• Title/Summary/Keyword: computed tomography, CT

Search Result 2,595, Processing Time 0.041 seconds

Comparison of dental radiography and computed tomography: measurement of dentoalveolar structures in healthy, small-sized dogs and cats

  • Lee, Seunghee;Lee, Kichang;Kim, Hyeona;An, Jeongsu;Han, Junho;Lee, Taekwon;Jeong, Hogyun;Cho, Youngkwon
    • Journal of Veterinary Science
    • /
    • v.21 no.5
    • /
    • pp.75.1-75.8
    • /
    • 2020
  • Background: Dental diseases are common in dogs and cats, and accurate measurements of dentoalveolar structure are important for planning of treatment. The information that the comparison computed tomography (CT) with dental radiography (DTR) is not yet reported in veterinary medicine. Objectives: The purpose of this study was to compare the DTR with CT of dentoalveolar structures in healthy dogs and cats, and to evaluate the CT images of 2 different slice thicknesses (0.5 and 1.0 mm). Methods: We included 6 dogs (2 Maltese and 1 Spitz, Beagle, Pomeranian, mixed, 1 to 8 years, 4 castrated males, and 2 spayed female) and 6 cats (6 domestic short hair, 8 months to 3 years, 4 castrated male, and 2 spayed female) in this study. We measured the pulp cavity to tooth width ratio (P/T ratio) and periodontal space of maxillary and mandibular canine teeth, maxillary fourth premolar, mandibular first molar, maxillary third premolar and mandibular fourth premolar. Results: P/T ratio and periodontal space in the overall dentition of both dogs and cats were smaller in DTR compared to CT. In addition, CT images at 1.0 mm slice thickness was generally measured to be greater than the images at 0.5 mm slice thickness. Conclusions: The results indicate that CT with thin slice thickness provides more accurate information on the dentoalveolar structures. Additional DTR, therefore, may not be required for evaluating dental structure in small-sized dogs and cats.

Usefulness of Computed Tomography Gastrography in the Surgical Management of a Gastric GIST (위에 발생한 위장관간질종양의 수술적 치료에서 Computed Tomogrophy Gastrography의 유용성)

  • Han, Dong-Seok;Lee, Hyuk-Joon;Lee, Min-Woo;Kim, Se-Hyung;Lee, Kuhn-Uk;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.207-213
    • /
    • 2006
  • Purpose: This study was performed to evaluate the usefulness of computed tomography (CT) gastrography in the surgical management of a gastric gastrointestinal stromal tumor (GIST). Materials and Methods: We retrospectively analyzed the clinicopathologic data of 38 patients who had undergone CT gastrography from among patients who had gastric GISTS surgically resected at the Department of Surgery, Seoul National University Hospital, between January 2001 and February 2006. We compared CT gastrography data, including tumor size and location and distance from the gastroesophageal junction or pylorus with endoscopic, surgical and pathologic findings. Results: The longitudinal tumor locations on CT gastrography and endoscopy were identical to the surgical findings. For tumor sizes on CT gastrography of less than 5 cm, we performed 11 (42.3%) laparoscopic wedge resections from among 26 cases. In the 12 cases with tumor sizes of 5 cm or over, only 1 (8.3%) laparoscopic wedge resection was performed. When the tumor was located in the middle third of the stomach, a laparoscopic wedge resection was performed in 88.9% (8/9) of the cases, but when it was located in the upper or lower third, a laparoscopic wedge resection was performed in only 13.8% (4/29) of the cases. Conclusion: Three-dimensional information from CT gastrography allows the surgeon to perform preoperative planning, including accurate localization.

  • PDF

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.

Analysis of Particle Rearrangement during Sintering by Micro Focus Computed Tomography $({\mu}CT)$

  • Nothe, M.;Schulze, M.;Grupp, R.;Kieback, B.;Haibel, A.;Banhart, J.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.808-809
    • /
    • 2006
  • The decrease of the distance between particle centers due to the growth of the sinter necks can be explained by the well known two-particle model. Unfortunately this model fails to provide a comprehensive description of the processes for 3D specimens. Furthermore, there is a significant discrepancy between the calculated and the measured shrinkage because particle rearrangements are not considered. Only the recently developed analysis of the particle movements inside of 3D specimens using micro focus computed tomography $({\mu}CT)$, combined with photogrammetric image analysis, can deliver the necessary experimental data to improve existing sintering theories. In this work, ${\mu}CT$ analysis was applied to spherical copper powders. Based on photogrammetric image analysis, it is possible to determine the positions of all particle centers for tracking the particles over the entire sintering process and to follow the formation and breaking of the particle bonds. In this paper, we present an in-depth analysis of the obtained data. In the future, high resolution synchrotron radiation tomography will be utilized to obtain in-situ data and images of higher resolution.

  • PDF

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

Rupturing Anterior Communicating Artery Aneurysm during Computed Tomography Angiography : Three-Dimensional Visualization of Bleeding into the Septum Pellucidum and the Lateral Ventricle

  • Kim, Ealmaan
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.6
    • /
    • pp.357-361
    • /
    • 2014
  • Computed tomography angiography (CTA) is commonly used in setting of subarachnoid hemorrhage, but imaging features of aneurysm rupturing taking place at the time of scanning has rarely been described. The author reports a case of actively rebleeding aneurysm of the anterior communicating artery with intraventricular extravasation on the hyperacute CTA imaging. The rebleeding route, not into the third ventricle but into the lateral ventricles, can be visualized by real-time three-dimensional CT pictures. The hemorrhage broke the septum pellucidum and the lamina rostralis rather than the lamina terminalis.

Basic principle of cone beam computed tomography (Cone beam형 전산화단층영상의 원리)

  • Choi Yong-Suk;Kim Gyu-Tae;Hwang Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.123-129
    • /
    • 2006
  • The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography (CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems.

  • PDF

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.

Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model (CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Um Ki-Doo;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF