• Title/Summary/Keyword: computed tomography, CT

Search Result 2,635, Processing Time 0.026 seconds

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

The Use of Brain Computer Tomography Examination with Mild Traumatic Brain Injury in Pediatrics (일개 대학병원에서 경험한 소아의 경증 두부 외상에서 Brain CT 측정 및 효용성)

  • Kim, Ha Kyung;Kim, Jin Joo;Cho, Jin Seong;Jang, Jae Ho;Yang, Hyuk Jun;Lee, Gun
    • Journal of Trauma and Injury
    • /
    • v.27 no.3
    • /
    • pp.63-70
    • /
    • 2014
  • Purpose: In children, mild traumatic brain injuries (TBI) account for 70~90% of head injuries. Without guidelines, many of these children may be exposed to excess radiation due to unnecessary imaging. The purpose of this study was to evaluate the impact of a mild TBI guideline in imaging of pediatric patients. Methods: The medical records of all children who had head computed tomography and were admitted to our hospital with a TBI with Pediatric Glasgow Coma Scale and Glasgow Coma Scale of 14 to 15 were retrospectively reviewed and compared with PECARN Rule. Results: A total of 1260 children were included and all children checked with head computed tomography. 61 pediatrics had CT positive and presented skull fracture 40, hemorrhage 8, hemorrhagic contusion 7, and diffuse axonal injury 1. Also, 4 patients diagnosed both skull fracture and brain haemorrhage and 1 patient diagnosed both haemorrhage and haemorrhagic contusion. Conclusion: There are many pediatric traumatic patients who exposed to radiation due to CT. But, the most of results were negative. So, consider to follow the CT guideline for children and many do not require brain CT.

Variable uterine uptake of FDG in adenomyosis during concurrent chemoradiation therapy for cervical cancer

  • Yu, Jeong-Il;Huh, Seung-Jae;Kim, Young-Il;Kim, Tae-Joong;Park, Byung-Kwan
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.214-217
    • /
    • 2011
  • To avoid improper tumor volume contouring in radiation therapy (RT) and other invasive procedures, we report a case of uterine adenomyosis showing increased $^{18}F$-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET)/computed tomography (CT) mimicking malignant tumor in a 44-year-old woman during concurrent chemoradiation therapy (CCRT) for uterine cervical cancer. The adenomyosis was not associated with her menstrual cycle or with normal endometrium uptake, and it resolved one month after completion of RT. This case indicates that uterine adenomyosis in a premenopausal woman may show false positive uptake of $^{18}FDG$-PET/CT associated with CCRT.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

Dynamic CT Finding of Pelioid HCC ; Case Report (자색반형 간세포암종의 Dynamic CT 영상소견; 증례보고)

  • Son, Rak-Chae;Kim, Jae-Woon;Chang, Jae-Chun
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.146-149
    • /
    • 2010
  • Pelioid hepatocellular carcinoma(HCC), a type of atypical HCC, is a rare histologic type of HCC. The radiologic findings of the pelioid HCC is differ from the typical type of HCC. To our knowledge, this case report is the second literature to show the enhancing features of a pelioid HCC on dynamic computed tomography (CT).Here we describe the dynamic CT findings in a case of surgically confirmed pelioid HCC.

  • PDF

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

Cone beam CT findings of retromolar canals: Report of cases and literature review

  • Han, Sang-Sun;Park, Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.309-312
    • /
    • 2013
  • A retromolar canal is an anatomical variation in the mandible. As it includes the neurovascular bundle, local anesthetic insufficiency can occur, and an injury of the retromolar canal during dental surgery in the mandible may result in excessive bleeding, paresthesia, and traumatic neuroma. Using imaging analysis software, we evaluated the cone-beam computed tomography (CT) images of two Korean patients who presented with retromolar canals. Retromolar canals were detectable on the sagittal and cross-sectional images of cone-beam CT, but not on the panoramic radiographs of the patients. Therefore, the clinician should pay particular attention to the identification of retromolar canals by preoperative radiographic examination, and additional cone beam CT scanning would be recommended.

Contrast Enhanced Ultrasonography and CT Features of Gastrointestinal Stromal Tumor in a Dog

  • Saran Chhoey;Soyeon Kim;Kroesna Kang;Sath Keo;Jihye Choi
    • Journal of Veterinary Clinics
    • /
    • v.40 no.5
    • /
    • pp.375-381
    • /
    • 2023
  • A large abdominal mass was incidentally found in a 13-year-old mixed-breed dog and was confirmed to be a cecal gastrointestinal stromal tumor (GIST). Contrast-enhanced ultrasound and post-contrast computed tomography (CT) showed mild contrast enhancement of the mass, indicating low blood flow. The tumor origin was determined to be the cecum by identifying the vessels supplying the mass on post-contrast CT. The exophytic growth of the tumor left the cecal lumen intact without obstruction. This report described the CEUS and CT perfusion of the cecal GIST and perfusion evaluation can help diagnose and characterize GISTs in dogs.

Temporomandibular Joint False Ankylosis in a Cat: A Case Report

  • Sanghyeon Yoon;Jung-Ha Lee;Seo-Eui Lee;Hakyoung Yoon
    • Journal of Veterinary Clinics
    • /
    • v.40 no.5
    • /
    • pp.365-369
    • /
    • 2023
  • Temporomandibular joint (TMJ) ankylosis is a rare disease impairing mandible movement and can either be intra-articular (true) or extra-articular (false). A cat presented with an inability to open its mouth, drooling, and facial asymmetry. Computed tomography (CT) confirmed an extracapsular abnormal TMJ fusion, and a surgical plan was devised based on the CT imaging. Post-surgery, the cat regained mouth mobility (indicating false ankylosis) and showed an improved prognosis. This case of CT-diagnosed and treated feline TMJ false ankylosis underscores the indispensable role of CT in diagnosing and devising surgical strategies for feline TMJ false ankylosis.

Halo, Reversed Halo, or Both? Atypical Computed Tomography Manifestations of Coronavirus Disease (COVID-19) Pneumonia: The "Double Halo Sign"

  • Antonio Poerio;Matilde Sartoni;Giammichele Lazzari;Michele Valli;Miria Morsiani;Maurizio Zompatori
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1161-1164
    • /
    • 2020
  • The epidemic of 2019 novel coronavirus, later named as coronavirus disease (COVID-19), began in Wuhan, China in December 2019 and has spread rapidly worldwide. Early diagnosis is crucial for the management of the patients with COVID-19, but the gold standard diagnostic test for this infection, the reverse transcriptase polymerase chain reaction, has a low sensitivity and an increased turnaround time. In this scenario, chest computed tomography (CT) could play a key role for an early diagnosis of COVID-19 pneumonia. Here, we have reported a confirmed case of COVID-19 with an atypical CT presentation showing a "double halo sign," which we believe represents the pathological spectrum of this viral pneumonia.