• Title/Summary/Keyword: compressive strength loss

Search Result 301, Processing Time 0.021 seconds

Development of Shrinkage Reducing Agent for 3D Printing Concrete (3D 프린팅 콘크리트용 수축저감제 개발)

  • Lee, Dong-gyu;Yoo, Byung-Hyun;Son, Ho-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.37-43
    • /
    • 2019
  • Since 3D printed concrete can be constructed without formwork, it is easy to construct an atypical structure, and the construction time and labor cost can be reduced. However, since the construction is exposed to the outside, shrinkage cracking due to moisture loss inside and outside the concrete occurs. Therefore, in order to improve the durability of the 3D printed concrete, a shrinkage reduction plan of the 3D printed concrete is required. In this study, glycol-based and alcohol-based shrinkage reducing agents were fabricated and evaluated for their performance. The shrinkage reducing agent samples showing excellent performance were selected and applied to 3D printed concrete. As a result, the compressive strength was increased by more than 10% and the shrinkage was reduced by more than 36% when using a shrinkage reducing agent. It is expected that the production of high quality 3D printed concrete will be possible because it is possible to increase the compressive strength and reduce the amount of dry shrinkage by applying a shrinkage reducing agent for 3D printed concrete.

Study on the Thermal Characteristics of Concrete Using Micro Form Admixture (마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구)

  • Park, Young Shin;Kim, Jung Ho;Jeon, Hyun Kyu;Seo, Chee Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. So, various actions to reduce greenhouse gas exhaustion and energy consumption have been prepared by world developed countries. Our government has also been trying to seek energy control methods for houses and buildings by proclaiming political polices on low-carbon green growth and construction and performance standards for environment-friendly housing. The energy consumption by buildings approximately reaches 25% of total korea energy consumption, and the increasing rate of energy consumption by buildings is stiffer than the rate by the other industries. The greatest part in the buildings of the energy consumption is building facade. While lots of research projects for reducing energy consumption of the facade have been conducted, but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research presents here a study to improve the insulation property of structural concrete formed by micro form admixture (MFA) with experimentally reviewing the physical, mechanical and thermal characteristics of the concrete. As the results of this experiment, in the case of concrete mixed with MFA, slump loss has been improved. As the mixing ratio of MFA increases, the compressive strength is decreased and thermal conductivity is increased. Also it was found that water-cement ratio increases, the compressive strength is decreased and thermal conductivity is increased. but, there was not big influence by the change of fine aggregate ratio.

A Study on the Residual Mechanical Properties of Fiber Reinforced Concrete with High Temperature and Load (고온 및 하중에 따른 섬유보강 콘크리트의 잔존 역학적 특성에 관한 연구)

  • Kim, Young-Sun;Lee, Tae-Gyu;Nam, Jeong-Soo;Park, Gyu-Yeon;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.321-330
    • /
    • 2011
  • Recently, the effects of high temperature and fiber content on the residual mechnical properties of high-strength concrete were experimentally investigated. In this paper, residual mechanical properties of concrete with water to cement (w/c) ratios of 0.55, 0.42 and 0.35 exposed to high temperature are compared with those obtained in fiber reinforced concrete with similar characteristics ranging from 0.05% to 0.20% polypropylene (PP) fiber volume percentage. Also, factors including pre-load levels of 20% and 40% of the maximum load at room temperature are considered. Outbreak time, thermal strain, length change, and mass loss were tested to determine compressive strength, modulus of elasticity, and energy absorption capacity. From the results, in order to prevent the explosive spalling of 50 MPa grade concretes exposed to high temperature, more than 0.05 vol. % of PP fibers is needed. Also, the cross-sectional area of PP fiber can influence the residual mechanical properties and spalling tendency of fiber reinforced concrete exposed to high temperature. Especially, the external loading increases not only the residual mechanical properties of concrete but also the risk of spalling and brittle failure tendency.

Examination of the Characteristics of Mortar Mixed with Boron Compounds Presenting Various Levels of Alkalinity (다양한 알칼리도를 가진 붕소화합물이 혼입된 모르타르의 특성 검토)

  • Lee, Binna;Lee, Jong-Suk;Min, Jiyoung;Lee, Jang Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.85-92
    • /
    • 2017
  • This study examines the characteristics of mortar mixed with various boron compounds. The adapted boron compounds, classified into acid, slightly alkaline and strongly alkaline with respect to the value of the pH are acid-based boron (AA), low-alkaline-based boron (AB), and high-alkaline-based boron (HB). The pH test, setting test and compressive strength test are performed to evaluate the physical and chemical properties of mortar, and SEM imaging is conducted to analyze the microstructure of mortar. The measured pH shows that the specimens mixed with boron compounds have lower pH than the basic mortar without boron and that loss of pH occurs according to time. The setting test reveals that the initial and final setting times of the specimens mixed with boron compounds occur later than the basic mortar, which disagrees slightly with the previous literature stating that the setting time can be shortened according to the alkalinity. From the compressive strength test and SEM imaging results, it is recommended to determine the optimal content of boron considering type and composition of the boron compounds.

Characteristics of the 80MPa High Strength Concrete according to the Hot Weather Outside Temperature conditions (서중 외기온도 조건에 따른 80 MPa 고강도콘크리트의 특성)

  • Jung, Yong-Wook;Lee, Seung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.688-696
    • /
    • 2016
  • This paper evaluates the effect of hot weather conditions on the fresh concrete characteristics of 80-MPa high-strength concrete. The slump flow, packing ability, setting time, hydration heat, and compressive strength were evaluated under exterior temperatures of $20^{\circ}C$, $30^{\circ}C$, and $40^{\circ}C$. The slump flow, arrival speed of 500 mm, and their changes with the elapsed time were found to bring the occurrence of rapid slump loss forward by about 30 minutes when increasing the temperature by $10^{\circ}C$ from $20^{\circ}C$. The initial and final setting times of the concrete at $20^{\circ}C$ were 7 hours and 12 hours, which were reduced by 1 hour and 3 hours at $30^{\circ}C$ and by 2 hours and 5 hours at $40^{\circ}C$, respectively. The hydration heat characteristics at $20^{\circ}C$ and $30^{\circ}C$ were similar in terms of the highest temperature of the concrete casting depth and the time when the maximum temperature occurred. However, at $40^{\circ}C$, the maximum temperature occurred about 4 hours earlier, and the highest temperature per the concrete casting depth increased by about $12^{\circ}C$. Therefore, it is concluded that the characteristics can vary according to the exterior temperature. Thus, quality assurance should consider workability, temperature cracks due to hydration heat, the properties of strength development, and other characteristics.

Effect of Refinement of Fly Ash on Engineering Properties of Cement Mortar (플라이애시의 정제가 모르타르의 공학적 특성에 미치는 영향)

  • Han, Min-Cheol;Moon, Byeong-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.275-281
    • /
    • 2017
  • This study is to investigate experimentally the effect of refining of fly ash (FA) on the engineering properties of the cement mortar. Five different FAs are used including raw fly ash, refined fly ash, reject ash and their two different combinations. The cement mortars are fabricated with 1:1(binder to fine aggregate), 1 : 3 and 1 : 5 respectively, which are replaced 30% of FA by cement. Test results, indicated that, the flow of Ra showed lower flowability than Rf at all mixing ratios. Also in the case of Rj, it was expected to show low fluidity, but it showed flowability equal to or higher than Rf. Air contents are all formulations except Rf and Rj did not satisfy the target range. Using Ra, the refining process shows an air amount about 41% lower than Rf, in the case of Rj, it showed about 19% higher air content than Rf due to porous foreign matters inside the mortar. Compressive strength was in the early days 3 and 7, the strength was lower than that of Plain's OPC, after 28 days Rf exerts higher strength than other FAs, it was confirmed that higher strength than OPC can be secured at a mixing ratio of 1: 1 and 1: 3. For frost resistance, the use of unrefined FA resulted in decrease of frost resistance sharply due to loss of air content by the use of unrefined FA. Therefore, it is considered that the use of high quality FA through refining process will contribute positively to the economical formulation of concrete and the stability of the structure.

Effect of Fiber Types on Fundamental Properties of Pavement Concrete (섬유 종류가 도로포장용 콘크리트의 기초적 특성에 미치는 영향)

  • Han, Cheon-Goo;Park, Jong-Sup;Jung, Woo-Tai;Jeon, Kyu-Nam
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.473-479
    • /
    • 2010
  • The objective of the paper is to experimentally investigate the effect of commercially avaliable fiber types such as polypropylene (PP), nylon (NY), polyvinyl alcohol (PVA) and cellulose (CL) on the engineering properties of concrete for pavement application. The results, showed the fluidity tends to decrease with fibers addition compared to that of plain concrete. As for the effect of fiber types on fluidity loss, use of NY appear to give the most favorable results among all of the fiber types investigated in this study while the effect of the fibers on air content was negligible. For the properties of hardened concrete, compressive and flexural strengths increased with fibers compared to plain concrete. The contribution of NY fibers to strength was the highest followed in the order by NY, PVA, PP, and CL. However, in the case of the splitting tensile strength, its values were increased with NY and PP only. For porosity based on MIP(mercury intrusion penetration) method, the number of around 1 was observed when NY was mixed resulting in increased cumulated amounts of porosity compared with that of plain mix. Thus, based on the consideration of fluidity and strength it was found that the addition of NY fiber showed the optimal results under the conditions applied in this study.

The study on the manufacturing intermediary materials for the carbon nanofiber reinforced Cu matrix noncomposite (일방향 탄소나노섬유 강화 Cu 기지 나노복합재료용 중간재 제조에 관한 연구)

  • 백영민;이상관;엄문광
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.46-49
    • /
    • 2003
  • Cu have been widely used as signal transmission materials for electrical electronic components owing to its high electrical conductivity. However, it's size have been limited to small ones due to its poor mechanical properties, Until now, strengthening of the copper at toy was obtained either by the solid solution and precipitation hardening by adding alloy elements or the work hardening by deformation process. Adding the at toy elements lead to reduction of electrical conductivity. In this aspect, if carbon nanofiber is used as reinforcement which have outstanding mechanical strength and electric conductivity, it is possible to develope Cu matrix nanocomposite having almost no loss of electric conductivity. It is expected to be innovative in electric conduct ing material market. The unidirectional alignment of carbon nanofiber is the most challenging task developing the copper matrix composites of high strength and electric conductivity In this study, the unidirectional alignment of carbon nanofibers which is used reinforced material are controlled by drawing process in order to manufacture the intermediary materials for the carbon nanofiber reinforced Cu matrix nanocomposite and align mechanism as well as optimized drawing process parameters are verified via experiments and numerical analysis. The materials used in this study were pure copper and the nanofibers of 150nm in diameter and of $10~20\mu\textrm{m}$ In length. The materials have been tested and the tensile strength was 75MPa with the elongation of 44% for the copper it is assumed that carbon nanofiber behave like porous elasto-plastic materials. Compaction test was conducted to obtain constitutive properties of carbon nanofiber. Optimal parameter for drawing process was obtained by experiments and numerical analysis considering the various drawing angles, reduction areas, friction coefficient, etc Lower reduction areas provides the less rupture of cu tube is not iced during the drawing process. Optimal die angle was between 5 degree and 12 degree. Relative density of carbon nanofiber embedded in the copper tube is higher as drawing diameter decrease and compressive residual stress is occurred in the copper tube. Carbon nanofibers are moved to the reverse drawing direct ion via shear force caused by deformation of the copper tube and alined to the drawing direction.

  • PDF

Effects of Radiation on Thermal and Mechanical Properties of Modified Epoxy Resin and Hydrogenated Bisphenol-A Type Epoxy Resin Based Shielding Materials (개질 에폭시수지 및 수소 첨가된 비스페놀-A형 에폭시수지계 차폐재의 열적 및 역학적 성질에 미치는 방사선 영향)

  • Cho, Soo-Haeng;Hong, Sun-Seok;Kim, Ik-Soo;Do, Jae-Bum;Ro, Seung-Gy
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.524-532
    • /
    • 1997
  • ffects of radiation on the thermal and mechanical properties of modified epoxy resin and hydrogenated bisphenol-A type epoxy resin based neutron shielding materials to be used for radioactive material shipping and storage casks have been investigated. The onset temperatures of the shielding materials of KNS(Kaeri Neutron Shield)-201 and KNS-302 increased with the radiation dose, but those of KNS-202 and KNS-301 decreased at radiation dose above 0.5 MGy. In addition, the radiation dose rarely affected the change of weight of shielding materials with the variation in temperature. At radiation dose up to 0.1 MGy, thermal conductivities of shielding materials were not affected. The thermal expansion coefficients of the shielding materials of KNS-301 and 302 were affected to a less extent than those of KNS-201 and 202 by radiation. At radiation dose up to 0.1 MGy, the tensile strength, compressive strength and flexural strength of the shielding materials of KNS-202 and KNS-301 and 302 increased with the radiation dose. In contrast, those of KNS-201 decreased with an increase in the radiation dose. In addition, the amount of radiation dose on the shielding materials did not result in a measurable loss of specific gravity, weight and hydrogen content.

  • PDF

A Study on the Characteristics of High-Tension Bolted Joints' Behavior due to Surface Condition (표면상태에 따른 고장력볼트 마찰이음부의 거동특성에 관한 연구)

  • Cho, Sun Kyu;Hong, Sung Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.421-430
    • /
    • 1997
  • In this study, the static and the fatigue tests were performed with high tension bolted joints, of which the surfaces were spread with inorganic zinc-primer after shot-blast, and milling surface, and steel-natural surface, difference of friction surface condition were examined by comparing the esults of tests. From the result of synthetical investigation of this study. it is proper that using the torque management method in order to introduce design axial force to blots, and the provision of specifications that initial axial forces must be 110% of design axial forces is proper. Decreasing ratio of axial forces to initial force is proportional to common lorgarithms of time progress, it converge constant value after 20 hours, and decreasing ratio is little related to the roughness of friction surface. Sliding coefficient of milling, spreading inorganic zinc-primer, just producting is great in order and sliding forces are dependent on the applied axial forces, but if the applied axial forces are great, sliding coefficient become small by a loss of roughness. So it is confirmed that relation between the applied axial forces and the sliding forces are not proportional linearly. From the result of estimation on fatigue strength, all specimens satisfy the specifications with B-grade and milling surface is lower than the others about 14% in fatigue strength because in milling surface lose the function of friction-types joints at lower number of cycles. From the result of eximination for the distribution area of compressive force, friction area near to inside bolt is wider in the direction of stress than near to outside. It is guessed that this situation occurs because outside bolts firstly change from the friction connection to the bearing connection.

  • PDF