• Title/Summary/Keyword: computed tomography image

Search Result 980, Processing Time 0.027 seconds

The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion (골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구)

  • Kim, Moon-Hwan;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.389-403
    • /
    • 2008
  • In Angle's Class III malocclusion, which has higher incidence in Korean than Western, depressed midfacial profile with protruded lower lips and mandible may give rise to many functional, esthetic, psychological, social problems. Due to the different malocclusion incidence according to racial differences, many previous studies focused on the relationship between Class II malocclusion and nasal airway obstruction. Previous studies used lateral cephalography which has limitations of 2 dimensional image with projection error and identification error. Therefore, the purpose of this study was to analyze morphologic differences in the nasal airway between normal occlusion and Angle's Class III malocclusion patients using 3-dimensional facial computed tomography. Thirteen normal occlusion(7 men and 6 women) and sixteen skeletal Class III(7 men and 9 women) patients were selected and 3-dimensional facial computed tomography taking was performed. Comparison between two group in volume and sectional area of nasal airway were carried out. The results were followed. 1. In the comparison of absolute nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 2. In the comparison of relative nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 3. In the oropharyngeal space width on frontal and lateral view, the similar tendency was revealed between two groups. 4. In the lateral curvature of nasal airway, the similar tendency was revealed between two groups.

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

Imaging Anatomy of Waldeyer's Ring and PET/CT and MRI Findings of Oropharyngeal Non-Hodgkin's Lymphoma

  • Zhang, Chun-Xing;Liang, Long;Zhang, Bin;Chen, Wen-Bo;Liu, Hong-Jun;Liu, Chun-Ling;Zhou, Zheng-Gen;Liang, Chang-Hong;Zhang, Shui-Xing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3333-3338
    • /
    • 2015
  • Background: This study was conducted to analyze positron emission tomography (PET) / computed tomography (CT) and magnetic resonance imaging (MRI) performance with oropharyngeal non-Hodgkin's lymphoma (ONHL).Materials and Methods: The complete image data of 30 ONHL cases were analyzed, all patients were performed PET / CT and MRI examination before the treatment, with the time interval of these two inspections not exceeding 14 days. The distribution, morphology, MRI signal characteristics, enhancement feature, standardized uptake value (SUV) max value and lymph node metastasis way of the lesions were analyzed. Results: Among the 30 cases, 23 cases were derived from the B-cell (76.7%), 5 cases were derived from the peripheral T cells (16.7%) and 2 cases were derived from the NK/T cells (6.7%). 19 cases exhibited the palatine tonsil involvement (63.3%). As for the lesion appearance, 10 cases appeared as mass, 8 cases were the diffused type and 12 cases were the mixed type. 25 cases exhibited the SUVmax value of PET / CT primary lesions as 11 or more (83.3%). MRI showed that all patients exhibited various degrees of parapharyngeal side-compressed narrowing, but MRI still exhibited the high-signal fat, and the oropharyngeal mucosa was intact. 25 cases were associated with the neck lymph node metastasis, among who 22 cases had no necrosis in the metastatic lymph nodes, while the rest 3 cases exhibited the central necrosis in the metastatic lymph nodes. Conclusions: PET / CT and MRI have important value in diagnosing and determining the lesion extent of ONHL.

Intratumoral distribution of 64Cu-ATSM and 18F-FDG in VX2tumor xenografted rabbit

  • Yoo, Ran Ji;Lee, Ji Woong;Lee, Kyo Chul;An, Gwang Il;Ko, In Ok;Chung, Wee Sup;Park, Ji Ae;Kim, Kyeong Min;Choi, Yang-Kyu;Kang, Joo Hyun;Lim, Sang Moo;Lee, Yong Jin
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • $^{64}Cu$-labeled diacetyl-bis($N^4$-methylthiosemicarbazone) is a promising agent for internal radiation therapy and imaging of hypoxic tissues. In the study, we confirmed hypoxia regions in VX2 tumor implanted rabbits with injection $^{64}Cu$-ATSM and $^{18}F$-FDG using positron emission tomography (PET)/computed tomography (CT). PET images with $^{18}F$-FDG and $^{64}Cu$-ATSM were obtained for 40 min by dynamic scan and additional delayed PET images of $^{64}Cu$-ATSM the acquired up to 48 hours. Correlation between intratumoral $O_2$ level and $^{64}Cu$-ATSM PET image was analyzed. $^{64}Cu$-ATSM and $^{18}F$-FDG were intravenously co-injected and the tumor was dissected and cut into slices for a dual-tracer autoradiographic analysis. In the PET imaging, $^{64}Cu$-ATSM in VX2 tumors displayed a specific uptake in hypoxic region for48 h. The uptake pattern of $^{64}Cu$-ATSM in VX2 tumor at 24 and 48 h did not match to the $^{18}F$-FDG. Through ROI analysis, in the early phase (dynamic scan), $^{18}F$-FDG has positive correlation with $^{64}Cu$-ATSM but late phase (24 and 48 h) of the $^{64}Cu$-ATSM showed negative correlation with $^{18}F$-FDG. High uptake of $^{64}Cu$-ATSM in hypoxic region was responded with significant decrease of oxygen pressure, which confirmed by $^{64}Cu$-ATSM PET imaging and autoradiographic analysis. In conclusion, $^{64}Cu$-ATSM can utilize for specific targeting of hypoxic region in tumor, and discrimination between necrotic- and viable hypoxic tissue.

The Prognostic Value of 18F-Fluorodeoxyglucose PET/CT in the Initial Assessment of Primary Tracheal Malignant Tumor: A Retrospective Study

  • Dan Shao;Qiang Gao;You Cheng;Dong-Yang Du;Si-Yun Wang;Shu-Xia Wang
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.425-434
    • /
    • 2021
  • Objective: To investigate the potential value of 18F-fluorodeoxyglucose (FDG) PET/CT in predicting the survival of patients with primary tracheal malignant tumors. Materials and Methods: An analysis of FDG PET/CT findings in 37 primary tracheal malignant tumor patients with a median follow-up period of 43.2 months (range, 10.8-143.2 months) was performed. Cox proportional hazards regression analyses were used to assess the associations between quantitative 18F-FDG PET/CT parameters, other clinic-pathological factors, and overall survival (OS). A risk prognosis model was established according to the independent prognostic factors identified on multivariate analysis. A survival curve determined by the Kaplan-Meier method was used to assess whether the prognosis prediction model could effectively stratify patients with different risks factors. Results: The median survival time of the 37 patients with tracheal tumors was 38.0 months, with a 95% confidence interval of 10.8 to 65.2 months. The 3-year, 5-year and 10-year survival rate were 54.1%, 43.2%, and 16.2%, respectively. The metabolic tumor volume (MTV), total lesion glycolysis (TLG), maximum standardized uptake value, age, pathological type, extension categories, and lymph node stage were included in multivariate analyses. Multivariate analysis showed MTV (p = 0.011), TLG (p = 0.020), pathological type (p = 0.037), and extension categories (p = 0.038) were independent prognostic factors for OS. Additionally, assessment of the survival curve using the Kaplan-Meier method showed that our prognosis prediction model can effectively stratify patients with different risks factors (p < 0.001). Conclusion: This study shows that 18F-FDG PET/CT can predict the survival of patients with primary tracheal malignant tumors. Patients with an MTV > 5.19, a TLG > 16.94 on PET/CT scans, squamous cell carcinoma, and non-E1 were more likely to have a reduced OS.

Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images (심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출)

  • Kim, Hye-Ryun;Kang, Mi-Sun;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • Computed tomographic angiography (CTA) is widely used in the diagnosis and treatment of coronary artery disease because it shows not only the whole anatomical structure of the cardiovascular three-dimensionally but also provides information on the lesion and type of plaque. However, due to the large size of the image, there is a limitation in manually extracting coronary arteries, and related researches are performed to automatically extract coronary arteries accurately. As the coronary artery originate from the ascending aorta, the ascending aorta and ostium should be detected to extract the coronary tree accurately. In this paper, we propose an automatic segmentation for the ostium as a starting structure of coronary artery in CTA. First, the region of the ascending aorta is initially detected by using Hough circle transform based on the relative position and size of the ascending aorta. Second, the volume of interest is defined to reduce the search range based on the initial area. Third, the refined ascending aorta is segmented by using a two-dimensional geodesic active contour. Finally, the two ostia are detected within the region of the refined ascending aorta. For the evaluation of our method, we measured the Euclidean distance between the result and the ground truths annotated manually by medical experts in 20 CTA images. The experimental results showed that the ostia were accurately detected.

Determination of Early Graft Patency Using CT Angiography after Coronary Artery Bypass Surgery (관상동맥우회술 후 CT 조영술을 이용한 이식편의 조기 열림의 판정)

  • 이미경;류대웅;최순호;최종범
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.570-577
    • /
    • 2004
  • CT angiography is now available to evaluate the early graft patency after coronary bypass surgery. We investigated whether patency or occlusion of the bypass grafts can be visualized by CT angiography and what factors effect the visuality. Material and Method: Fifty patients underwent scanning with a 4-slice computed tomographic scanner (Somatom Volume ZoomTM; Siemens, Germany) before being discharged after coronary artery bypass grafting. To evaluate graft patency and relationship between the quality of graft image and the characteristics of the diseased coronary vessels, 50 internal thoracic artery grafts, 18 radial artery grafts, and 56 vein grafts were included in this study. Result: All vein grafts (24 grafts; 32 anastomoses) to left coronary artery system were well visualized, but 3 grafts (4.7%) of 30 vein grafts (35 anastomoses) to right coronary artery system were not visualized. The latter was also occluded in invasive coronary angiographic study. Thirty-nine (78%) internal thoracic artery grafts were well visualized, 8 (16%) faintly visualized, and 3 (6%) not visualized, but all the internal artery grafts were well patent in invasive coronary angiographic study. Conclusion: Unvisualized vein grafts in CT angiography means occlusion of the grafts, but unvisualized arterial grafts in CT angiography may not mean occlusion of the graft but result from competitive flow between the graft and coronary artery. To confirm patency of the unvisualized arterial grafts, invasive coronary angiography is needed.

New method of assessing the relationship between buccal bone thickness and gingival thickness

  • Kim, Yun-Jeong;Park, Ji-Man;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Rhyu, In-Chul;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.372-381
    • /
    • 2016
  • Purpose: The aim of this study was to determine the relationship between buccal bone thickness and gingival thickness by means of a noninvasive and relatively accurate digital registration method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomographic images and intraoral scanned files were obtained. Measurements of buccal bone thickness and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. The Friedman test was used to compare buccal bone and gingival thickness for each depth between the 3 tooth types. Spearman's correlation coefficient was calculated to assess the correlation between buccal bone thickness and gingival thickness. Results: Of the central incisors, 77% of all sites had a buccal thickness of 0.5-1.0 mm, and 23% had a thickness of 1.0-1.5 mm. Of the lateral incisors, 71% of sites demonstrated a buccal bone thickness <1.0 mm, as did 63% of the canine sites. For gingival thickness, the proportion of sites <1.0 mm was 88%, 82%, and 91% for the central incisors, lateral incisors, and canines, respectively. Significant differences were observed in gingival thickness at the alveolar crest level (G0) between the central incisors and canines (P=0.032) and between the central incisors and lateral incisors (P=0.013). At 1 mm inferior to the alveolar crest, a difference was found between the central incisors and canines (P=0.025). The lateral incisors and canines showed a significant difference for buccal bone thickness 5 mm under the alveolar crest (P=0.025). Conclusions: The gingiva and buccal bone of the anterior maxillary teeth were found to be relatively thin (<1 mm) overall. A tendency was found for gingival thickness to increase and bone thickness to decrease toward the root apex. Differences were found between teeth at some positions, although the correlation between buccal bone thickness and soft tissue thickness was generally not significant.

The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study (약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구)

  • Bitbyeol Kim;Ho Kyung Kim;Jinsung Kim;Yongkan Ki;Ji Hyeon Joo;Hosang Jeon;Dahl Park;Wontaek Kim;Jiho Nam;Dong Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1477-1492
    • /
    • 2021
  • Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. Materials and Methods Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student's t test. Results Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. Conclusion The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.