• Title/Summary/Keyword: composite shear connector

검색결과 200건 처리시간 0.023초

Behavior and resistance of truss-type shear connector for composite steel-concrete beams

  • Lima, Jerfson M.;Bezerra, Luciano M.;Bonilla, Jorge;Silva, Ramon S.Y.R.C.;Barbosa, Wallison C.S.
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.569-586
    • /
    • 2020
  • The behavior of composite steel-concrete beams depends on the transmission of forces between two parts: the concrete slab and the steel I-beam. The shear connector is responsible for the interaction between these two parts. Recently, an alternative shear connector, called Truss Type connector, has been developed; it aligns efficient structural behavior, fast construction and implementation, and low cost when compared to conventional connectors applied in composite structures. However, there is still a lack of full understanding of the mechanical behavior of the Truss Type connector, due to its novelty. Thus, this study aims to analyze the influence of variation of geometric and physical parameters on the shear resistance of the Truss Type connector. In order to investigate those parameters, a non-linear finite element model, able to simulate push-out tests of Truss Type connectors, was specifically developed and validated with experimental results. A thorough parametric study, varying the height, the angle between rods, the diameter, and the concrete strength, was conducted to evaluate the shear resistance of the Truss Type connector. In addition, an equation to predict the resistance of the original Truss Type shear connector was proposed.

역T형강 합성보의 전단연결에 관한 실험적 연구 (An Experimental Study on the Shear Connection of Inverted T-shape Composite Beam Encased Web)

  • 정재훈;김진무
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.131-138
    • /
    • 2001
  • In inverted T-shape composite beam examine the structural behavior by experiment According to arrangement, type of stud connector, type of shear connector, reinforcement by welding of stirrup and a close analysis we came to these conclusion. 1) The compare result of bending strength according to arrange type of stud connector : A1-W(stud connector located web)specimen is exceed than A1-F(stud connector located flange). 2) B1-N(using prominence and depression of the web by shear connector) specimen is decrease than A1-W(using stud bolt by shear connector)specimen in bending strength and B2-N(reinforced by welding the stirrup to lower flange)specimen is similar with A2-W specimen. 3) According to reinforced by welding the stirrup to flange, the stiffness and bending strength of the beams are increase. A-scries stirrup comparatively low effective in the increase of strength by welding the stirrup to flange because enough composite effect show by stud connector, but B-series stirrup is comparatively high effective in shear connector effect because shortage of prominence and depression of the web.

  • PDF

Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams

  • Qi, Jingjing;Xie, Zuwei;Cao, Hua;Huang, Zhi;Lv, Weirong;Shi, Weihua
    • Structural Engineering and Mechanics
    • /
    • 제83권6호
    • /
    • pp.789-798
    • /
    • 2022
  • The stud shear connector is the main force transfer member in the steel-concrete composite member, and the mechanical behavior is very complicated in the concrete. The concrete around the stud is subjected to the pry-out local pressure concentration of the stud, which can easily produce splitting mirco-cracks. In order to solve the problem of pry-out local splitting of stud shear connector, a kind of stud shear connector with constraint measure is proposed in this paper. Through the push-out test, the interface shear behavior of the new stud shear connector between steel and concrete flange plate was studied, and the difference between the new stud shear connector and the traditional stud connector was compared. The results show that the stud shear connector with constraint measure can effectively avoid the adverse effect of local pressure splitting by relying on its own constraint measure. The shear stiffness of the interface between steel and concrete flange plates is greatly improved, which provides a theoretical basis for the design of strong connection coefficient of steel-concrete composite structures.

T형 합성보의 시어 커넥터 형상에 따른 전단내력 평가에 관한 연구 (An Evaluation on the Shear Strength for Different Forms of Shear Connector in T-type Composite Beam)

  • 김성배;김상섭
    • 한국강구조학회 논문집
    • /
    • 제18권2호
    • /
    • pp.279-288
    • /
    • 2006
  • 합성보의 전단연결재는 국내외에서 연구가 진행되어 콘크리트 슬래브와 철골보의 합성율을 개선시킬 수 있는 디테일이 많이 개발되어 사용 중에 있다. 현재 보편적으로 사용되는 스터드는 내력산정의 편이성과 시공성 등이 조합되어 가장 많이 적 용되고 있으나, 철근이나 ㄷ형강 등도 일부 개발되어 적용되고 있다. 본 연구는 합성보 연구의 일부로서 기존에 사용되던 스터드와 동등 이상의 내력과 연성을 확보할 수 있는 전단연결재를 개발하고, 합성보의 시어 커넥터에 대한 구조설계 및 시공에 필요한 기초 자료를 제시한 것이다.

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

Shear behavior of multi-hole perfobond connectors in steel-concrete structure

  • Xing, Wei;Lin, Xiao;Shiling, Pei
    • Structural Engineering and Mechanics
    • /
    • 제56권6호
    • /
    • pp.983-1001
    • /
    • 2015
  • This study focuses on the load carrying capacity and the force transfer mechanism of multi-hole perfobond shear connectors in steel-concrete composite structure. The behavior of multi-hole perfobond shear connector is more complicated than single-hole connector cases. 2 groups push-out tests were conducted. Based on the test results, behavior of the connection was analyzed and the failure mechanism was identified. Simplified iterative method and analytic solution were proposed based on force equilibrium for analyzing multi-hole perfobond shear connector performance. Finally, the sensitivity of design parameters of multi-hole perfobond shear connector was investigated. The results of this research showed that shear force distribution curve of multi-hole perfobond shear connector is near catenary. Shear forces distribution were determined by stiffness ratio of steel to concrete member, stiffness ratio of shear connector to steel member, and number of row. Efficiency coefficient was proposed to should be taking into account in different limit state.

합성거동을 위한 유공판형 전단연결재의 강도평가에 관한 연구 (A Study on the Evaluation of Shear Resisting Capacity for the Various Perforated Shape Shear Connector)

  • 김영호
    • Composites Research
    • /
    • 제21권5호
    • /
    • pp.1-8
    • /
    • 2008
  • 강합성교량에서 스터드 전단연결재 및 Perfobond 전단연결재와 관련된 문제를 해결하고, 콘크리트와 전단연결재가 동시에 파괴되도록 유도하기 위해 역 L형 유공판 전단연결재가 개발되었으며, FRP-콘크리트 합성바닥판에서는 FRP의 재료적 특성과 펄트루젼 생산방식을 고려하여 콘크리트와 FRP의 합성방안으로 Perfobond 형 FRP 전단연결재를 적용하고 있다. 이 연구는 기존 강재 Perfobond 전단연결재에 대한 문헌분석, 2면전단실험, 유한요소해석 등의 방법을 통해 역 L형 유공판 전단연결재, FRP 전단연결재에 대한 각각의 강도를 추정할 수 있는 강도평가식을 제안하였고, 제안한 평가식의 결과와 실험결과를 비교하여 타당성을 검증하였다.

ㄱ형 Perfobond 리브 전단연결재의 적용성 평가 (Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors)

  • 이흥수;정철헌;김병석;강재윤;손유식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

Shear behavior of a demountable bolted connector in steel-UHPC lightweight composite structures

  • Gu, Jin-Ben;Wang, Jun-Yan
    • Structural Engineering and Mechanics
    • /
    • 제81권5호
    • /
    • pp.551-563
    • /
    • 2022
  • Bolted connector could be an alternative to replace the conventional welded headed stud in steel-ultra high performance concrete (UHPC) lightweight composite structures. In this paper, a novel demountable bolted shear connector, consisting of a high-strength bolt (HSB) and a specially-designed nut which is pre-embedded in a thin UHPC slab, is proposed, which may result in the quick installation and disassembly, due to the mountable, demountable and reusable features. In order to study the shear behavior of the new type of bolted shear connector, static push-out tests were conducted on five groups of the novel demountable bolted shear connector specimens and one group of conventional welded headed stud specimen for comparison. The effect of the bolt shank diameter and aspect ratio of bolt on failure mode, shear stiffness, peak slip at the steel-UHPC interface, shear strength and ductility of novel bolted connectors is investigated. Additionally, design formula for the shear strength is proposed to check the suitability for assessment of the novel demountable bolted shear connectors.

합성작용을 위한 새로운 Perfobond T형 전단연결재 (A New T Type Perfobond Shear Connector for Composite Action)

  • 정철헌;김종석;심창수;김광수;정광회;심정욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.293-296
    • /
    • 2006
  • The results and interpretations of push-out tests on shear connector devices for composite bridges carried out in this study are presented. The devices under investigations are headed studes, perfobond rib, ㄱtype perfobond rib, T- Connector and a new type of shear connector called T type perfobond rib. This new connector is flat steel plate with a number of holes punched through. The results obtained indicate that the T type perfobond rib shear connectors exhibit adequate ductility and substantially higher capacities. Therefore for composite beams utilizing reinforced concrete slabs, the T type perfobond rib shear connectors is a viable alternative to the headed studs.

  • PDF