• Title/Summary/Keyword: compression error

Search Result 416, Processing Time 0.024 seconds

Active Video Watermarking Technique for Infectious Information Hiding System (전염성 정보은닉 시스템을 위한 능동형 비디오 워터마킹 기법)

  • Jang, Bong-Joo;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.8
    • /
    • pp.1017-1030
    • /
    • 2012
  • Most watermarking schemes for video contents protection have been studied to increase watermark's robustness and invisibility against such compressions and many kinds of signal processing after embedding copyright information to the original contents. This paper proposes an active watermarking that infect watermark to contents in the video decoding process using embedded infectious watermark and control signals from a video encoder side. To achieve this algorithm, we design a kernel based watermarking in video encoder side that is possible to recover the original contents and watermark in watermark detection procedure perfectly. And then, by reversible de-watermarking in video decoder side, we design the active watermark infection method using detected watermark and control signal. This means that our system can provide secure re-distributions of video contents without any quality degration and watermark bit error against transcoding or re-encoding processing. By experimental results, we confirmed that the embedded watermark was infected by video contents and codec perfectly without any declines of compression ratio and video quality.

On the Finite-world-length Effects in fast DCT Algorithms (고속DCT변환 방식의 정수형 연산에 관한 연구)

  • 전준현;고종석;김성대;김재균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.4
    • /
    • pp.309-324
    • /
    • 1987
  • In recent years has been an increasing interest with respect to using the discrete cosine transform(DCT) of which performance is found close to that of the Karhumen-Loeve transform, known to be optimal in the area of digital image processing for tha purpose of the image data compression. Among most of reported algorithms aimed at lowering the coputation complexity. Chen's algorithm is is found to be most popular, Recently, Lee proposed a now algorithm of which the computational complexity is lower than that of Chen's. but its performance is significantly degraded by FWL(Finite-Word-Lenght) effects as a result of employinga a fixed-poing arithmetic. In this paper performance evaluation of these two algorithms and error analysis of FWL effect are described. Also a scaling technique which we call Up & Down-scaling is proposed to allevaiate a performance degradation due to fixed-point arithmetic. When the 16x16point 2DCT is applied on image data and a 16-bit fixed-point arithmetic is employed, both the analysis and simulation show that is colse to that of Chen's.

  • PDF

The Redundancy Reduction Using Fuzzy C-means Clustering and Cosine Similarity on a Very Large Gas Sensor Array for Mimicking Biological Olfaction (생물학적 후각 시스템을 모방한 대규모 가스 센서 어레이에서 코사인 유사도와 퍼지 클러스터링을 이용한 중복도 제거 방법)

  • Kim, Jeong-Do;Kim, Jung-Ju;Park, Sung-Dae;Byun, Hyung-Gi;Persaud, K.C.;Lim, Seung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.59-67
    • /
    • 2012
  • It was reported that the latest sensor technology allow an 65536 conductive polymer sensor array to be made with broad but overlapping selectivity to different families of chemicals emulating the characteristics found in biological olfaction. However, the supernumerary redundancy always accompanies great error and risk as well as an inordinate amount of computation time and local minima in signal processing, e.g. neural networks. In this paper, we propose a new method to reduce the number of sensor for analysis by reducing redundancy between sensors and by removing unstable sensors using the cosine similarity method and to decide on representative sensor using FCM(Fuzzy C-Means) algorithm. The representative sensors can be just used in analyzing. And, we introduce DWT(Discrete Wavelet Transform) for data compression in the time domain as preprocessing. Throughout experimental trials, we have done a comparative analysis between gas sensor data with and without reduced redundancy. The possibility and superiority of the proposed methods are confirmed through experiments.

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Cardiac Decompressing Effect by Delayed Sternal Closure Following Open Heart Surgery in Children (소아에서 개심술후 정중흉골절개의 지연흉골폐쇄에 의한 심장압박 방지효과)

  • 김경환;서경필
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1167-1174
    • /
    • 1997
  • We retrospectively reviewed a series of 20 patients treated with delayed sternal closure during a 5-year period from 1991 to 1996. Of the 2675 patients with cardiovascular su gery 20 underwent this procedure. Male and female ratio was 11:9, mean age was 6.4 months(range 7 days to 5 years). The indications included unstable hemodynamic profiles after open heart surgery due to myocardial edema and poor lung compliance(15), necessity of mechanical ventricular assist device due to weaning failure(3), and hypoxia after PAB(2). Sternum was closed at a mean interval of 102(range 4 to 213) hours after operation. During delayed sternal closure, central venous pressure was elevated(p<0.05). Mediastinitis and other wound problems did not occur. Sepsis developed in 2 patients and microorganism was confirmed in one of the two patients. Five patients died(mortality 25%). And two of 15 discharged patients died during follow-up period. Cumulative survival rate was 65.0% at 12 months and also 65.0% at 24 months.(Standard error was 10.7%) Delayed sternal closure Is considered to be a good method to decompress the hemodynamically compromised heart. Without that, it is not f asible to come off bypass or to decompress the heart. Of course. careful selection of the indication is imperative.

  • PDF

Effects of Heating Conditions in the Straightening of Sheet Metal Distortion (박판재 변형의 가열교정에서 가열면적의 영향)

  • Park, Jun-Hyoung;Kim, Jae-Woong;Kim, Ki-Chul;Jun, Joong-Hwan
    • Journal of Welding and Joining
    • /
    • v.26 no.4
    • /
    • pp.79-84
    • /
    • 2008
  • Use of sheet metal structure is increased in various fields such as automobile, aerospace and communication equipment industry. When this structure is welded, welding distortion is generated due to the non-uniformity of temperature distribution. Recently welding distortion becomes a matter of great importance in the structure manufacture industry because it deteriorates the product's quality by bringing about shape error. Accordingly many studies for solving the problems by controlling the welding distortion are being performed. However, it is difficult to remove all kinds of distortion by welding process, though various kinds of methods for reducing distortion are applied to production. Consequently, straightening process is operated if the high precision quality is requested after welding. The local heating method induces compression plastic deformation by thermal expansion in the heating stage and then leaves constriction of length direction in the cooling stage. Accordingly, in the case of sheet metal structure, straightening effect is expected by heating for the part of distortion. This study includes numerical analysis of straightening effect by the local heating method in distortion comes from production of welded sheet metal structure. Particularly straightening effect followed by dimensions of heating area is analyzed according to the numerical analysis. The numerical analysis is performed by constructing 3-dimensional finite element model for 0.4mm stainless steel-sheet metal. Results of this study confirm that straightening effect changes as heating area increases and the optimum value of heating area that proves the maximum straightening effect exists.

Optimization Study on the Formulation of Roxithromycin Dispersible Tablet Using Experimental Design

  • Weon, Kwon-Yeon;Lee, Kyung-Tae;Sunseo, Sung-Hoon
    • Archives of Pharmacal Research
    • /
    • v.23 no.5
    • /
    • pp.507-512
    • /
    • 2000
  • This study set out to improve the physical and pharmaceutical characteristics of the present formulation using an appropriate experimental design. The work described here concerns the formulation of the dispersible tablet applying direct compression method containing roxithromycin in the form of coated granules. In this study $2^3$ factorial design was used as screening test model and Central Composite Design (CCC) associated with response surface methodology was used as optimization study model to develop and to optimize the proper formulation of roxithromycin dispersible tablet. The three independent variables investigated were functional excipients like binder (X1), disintegrant (X2) and lubricant (X3). The effects of these variables were investigated on the following responses: hardness (Y1), friability (Y2) and disintegration time (Y3) of tablet. Three replicates at the center levels of the each design were used to independently calculate the experimental error and to detect any curvature in the response surface. This enabled the best formulations to be selected objectively. The effect order of each term to all response variable was X3> X2> Xl> X1*X2> X2*X2> X2*X3> X3*X3> Xl*X3> Xl*Xl and model equations on each response variables were generated. Optimized compositions of formula were accordingly computed using those model equations and confirmed by following demonstration study. As a result, this study has demonstrated the efficiency and effectiveness of using a systematic formulation optimization process to develop the tablet formulation of roxithromycin dispersible tablet with limited experiment.

  • PDF

Adaptive Contrast Enhancement in DCT Domain (DCT영역에서의 적응적 대비 개선에 관한 연구)

  • Jeon, Yong-Joon;Eom, Min-Young;Choe, Yoon-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.73-78
    • /
    • 2005
  • Images coded by DCT based compression contain several quality degradations by quantization process. Among them contrast distortion is the important one because human eyes are sensitive to contrast. In case of low bit-rate coded image, we can not get an image having good quality due to quantization error. In this paper, we suggest a new scheme to enhance image's contrast in DCT domain. Proposed method enhances only edge regions. Homogeneous regions are not considered in this method. $8{\times}8$ DCT coefficient blocks are decomposed to $4{\times}4$ sub-blocks for detail edge region discrimination. we could apply this scheme to real-time application because proposed scheme is DCT based method.

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Electro-mechanical impedance based strength monitoring technique for hydrating blended cements

  • Thirumalaiselvi, A.;Sasmal, Saptarshi
    • Smart Structures and Systems
    • /
    • v.25 no.6
    • /
    • pp.751-764
    • /
    • 2020
  • Real-time monitoring of stiffness and strength in cement based system has received significant attention in past few decades owing to the development of advanced techniques. Also, use of environment friendly supplementary cementitious materials (SCM) in cement, though gaining huge interest, severely affect the strength gain especially in early ages. Continuous monitoring of strength- and stiffness- gain using an efficient technique will systematically facilitate to choose the suitable time of removal of formwork for structures made with SCM incorporated concrete. This paper presents a technique for monitoring the strength and stiffness evolution in hydrating fly ash blended cement systems using electro-mechanical impedance (EMI) based technique. It is important to observe that the slower pozzolanic reactivity of fly ash blended cement systems could be effectively tracked using the evolution of equivalent local stiffness of the hydrating medium. Strength prediction models are proposed for estimating the strength and stiffness of the fly ash cement system, where curing age (in terms of hours/days) and the percentage replacement of cement by fly ash are the parameters. Evaluation of strength as obtained from EMI characteristics is validated with the results from destructive compression test and also compared with the same obtained from commonly used ultrasonic wave velocity (UPV). Statistical error indices indicate that the EMI technique is capable of predicting the strength of fly ash blended cement system more accurate than that from UPV. Further, the correlations between stiffness- and strength- gain over the time of hydration are also established. From the study, it is found that EMI based method can be effectively used for monitoring of strength gain in the fly ash incorporated cement system during hardening.