• 제목/요약/키워드: computed

검색결과 12,323건 처리시간 0.04초

Honeycomb Seal의 유동 특성 해석 (A Numerical Study on Flow Characteristics of a Honeycomb seal)

  • 홍은표;허남건
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.153-157
    • /
    • 2000
  • Honeycomb seals are used widely in gas turbines due to their good sealing performance and rotor-dynamic stability. Three-Dimensional complex flows in a honeycomb seal were analyzed in the present study. Friction factors were computed to predict the performance of a honeycomb seal based on pressure drop results for various honeycomb cell geometry and Reynolds numbers. Computed results for friction factor are compared to the available experimental data. Unlike in the experiment, where 'Friction-Factor Jump' phenomena are reported for some cases, computed results show no jump phenomena. The friction factors, however, are in good agreement with the experiment in no-jump cases.

  • PDF

임플란트 매식부의 고경 평가 : 파노라마 촬영법과 나선형 전산화 단층촬영법의 계측 비교 (Bone height measurements of implant sites : Comparison of panoramic radiography and spiral computed tomography)

  • 조봉혜
    • Imaging Science in Dentistry
    • /
    • 제32권2호
    • /
    • pp.61-66
    • /
    • 2002
  • Purpose: To compare the bone height of implant sites measured using panoramic radiography and spiral CT. Materials and Methods : The available bone height was determined for 263 maxillary and mandibular implant sites in 59 patients. Distortion was calculated using the metal bar for the panoramic radiographs. Results: Significant differences in mean bone height between the two imaging modalities were found in maxillary and mandibular anterior regions (p<0.05). The mean difference in bone height recorded by the two techniques was smallest in the maxillary and mandibular molar areas (0.8 mm), and greatest in the mandibular anterior region (1.3 mm). With the exception of the mandibular anterior region, ninety percent of all the sites showed measurement differences within 2 mm. Conclusion: A safety margin of 2 to 3 mm is called for when utilizing panoramic radiography, otherwise additional imaging modality such as computed tomography is necessary to obtain accurate measurements.

  • PDF

Stafne bone cavity and cone-beam computed tomography: a report of two cases

  • Venkatesh, Elluru
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권3호
    • /
    • pp.145-148
    • /
    • 2015
  • In 1942 Stafne reported 35 asymptomatic, radiolucent cavities that were unilaterally located in the posterior region of the mandible between the mandibular angle and the third molar, and below the mandibular canal. The term Stafne bone cavity (SBC) is now used for such asymptomatic lingual bone depressions of the lower jaw. Since then there have been many reports of SBCs but very fews tudies have used cone-beam computed tomography (CBCT) for their diagnosis. The aim of this paper is to describe the clinical and radiological characteristics of two cases of SBCs and the importance of limited CBCT in confirming the diagnosis.

Accessory mental foramen: A rare anatomical variation detected by cone-beam computed tomography

  • Torres, Marianna Guanaes Gomes;Valverde, Ludmila De Faro;Vidal, Manuela Torres Andion;Crusoe-Rebello, Ieda Margarida
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.61-65
    • /
    • 2015
  • The mental foramen is a bilateral opening in the vestibular portion of the mandible through which nerve endings, such as the mental nerve, emerge. In general, the mental foramen is located between the lower premolars. This region is a common area for the placement of dental implants. It is very important to identify anatomical variations in presurgical imaging exams since damage to neurovascular bundles may have a direct influence on treatment success. In the hemimandible, the mental foramen normally appears as a single structure, but there are some rare reports on the presence and number of anatomical variations; these variations may include accessory foramina. The present report describes the presence of accessory mental foramina in the right mandible, as detected by cone-beam computed tomography before dental implant placement.

Removal of a broken needle using three-dimensional computed tomography: a case report

  • Kim, Jin-Ha;Moon, Seong-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권5호
    • /
    • pp.251-253
    • /
    • 2013
  • Inferior alveolar nerve block obtained maximum anesthetic effect using a small dose of local anesthetic agent, which also has low a complication incidence. Complications of an inferior alveolar nerve block include direct nerve damage, bleeding, trismus, temporary facial nerve palsy, and etc. Among them, the major iatrogenic complication is dental needle fracture. A fragment that disappears into the soft tissue would be hard to remove, giving rise to a legal problem. A 31-year-old woman was referred for the removal of a broken needle, following an inferior alveolar nerve block. Management involved the removal of the needle under local anesthesia with pre- and peri-operative computed tomography scans.

Circular-to-Rectangular Transition Duct 에서의 3차원 유동장에 관한 연구 (Three-Dimensional Numerical Simulation on a Circular-to-Rectangular Transition Duct)

  • 조수용;손호재
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 추계 학술대회논문집
    • /
    • pp.55-61
    • /
    • 1998
  • The purpose of this study is to compare the predictive behaviors of the extended $k-{\varepsilon}$ turbulence model and the standard $k-{\varepsilon}$ turbulence model. Grid dependency is tested with the H-type grid and the O-type grid. Computations have been performed for a circular-to-rectangular transition duct. Numerical results for several sections along the streamwise have been obtained to compare with experimental results. The Reynolds number is 390,000 based on the bulk velocity at the inlet. The computed axial velocity contours, transverse velocity profiles, static pressure contours, peripheral skin friction coefficient, and peripheral wall static pressure distributions have been compared with experimental results. The computed results obtained with the extended $k-{\varepsilon}$ turbulence model show better agreement with experimental results than those obtained with the standard $k-{\varepsilon}$ turbulence model. Comparing to the computed results obtained with the H-type grid and O-type grid, those with H-type grid agree well with experimental results.

  • PDF

Inverse Kinematic and Dynamic Analyses of 6-DOF PUS Type parallel Manipulators

  • Kim, Jong-Phil;Jeha Ryu
    • Journal of Mechanical Science and Technology
    • /
    • 제16권1호
    • /
    • pp.13-23
    • /
    • 2002
  • This paper presents inverse kinematic and dynamic analyses of HexaSlide type six degree-of-freedom parallel manipulators. The HexaSlide type parallel manipulators (HSM) can be characterized as an architecture with constant link lengths that are attached to moving sliders on the ground and to a mobile platform. In the inverse kinematic analyses, the slider and link motion (position, velocity, and acceleration) is computed given the desired mobile platform motion. Based on the inverse kinematic analysis, in order to compute the required actuator forces given the desired platform motion, inverse dynamic equations of motion of a parallel manipulator is derived by the Newton-Euler approach. In this derivation, the joint friction as well as all link inertia are included. Relative importance of the link inertia and joint frictions on the computed torque is investigated by computer simulations. It is expected that the inverse kinematic and dynamic equations can be used in the computed torque control and model-based adaptive control strategies.

도로교통소음 음향파워레벨 산정과 응용에 관한 연구 (A Study on the Computation and Application of Sound Power Level for Road Traffic Noise)

  • 김득성;오진우;홍세화;이기정;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.527-534
    • /
    • 2004
  • This study is a paper relating to between road traffic noise(RTN) and sound power level(PWL). At present to prediction of RTN is used to many experimental models and prediction methods. RTN is computed PWL using existing experimental models and prediction methods. Then, computed PWL is compared with it of measurement value, in them, it is selected model most similar to measurement value. And then, this results will watch for make Noise Map, as application field applied to computed results.

  • PDF

기침으로 초래된 단순 늑골골절 1례 (Case Report of a Simple Rib Fracture Caused by Coughing)

  • 최우익
    • Journal of Trauma and Injury
    • /
    • 제27권1호
    • /
    • pp.9-12
    • /
    • 2014
  • Violent or severe persistent coughing is rarely associated with rib fracture. We report a rare case of a cough-induced rib fracture in a patient without any traumatic history or any other underlying disease. A 32-year-old female presented to the emergency department complaining of having had right-sided pleuritic chest pain for 5 days. She had a background of an 8-week coughing illness. A posteroanterior view of the chest radiograph showed no definite fractured line. Chest computed tomography revealed a subtle break cortical line of the 7th rib in the right-sided chest wall. Early identification of a cough-induced fracture of the rib by using computed tomography may avoid unnecessary further work-ups including laboratory examination and may lead to appropriate discharge instructions including rest and reassurance. The clinical presentations and radiologic findings of rib fractures caused by coughing are presented along with a review of the literature.

An Adaptive Image Quality Assessment Algorithm

  • Sankar, Ravi;Ivkovic, Goran
    • International journal of advanced smart convergence
    • /
    • 제1권1호
    • /
    • pp.6-13
    • /
    • 2012
  • An improved algorithm for image quality assessment is presented. First a simple model of human visual system, consisting of a nonlinear function and a 2-D filter, processes the input images. This filter has one user-defined parameter, whose value depends on the reference image. This way the algorithm can adapt to different scenarios. In the next step the average value of locally computed correlation coefficients between the two processed images is found. This criterion is closely related to the way in which human observer assesses image quality. Finally, image quality measure is computed as the average value of locally computed correlation coefficients, adjusted by the average correlation coefficient between the reference and error images. By this approach the proposed measure differentiates between the random and signal dependant distortions, which have different effects on human observer. Performance of the proposed quality measure is illustrated by examples involving images with different types of degradation.