• 제목/요약/키워드: computed tomography, CT

검색결과 2,531건 처리시간 0.031초

콘빔 CT를 이용한 한국인의 하악 절치관 평가 (Assessment of mandibular incisive canal using cone-beam computed tomography in Korean population)

  • 조봉혜;정연화
    • 대한치과의사협회지
    • /
    • 제53권12호
    • /
    • pp.967-974
    • /
    • 2015
  • Purpose: This study was performed to investigate the characteristics of mandibular incisive canal (MIC) in Korean population. Materials and methods: A total of 97 subjects (60 males and 37 females) who underwent cone-beam computed tomography were included in the study. The anatomic features of MIC was assessed according to gender. Length, diameter and distance to inferior, lingual and buccal border were measured at the origin and the terminal. Also the distribution of MIC at each tooth position was evaluated. Results: Of 97 patients included, 75(77.3%) presented bilateral MIC and 13(13.4%) presented unilateral MIC. Of 194 hamimandibles, MIC was detected in 102(85%) sites in male and 61(82.4%) sites in female. Gender and side showed no statistically significant differences in detectability. The length, diameter and distance to adjacent structures were bigger in male than in female except the distance to lingual border. MIC travelled anteriorly in a slightly downward and lingual direction and usually terminated between the first premolar and the canine. On cross-sectional view, MIC showed individually scattered distribution both buccolingually and superoinferiorly. Conclusion: MIC is well detected with cone-beam computed tomography. Considered that the length and the location of MIC has large variations between individuals, its localization using cone-beam CT is highly recommended before performing surgical procedures such as implant placement and bone harvesting.

전산화 단층촬영에 의한 니들펀칭 탄소/탄소 복합재료 노즐 목삽입재의 밀도 분포 평가 (Density Profile Evaluation of Needle-punched Carbon/Carbon Composites Nozzle Throat by the Computed Tomography)

  • 김동륜;윤남균;이진용
    • 한국추진공학회지
    • /
    • 제10권1호
    • /
    • pp.44-53
    • /
    • 2006
  • 전산화 단층촬영법을 이용하여 탄소/탄소 목삽입재의 밀도 분포를 평가하였다. 전산화 단층촬영법의 Team hardening, 전기적 잡음 및 산란 X-ray의 영상을 보정하고 신호 대 잡음비를 높여 최적화할 때 측정된 탄소/탄소 복합재료의 밀도는 98.74%의 신뢰도 수준에서 ${\pm}0.01g/cm^3$ 분포를 갖는 것으로 평가되었다. 전산화 단층촬영 결과의 검증은 탄소/탄소 목삽입재를 절단하여 수침법에 의한 밀도 측정과 주사전자현미경 관찰을 통하여 수행되었으며 단층촬영 결과는 수침법에 의한 밀도 분포와 주사전자현미경의 영상과 일치하였다.

Temporomandibular Joint Ankylosis Caused by Osteoarthritis: A Case Report Based on Cone Beam Computed Tomography Images

  • Jih, Myeong Kwan;Kim, Jin Soo;Park, Hyun-Jeong
    • Journal of Oral Medicine and Pain
    • /
    • 제47권3호
    • /
    • pp.156-160
    • /
    • 2022
  • Temporomandibular joint (TMJ) ankylosis is a condition in which condylar movement is restricted because of fibrous or bony union between the mandibular condyle and temporal bone. TMJ ankylosis is most often caused by trauma, followed by systemic or local infection, and secondary to unknown causes. Diagnostic imaging plays a vital role in diagnosing TMJ ankylosis and establishing a treatment plan. Computed tomography (CT) or cone beam computed tomography (CBCT) is currently the imaging technique of choice to accurately demonstrate preoperative ankylosing masses and other surgically important findings, such as the shape of the mandibular condyle and the pathological changes in the joint. The osseous changes in the mandibular condyle are easily identified in the coronal and sagittal sections of CT or CBCT images. This report describes the case of a middle-aged woman who developed TMJ ankylosis of the left TMJ while undergoing repeated treatment for TMJ disease. We report the findings observed on radiographic and CBCT images through continuous observation.

갑상선 유두암의 외측 경부림프절 전이에 대한 수술 전 평가로서 CT의 역할 (The Role of CT as a Preoperative Evaluation of Lateral Cervical Lymph Node Metastasis in Papillary Thyroid Carcinoma)

  • 석준걸;김형규;김윤중;한규희;안순현
    • 대한두경부종양학회지
    • /
    • 제29권2호
    • /
    • pp.37-40
    • /
    • 2013
  • Background and Objectives : To assess the usefulness of computed tomography image before papillary thyroid cancer surgery, focus on confirmation of lateral cervical lymph node metastasis not detected by ultrasonography. Material and Methods : From January 2008 to May 2009, total 150 patients who had undergone thyroid surgery and been confirmed papillary thyroid cancer pathologically were enrolled. They had taken neck computed tomography following the ultrasonography. Results : Computed tomography had found suspicious metastatic lateral neck lesion in 13 patients. After the image study, lateral neck lymph node dissection had been included in their surgical plan. Of these, only 7 cases were confirmed pathologically lateral neck lymph node metastasis(positive predictive value=0.54). Taken as whole 150 patients, additionally 4.7% of patients confirmed lateral neck lymph node metastasis by preoperative computed tomography. Conclusion : If preoperative ultrasonography was performed precisely, additional benefits that could be achieved by computed tomography were not much.

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

일개 대학병원에서 경험한 소아의 경증 두부 외상에서 Brain CT 측정 및 효용성 (The Use of Brain Computer Tomography Examination with Mild Traumatic Brain Injury in Pediatrics)

  • 김하경;김진주;조진성;장재호;양혁준;이근
    • Journal of Trauma and Injury
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2014
  • Purpose: In children, mild traumatic brain injuries (TBI) account for 70~90% of head injuries. Without guidelines, many of these children may be exposed to excess radiation due to unnecessary imaging. The purpose of this study was to evaluate the impact of a mild TBI guideline in imaging of pediatric patients. Methods: The medical records of all children who had head computed tomography and were admitted to our hospital with a TBI with Pediatric Glasgow Coma Scale and Glasgow Coma Scale of 14 to 15 were retrospectively reviewed and compared with PECARN Rule. Results: A total of 1260 children were included and all children checked with head computed tomography. 61 pediatrics had CT positive and presented skull fracture 40, hemorrhage 8, hemorrhagic contusion 7, and diffuse axonal injury 1. Also, 4 patients diagnosed both skull fracture and brain haemorrhage and 1 patient diagnosed both haemorrhage and haemorrhagic contusion. Conclusion: There are many pediatric traumatic patients who exposed to radiation due to CT. But, the most of results were negative. So, consider to follow the CT guideline for children and many do not require brain CT.

Variable uterine uptake of FDG in adenomyosis during concurrent chemoradiation therapy for cervical cancer

  • Yu, Jeong-Il;Huh, Seung-Jae;Kim, Young-Il;Kim, Tae-Joong;Park, Byung-Kwan
    • Radiation Oncology Journal
    • /
    • 제29권3호
    • /
    • pp.214-217
    • /
    • 2011
  • To avoid improper tumor volume contouring in radiation therapy (RT) and other invasive procedures, we report a case of uterine adenomyosis showing increased $^{18}F$-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET)/computed tomography (CT) mimicking malignant tumor in a 44-year-old woman during concurrent chemoradiation therapy (CCRT) for uterine cervical cancer. The adenomyosis was not associated with her menstrual cycle or with normal endometrium uptake, and it resolved one month after completion of RT. This case indicates that uterine adenomyosis in a premenopausal woman may show false positive uptake of $^{18}FDG$-PET/CT associated with CCRT.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

자색반형 간세포암종의 Dynamic CT 영상소견; 증례보고 (Dynamic CT Finding of Pelioid HCC ; Case Report)

  • 손락채;김재운;장재천
    • Journal of Yeungnam Medical Science
    • /
    • 제27권2호
    • /
    • pp.146-149
    • /
    • 2010
  • Pelioid hepatocellular carcinoma(HCC), a type of atypical HCC, is a rare histologic type of HCC. The radiologic findings of the pelioid HCC is differ from the typical type of HCC. To our knowledge, this case report is the second literature to show the enhancing features of a pelioid HCC on dynamic computed tomography (CT).Here we describe the dynamic CT findings in a case of surgically confirmed pelioid HCC.

  • PDF

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.