• Title/Summary/Keyword: computed tomography(CT)

Search Result 2,598, Processing Time 0.037 seconds

Preoperative Assessment of Renal Sinus Invasion by Renal Cell Carcinoma according to Tumor Complexity and Imaging Features in Patients Undergoing Radical Nephrectomy

  • Ji Hoon Kim;Kye Jin Park;Mi-Hyun Kim;Jeong Kon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1323-1331
    • /
    • 2021
  • Objective: To identify the association between renal tumor complexity and pathologic renal sinus invasion (RSI) and evaluate the usefulness of computed tomography tumor features for predicting RSI in patients with renal cell carcinoma (RCC). Materials and Methods: This retrospective study included 276 consecutive patients who underwent radical nephrectomy for RCC with a size of ≤ 7 cm between January 2014 and October 2017. Tumor complexity and anatomical renal sinus involvement were evaluated using two standardized scoring systems: the radius (R), exophytic or endophytic (E), nearness to collecting system or sinus (N), anterior or posterior (A), and location relative to polar lines (RENAL) nephrometry and preoperative aspects and dimensions used for anatomical classification (PADUA) system. CT-based tumor features, including shape, enhancement pattern, margin at the interface of the renal sinus (smooth vs. non-smooth), and finger-like projection of the mass, were also assessed by two independent radiologists. Univariable and multivariable logistic regression analyses were performed to identify significant predictors of RSI. The positive predictive value, negative predictive value (NPV), accuracy of anatomical renal sinus involvement, and tumor features were evaluated. Results: Eighty-one of 276 patients (29.3%) demonstrated RSI. Among highly complex tumors (RENAL or PADUA score ≥ 10), the frequencies of RSI were 42.4% (39/92) and 38.0% (71/187) using RENAL and PADUA scores, respectively. Multivariable analysis showed that a non-smooth margin and the presence of a finger-like projection were significant predictors of RSI. Anatomical renal sinus involvement showed high NPVs (91.7% and 95.2%) but low accuracy (40.2% and 43.1%) for RSI, whereas the presence of a non-smooth margin or finger-like projection demonstrated comparably high NPVs (90.0% and 91.3% for both readers) and improved accuracy (67.0% and 73.9%, respectively). Conclusion: A non-smooth margin or the presence of a finger-like projection can be used as a preoperative CT-based tumor feature for predicting RSI in patients with RCC.

Subjective and Objective Assessment of Monoenergetic and Polyenergetic Images Acquired by Dual-Energy CT in Breast Cancer

  • Xiaoxia Wang;Daihong Liu;Shixi Jiang;Xiangfei Zeng;Lan Li;Tao Yu;Jiuquan Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.502-512
    • /
    • 2021
  • Objective: To objectively and subjectively assess and compare the characteristics of monoenergetic images [MEI (+)] and polyenergetic images (PEI) acquired by dual-energy CT (DECT) of patients with breast cancer. Materials and Methods: This retrospective study evaluated the images and data of 42 patients with breast cancer who had undergone dual-phase contrast-enhanced DECT from June to September 2019. One standard PEI, five MEI (+) in 10-kiloelectron volt (keV) intervals (range, 40-80 keV), iodine density (ID) maps, iodine overlay images, and Z effective (Zeff) maps were reconstructed. The contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) were calculated. Multiple quantitative parameters of the malignant breast lesions were compared between the arterial and the venous phase images. Two readers independently assessed lesion conspicuity and performed a morphology analysis. Results: Low keV MEI (+) at 40-50 keV showed increased CNR and SNRbreast lesion compared with PEI, especially in the venous phase ([CNR: 40 keV, 20.10; 50 keV, 14.45; vs. PEI, 7.27; p < 0.001], [SNRbreast lesion: 40 keV, 21.01; 50 keV, 16.28; vs. PEI, 10.77; p < 0.001]). Multiple quantitative DECT parameters of malignant breast lesions were higher in the venous phase images than in the arterial phase images (p < 0.001). MEI (+) at 40 keV, ID, and Zeff reconstructions yielded the highest Likert scores for lesion conspicuity. The conspicuity of the mass margin and the visual enhancement were significantly better in 40-keV MEI (+) than in the PEI (p = 0.022, p = 0.033, respectively). Conclusion: Compared with PEI, MEI (+) reconstructions at low keV in the venous phase acquired by DECT improved the objective and subjective assessment of lesion conspicuity in patients with malignant breast lesions. MEI (+) reconstruction acquired by DECT may be helpful for the preoperative evaluation of breast cancer.

Content-Based Image Retrieval of Chest CT with Convolutional Neural Network for Diffuse Interstitial Lung Disease: Performance Assessment in Three Major Idiopathic Interstitial Pneumonias

  • Hye Jeon Hwang;Joon Beom Seo;Sang Min Lee;Eun Young Kim;Beomhee Park;Hyun-Jin Bae;Namkug Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.281-290
    • /
    • 2021
  • Objective: To assess the performance of content-based image retrieval (CBIR) of chest CT for diffuse interstitial lung disease (DILD). Materials and Methods: The database was comprised by 246 pairs of chest CTs (initial and follow-up CTs within two years) from 246 patients with usual interstitial pneumonia (UIP, n = 100), nonspecific interstitial pneumonia (NSIP, n = 101), and cryptogenic organic pneumonia (COP, n = 45). Sixty cases (30-UIP, 20-NSIP, and 10-COP) were selected as the queries. The CBIR retrieved five similar CTs as a query from the database by comparing six image patterns (honeycombing, reticular opacity, emphysema, ground-glass opacity, consolidation and normal lung) of DILD, which were automatically quantified and classified by a convolutional neural network. We assessed the rates of retrieving the same pairs of query CTs, and the number of CTs with the same disease class as query CTs in top 1-5 retrievals. Chest radiologists evaluated the similarity between retrieved CTs and queries using a 5-scale grading system (5-almost identical; 4-same disease; 3-likelihood of same disease is half; 2-likely different; and 1-different disease). Results: The rate of retrieving the same pairs of query CTs in top 1 retrieval was 61.7% (37/60) and in top 1-5 retrievals was 81.7% (49/60). The CBIR retrieved the same pairs of query CTs more in UIP compared to NSIP and COP (p = 0.008 and 0.002). On average, it retrieved 4.17 of five similar CTs from the same disease class. Radiologists rated 71.3% to 73.0% of the retrieved CTs with a similarity score of 4 or 5. Conclusion: The proposed CBIR system showed good performance for retrieving chest CTs showing similar patterns for DILD.

Imaging Predictors of Survival in Patients with Single Small Hepatocellular Carcinoma Treated with Transarterial Chemoembolization

  • Chan Park;Jin Hyoung Kim;Pyeong Hwa Kim;So Yeon Kim;Dong Il Gwon;Hee Ho Chu;Minho Park;Joonho Hur;Jin Young Kim;Dong Joon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.213-224
    • /
    • 2021
  • Objective: Clinical outcomes of patients who undergo transarterial chemoembolization (TACE) for single small hepatocellular carcinoma (HCC) are not consistent, and may differ based on certain imaging findings. This retrospective study was aimed at determining the efficacy of pre-TACE CT or MR imaging findings in predicting survival outcomes in patients with small HCC upon being treated with TACE. Besides, the study proposed to build a risk prediction model for these patients. Materials and Methods: Altogether, 750 patients with functionally good hepatic reserve who received TACE as the first-line treatment for single small HCC between 2004 and 2014 were included in the study. These patients were randomly assigned into training (n = 525) and validation (n = 225) sets. Results: According to the results of a multivariable Cox analysis, three pre-TACE imaging findings (tumor margin, tumor location, enhancement pattern) and two clinical factors (age, serum albumin level) were selected and scored to create predictive models for overall, local tumor progression (LTP)-free, and progression-free survival in the training set. The median overall survival time in the validation set were 137.5 months, 76.1 months, and 44.0 months for low-, intermediate-, and high-risk groups, respectively (p < 0.001). Time-dependent receiver operating characteristic curves of the predictive models for overall, LTP-free, and progression-free survival applied to the validation cohort showed acceptable areas under the curve values (0.734, 0.802, and 0.775 for overall survival; 0.738, 0.789, and 0.791 for LTP-free survival; and 0.671, 0.733, and 0.694 for progression-free survival at 3, 5, and 10 years, respectively). Conclusion: Pre-TACE CT or MR imaging findings could predict survival outcomes in patients with small HCC upon treatment with TACE. Our predictive models including three imaging predictors could be helpful in prognostication, identification, and selection of suitable candidates for TACE in patients with single small HCC.

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography (Stainless steel hand file과 Ni-Ti rotary file을 이용한 근관 형성시 근단부 근관 형태의 순차적 변화에 대한 평가)

  • Lee, Woo-Jin;Lee, Jeong-Ho;Chun, Kyung-A;Seo, Min-Seock;Yoo, Yeon-Jee;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Objectives: The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file) hand file, ProFile and LightSpeed using microcomputed tomography (MCT). Materials and Methods: Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1-, 2-, 3-, and 5- mm level from the apex. Data were statistically analyzed according to 'repeated nested design' and Mann-Whitney test (p = 0.05). Results: In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions: SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

A Case of Complete Remission after Concurrent Chemoradiotherapy for Esophageal Squamous cell Carcinoma with Solitary Bone Metastasis (고립성 골 전이를 동반한 식도편평세포암에서 동시 항암화학방사선 요법 후 완전관해를 보인 1례)

  • Woo Jin Lee;Hoon Jai Chun;Ye Ji Kim;Sun Young Kim;Min Ho Seo;Hyuk Soon Choi;Eun Sun Kim;Bora Keum;Yoon Tae Jeen;Hong Sik Lee;Soon Ho Um;Chang Duck Kim;Ho Sang Ryu
    • Journal of Digestive Cancer Research
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 2013
  • There is no established treatment for esophageal carcinoma with metastasis. For the metastatic esophageal squamous cell carcinoma, chemotherapy or best supportive care according to patient's performance status are accepted as an available treatment. We report a case of complete remission after concurrent chemoradiotherapy for esophageal squamous cell carcinoma with metastatic lesion in 5th thoracic vertebrae. A 57-year-old man with ongoing dysphagia and weight loss was admitted to our hospital. On the endoscopic and radiologic imaging evaluation,the patient was diagnosed as a squamous cell carcinoma of esophagus with solitary metastatic lesion in 5th thoracic vertebrae. The patient was treated with combination chemotherapy (5-fluorouracil (5-FU) and cisplatin) and concurrent radiotherapy for two months to relieve dysphagia. Because metastatic lesion in thoracic vertebrae was located near the primary esophageal tumor, the metastatic lesion could be included within the radiation field. After concurrent chemoradiotherapy, consecutive 4 cycles of chemotherapy had been carried out. Primary esophageal tumor with metastatic lymph nodes and metastatic lesion in 5th thoracic vertebrae disappeared on follow up computed tomography (CT) and positron emission tomography-CT (PET-CT). Follow up endoscopic biopsy revealed no remnant malignant cells at previous primary cancer lesion.

  • PDF

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF

The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion (골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구)

  • Kim, Moon-Hwan;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.389-403
    • /
    • 2008
  • In Angle's Class III malocclusion, which has higher incidence in Korean than Western, depressed midfacial profile with protruded lower lips and mandible may give rise to many functional, esthetic, psychological, social problems. Due to the different malocclusion incidence according to racial differences, many previous studies focused on the relationship between Class II malocclusion and nasal airway obstruction. Previous studies used lateral cephalography which has limitations of 2 dimensional image with projection error and identification error. Therefore, the purpose of this study was to analyze morphologic differences in the nasal airway between normal occlusion and Angle's Class III malocclusion patients using 3-dimensional facial computed tomography. Thirteen normal occlusion(7 men and 6 women) and sixteen skeletal Class III(7 men and 9 women) patients were selected and 3-dimensional facial computed tomography taking was performed. Comparison between two group in volume and sectional area of nasal airway were carried out. The results were followed. 1. In the comparison of absolute nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 2. In the comparison of relative nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 3. In the oropharyngeal space width on frontal and lateral view, the similar tendency was revealed between two groups. 4. In the lateral curvature of nasal airway, the similar tendency was revealed between two groups.

Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions (폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성)

  • Kang, Pil-Je;Kim, Yong-Hee;Park, Seung-Il;Kim, Dong-Kwan;Song, Jae-Woo;Do, Kyoung-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.624-629
    • /
    • 2009
  • Background: Making the histologic diagnosis of small pulmonary nodules and ground glass opacity (GGO) lesions is difficult. CT-guided percutaneous needle biopsies often fail to provide enough specimen for making the diagnosis. Video-assisted thoracoscopic surgery (VATS) can be inefficient for treating non-palpable lesions. Preoperative localization of small intrapulmonary lesions provides a more obvious target to facilitate performing intraoperative. resection. We evaluated the efficacy of CT-guided localization with using a hook wire and this was followed by VATS for making the histologic diagnosis of small intrapulmonary nodules and GGO lesions. Material and Method: Eighteen patients (13 males) were included in this study from August 2005 to March 2008. 18 intrapulmonary lesions underwent preoperative localization by using a CT-guided a hook wire system prior to performing VATS resection for intrapulmonary lesions and GGO lesions. The clinical data such as the accuracy of localization, the rate of conversion-to-thoracotomy, the operation time, the postoperative complications and the histology of the pulmonary lesion were retrospectively collected. Result: Eighteen VATS resections were performed in 18 patients. Preoperative CT-guided localization with a hook-wire was successful in all the patients. Dislodgement of a hook wire was observed in one case. There was no conversion to thoracotomy, The median diameter of lesions was 8 mm (range: $3{\sim}15\;mm$). The median depth of the lesions from the pleural surfaces was 5.5 mm (range: $1{\sim}30\;mm$). The median interval between preoperative CT-guided with a hook-wire and VATS was 34.5 min (range: ($10{\sim}226$ min). The median operative time was 43.5.min (range: $26{\sim}83$ min). In two patients, clinically insignificant pneumothorax developed after CT-guided localization with a hook-wire and there were no other complications. Histological examinations confirmed 8 primary lung cancers, 3 cases of metastases, 3 cases of inflammation, 2 intrapulmonary lymph nodes and 2 other benign lesions. Conclusion: CT-guided localization with a hook-wire followed by VATS for treating small intrapulmonary nodules and GGO lesions provided a low conversion thoracotomy rate, a short operation time and few localization-related or postoperative complications. This procedure was efficient to confirm intrapulmonary lesions and GGO lesions.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).