• 제목/요약/키워드: computed

검색결과 12,323건 처리시간 0.041초

EFFICIENT COMPUTATION OF THE ACCELERATION OF THE CONTACT POINT BETWEEN ROTATING SURFACES AND APPLICATION TO CAM-FOLLOWER MECHANISM

  • LEE K.
    • International Journal of Automotive Technology
    • /
    • 제7권1호
    • /
    • pp.115-120
    • /
    • 2006
  • On a rotating contact surface of arbitrary shape, the relative velocity of the contact point sliding between the surfaces is computed with the basic geometries of the rotating surfaces, and the acceleration of the contact point between the contact surfaces is computed by using the relative velocity of the contact point. Thus the equation for the acceleration constraint between the contact surfaces in muitibody dynamics is not coupled with the parameters such as the relative velocity of the contact point. In case of the kinematic analysis, the acceleration of the contact point on any specific instant may also be efficiently computed by the present technique because the whole displacement of a full cycle need not be interpolated. Employing a cam-follower mechanism as a verification model, the acceleration of the contact point computed by the present technique is compared with that computed by differentiating the displacement interpolated with a large number of nodal points.

전산화단층상을 이용한 측두하악관절의 삼차원 재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF TEMPOROMANDIBULAR JOINT USING COMPUTED TOMOGRAM)

  • 임숙영;고광준
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.335-344
    • /
    • 1993
  • The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joints were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint spaces were more clearly visualized on dissection images.

  • PDF

Cone-beam computed tomographic imaging of silent sinus syndrome: A case series and a literature review

  • Manila, Nisha G.;Arashlow, Mehrnaz Tahmasbi;Ehlers, Scott;Liang, Hui;Nair, Madhu K.
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.365-371
    • /
    • 2020
  • While silent sinus syndrome (SSS) is familiar to otolaryngologists and ophthalmologists, it is a rare clinical entity in dentistry and is likely to be underdiagnosed due to dentists' lack of awareness of this condition. SSS presents a diagnostic challenge to dentists, as patients typically have no history of trauma or sinusitis. The characteristic feature of SSS is a gradual retreat of the maxillary sinus walls, resulting in enophthalmos and hypoglobus. Multidetector (multislice) computed tomography is the imaging modality of choice for SSS and other paranasal sinus diseases. Cone-beam computed tomography promises to be an alternative low-dose imaging modality. This report describes 3 cases of SSS in adults, who had no identified clinical symptoms except diminutive and opacified maxillary sinuses, as well as the inward bowing of the sinus walls as noted on cone-beam computed tomographic imaging.

안와벽 재건술 시행 후 평가방법으로서 초음파의 효용성 (Effectiveness of the ultrasonography in the evaluation following orbit wall reconstruction)

  • 김창윤;양정열;천지선;문재원
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.428-431
    • /
    • 2009
  • Purpose: Blow out fracture resulting from facial trauma is of high frequency among facial bone fractures, and can cause severe complications. So, proper management and close observation after operation are needed. So far, Computed tomography has been the best choice in the evalution following orbit wall reconstruction. However, cost - effectiveness, accessibility to patients and hazard of radiation exposure of computed tomography require supplementary measure for the evaluation following orbit wall reconstruction. This study was performed to describe the effectiveness of ultrasonography in the evalution following orbit wall reconstruction. Methods: A retrospective study was performed on 40 patients who underwent orbit wall reconstruction from June, 2008 to July, 2008. The patients' ages ranged from 13 to 65 years (mean 27.5 years), and this group was compsoed of 27 male and 13 female patients. The follow up period ranged from 2 weeks to 28 weeks (mean 11weeks). Preoperatively, all fractures were diagnosed using computed tomography. Ultrasonography for all cases, and computed tomography for 2 cases were performed for evaluation following orbit wall reconstruction. Results: Reduction of herniated orbital soft tissue and orbit implant was identified by using ultrasonography in 38 cases out of 40 cases. In other cases which we could not identify the orbit implant, computed tomography was performed. Con clusion: Compared to computed tomography, ultrasonography is simple, inexpensive and convenient method. Ultrasonography can be used as supplementary measure to computed tomography in the evaluation following orbit wall reconstruction for elective patients.

컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구 (A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique)

  • 성열훈;임재동
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).

Correlation between Transient Elastography (Fibroscan®) and Ultrasonographic and Computed Tomographic Grading in Pediatric Nonalcoholic Steatohepatitis

  • Lee, Ji Eun;Ko, Kyung Ok;Lim, Jae Woo;Cheon, Eun Jung;Song, Young Hwa;Yoon, Jung Min
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제25권3호
    • /
    • pp.240-250
    • /
    • 2022
  • Purpose: This study aimed to examine the advantages and usefulness of transient elastography (Fibroscan®) in diagnosing non-alcoholic steatohepatitis in children and adolescents compared to those of abdominal computed tomography and liver ultrasonography. Methods: Forty-six children and adolescent participants aged between 6 and 16 years who underwent transient elastography (Fibroscan®) as well as liver ultrasonography or abdominal computed tomography were included. Thirty-nine participants underwent liver ultrasonography and 11 underwent computed tomography. The physical measurements, blood test results, presence of metabolic syndrome, and the degree of liver steatosis and liver fibrosis were analyzed, and their correlations with transient elastography (Fibroscan®), abdominal computed tomography, and liver ultrasonography, as well as the correlations between examinations, were analyzed. Results: Thirty-six participants (78.3%) were boys, and the mean age was 12.29±2.57 years, with a mean body mass index of 27.88±4.28. In the 46 participants, the mean values for aspartate aminotransferase, alanine aminotransferase, and total bilirubin were 89.87±118.69 IU/L, 138.54±141.79 IU/L, and 0.77±0.61 mg/dL, respectively. Although transient elastography (Fibroscan®) and abdominal computed tomography grading had a statistically significant positive correlation with aspartate aminotransferase and alanine aminotransferase values, the correlations between the results of grading performed by transient elastography (Fibroscan®), abdominal computed tomography, and liver ultrasonography were not statistically. Conclusion: We confirmed that each examination was correlated with the results of some blood tests, suggesting the usefulness and possibility of diagnosis and treatment of steatohepatitis mediated by transient elastography (Fibroscan®) in the department of pediatrics.

악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용 (Application of Simulated Three Dimensional CT Image in Orthognathic Surgery)

  • 김형돈;유선국;이경상;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

하악골 전산화단층사진촬영시 기준선에 관한 연구 (Reference line for computed tomogram of the mandible)

  • 유충현;김재덕
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.153-157
    • /
    • 2002
  • Purpose : This study was performed to determine the proper reference line for taking axial computed tomograms from which the good cross-sectional views can be reformatted by multiplanar reconstruction. Methods : Three dry mandibles with implanted gutta percha cones in the extracted socket were scanned axially according to 6 reference lines of 2 mandibular positions with computed tomogram Hitachi W550. The accuracy of measurements of the lengths of implanted gutta perch a cones in the each cross-sectional view reformatted from axial computed tomogram by multiplanar reconstruction was evaluated. Results: The difference between the measurements and the real length of implant was smallest in the bucco-lingual views reformatted from the axial views scanned according to the reference line of group V-a. The smaller the angle difference between reference line and occlusal line was, the smaller the difference between the measurements in the bucco-lingual views reformatted from axial views and the real length of implant. The majority of measured widths of implants in the bucco-lingually reformatted views were larger than the actual values. Conclusions : When the mandible is inclined within the limitation of gantry angle and scanned with the reference line coincident with occlusal plane, the bucco-lingual view can be reformatted without deformation of images from the axially scanned images.

  • PDF

흉부 전산화 단층촬영을 이용한 혈흉의 정량분석 (Quantitative analysis of hemothorax by computed tomography)

  • 강청희
    • Journal of Chest Surgery
    • /
    • 제28권3호
    • /
    • pp.228-232
    • /
    • 1995
  • Computed tomography[CT is an effective technique for the evaluation of the thorax following blunt trauma. To evaluate multiply injured 30 patients who were diagnosed as hemothorax in emergency room, computed tomography of thorax was done. The thickness of slice was one centimeter and the entire pleural cavity from the apex to the costophrenic angle was included in the evaluation. Integration and addition of the hemothorax area for each CT slice was made and amount of blood in the pleural cavity was estimated. The slice which showed largest area of hemothorax was selected and the height and width of the hemothorax area were measured. The number of slices which showed radiographic evidence of hemothorax was counted. Regression analysis was done and measured amount of hemothorax, the height and width of the hemothorax area for each slice and number of slices were put as variables. And following equation was derived. V=108.3A-0.8B-7.4C+84.7 [R2=0.74 [ V: amount of hemothorax, A: height, B: width, C: number of slices Total amount of blood from thoracic drainage was compared to the measured amount by computed tomography and the relation between the two values was statistically significant.[p=0.001 In conclusion, quantitative estimation of size of hemothorax was possible by the above equation and the process was very helpful for determination policy of treatment of individual patient.

  • PDF