline, a method to enhance the completion of the result from the stage of composition. Characteristics of effects applied in each stage and consecutive connections of them proved the effective implementation of more realistic explosion effects. This study may not only suppose the production method for efficient explosion effects differentiated from the previous ones but also be utilized as basic data for relevant researches.

A Study on the Thermo-Mechanical Stress of MEMS Device Packages (마이크로 머신(MEMS) 소자 패키지의 열응력에 대한 연구)

  • Jeon, U-Seok;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.744-750
    • /
    • 1998
  • Unlike common device, MEMS(micro-electro-mechanical system) device consists of very small mechanical structures which determine the performance of the device. Because of its small mechanical structure inside. MEMS device is very sensitive to thermal stress caused by CTE(coefficient of thermal expansion) mismatch between its components. Therefore, its characteristics are affected by material properties. process temperature. and dimensions of each layer such as chip, adhesive and substrate. In this study. we investigated the change of the thermal stress in the chip attached to a substrate. With computer-aided finite element method (FEM), the computer simulation of the thermal stress was conducted on variables such as bonding material, process temperature, bonding layer thickness and die size. The commercial simulation program, ABAQUS ver5.6, was used. Subsequently 3-layer test samples were fabricated, and their degree of bending were measured by 3-D coordinate measuring machine. The experimental results were in good agreement with the simulation results. This study shows that the bonding layer could be the source of stress or act as the buffer layer for stress according to its elastic modulus and CTE. Solder adhesive layer was the source of stress due to its high elastic modulus, therefore high compressive stress was developed in the chip. And the maximum tensile stress was developed in the adhesive layer. On the other hand, polymer adhesive layer with low elastic modulus acted as buffer layer, and resulted in lower compressive stress. The maximum tensile stress was developed in the substrate.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 2. 3-D VISUALIZATION AND MEASURMENT PROGRAM FOR MAXILLOFACIAL STRUCTURE- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -2. 악안면 구조에 대한 3차원적 시각화 및 측정프로그램 개발-)

  • Lee, Sang-Han;Mori, Yoshihide;Minami, Katsuhiro;Lee, Geun-Ho;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.321-329
    • /
    • 2001
  • To establish systematic diagnosis and treatment planning of dentofacial deformity patient including facial asymmetry or hemifacial microsomia patient, comprehensive analysis of three dimensional structure of the craniofacial skeleton is needed. Even though three dimensional CT has been developed, landmark identification of the CT is still questionable. In recent, a method for correcting cephalic malpositioning that enables accurate superimposition of the landmarks in different stages without using any additional equipment was developed. It became possible to compare the three-dimensional positional change of the maxillomandible without invasive procedure. Based on the principle of the method, a new program was developed for the purpose of diagnosis and treatment planning of dentofacial deformity patient via three dimensional visualization and structural analysis. This program enables us to perform following menu. First, visualization of three dimensional structure of the craniofacial skeleton with wire frame model which was made from the landmarks observed on both lateral and frontal cephalogram. Second, establishment of midsagittal plane of the face three dimensionally, with the concept of "the plane of the best-fit". Third, examination of the degree of deviation and direction of deformity of structure to the reference plane for the purpose of establishing surgical planning. Fourth, simulation of expected postoperative result by various image operation such as mirroring, overlapping.

  • PDF

Development of a Simulation Program for the Li-Reduction Process of PWR Spent Fuel (PWR 사용후핵연료의 Li 환원과정 모사 프로그램 개발)

  • Lee, Yun-Hee;Shin, Hee-Sung;Jang, Ji-Woon;Kim, Ho-Dong;Yoon, Ji-Sup
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.335-344
    • /
    • 2006
  • In this paper a computer program was developed, which simulates the Li reduction process of PWR spent fuel, and the amount of a produced metal or chloride compound was calculated at the various amount of Li with the program. It establishes a database, which is composed of some characteristics related to a chemical reaction equation and thermodynamic data, and it calculates the transformed rate of PWR spent fuel oxide at the certain amount of Li by using the database as input data. As the results of the performance test of the program, it was validated that the transformed values of oxides, except for $Eu_2O_3$ and $Sm_2O_3$, were almost the same to within about a 6 % error with those calculated by the previous code and that the calculated amount of Li was also exactly consistent with the theoretical one, which is used for a complete reaction of each oxide in a single chemical reaction. A relationship between Li and the transformed metal of each oxide was analyzed on the basis of the quantities calculated with the verified development program. Of the results, when the amount of Li was given to be 250 mole, the 83.73 percentage of $UO_2$ was transformed into U while the remainder was still to be $UO_2$. In addition, it was appeared that the 297 mole of Li was needed to completely convert $UO_2$ into U.

  • PDF

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.173-182
    • /
    • 1999
  • Contrast-enhanced CT has an important role in assessing liver lesions, the optimal protocol to get most effective result is not clear. The mein goal when deciding injention protocol is to optimize lesion detectability with rapid scanning when lesion to liver contrast is maximum. For this purpose, we developed a physiological model of the contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver is achieved in two paths. This dual supply characteristic distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and to second, by portal vein. However, it is assumed that only gepatic artery can supply blood to hepatocellular carcinoma(HCC) compartment, thus, the difference of contrast enhancement is resulted between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using the computer program Matlab, CT contrast-enhancement curves were simulated. The simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with the mean enhancement curves from 24 patients exposed to the same protocols as the simulation. These enhancement curves showed a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and the effects were analyzed. The variables to be considered in the injection protocol were injection rate, dose, and concentration of contrast material. These data may help to optimize scanning protocols for better diagnosis.

  • PDF

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF

A Study on Automotive Diagnostic System using CAN, CAN FD, FlexRay (CAN, CAN FD, FlexRay를 이용한 자동차용 진단시스템에 관한 연구)

  • Son, Chang-Koan;Oh, Se-Chun;Kim, Eui-Ryong;Kim, Sin-Ryeong;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.311-318
    • /
    • 2016
  • Recent vehicles are using car internal network for various purposes such as vehicle control, diagnostic functions, and ECU program upgrade. Currently CAN and FlexRay are the most representative networks. In the next-generation network, the use of CAN FD and car ethernet is actively studied. In this paper, we aimed to compare and evaluate the diagnostic function and the program of the ECU from the upgrade view on characteristics related to download time for each network when CAN, CAN FD, and FlexRay network are applied. As a result of the simulation, it was possible to determine that the CAN FD network is currently the most suitable for the next-generation network by suppressing other networks in terms of cost performance even under conditions of 500 Kbps and 2 Mbps which are practically usable speeds.