• Title/Summary/Keyword: composite repaired structures

Search Result 64, Processing Time 0.02 seconds

Effect of curing condition on mechanical properties of scarf-repaired composite laminates

  • Cheng, Xiaoquan;Zhang, Jie;Cheng, Yujia;Guo, Xin;Huang, Wenjun
    • Steel and Composite Structures
    • /
    • v.37 no.4
    • /
    • pp.419-429
    • /
    • 2020
  • Composite structures are generally pressurized at both sides when repaired by the scarf repair method. But single-face vacuum bag curing (SVC) may be used in some practical scarf repair of penetration damage due to the low accessibility of composite structures, which can decrease bonding quality and may reduce structural mechanical properties. In this paper, experimental investigations were conducted on tensile and compressive properties of scarf-repaired composite laminates using SVC and double-face vacuum bag curing (DVC) in four hygrothermal environments. Finite element models of composite scarf joints with voids were established to further explore the failure mechanism of scarf-repaired laminates. Results show that the curing condition hardly affects tensile and compressive properties of the repaired laminates though it significantly affects the bonding quality with adhesive inner voids. Failure loads of scarf joints almost keep unchanged with adhesive voids increasing.

FATIGUE CRACK GROWTH MONITORING OF CRACKED ALUMINUM PLATE REPAIRED WITH COMPOSITE PATCH USING EMBEDDED OPTICAL FIBER SENSORS (광섬유센서를 이용한 복합재 패치수리된 알루미늄판의 균열관찰)

  • 서대철;이정주;김상훈
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.250-253
    • /
    • 2001
  • Recently, based on the smart structure concept, optical fiber sensors have been increasingly applied to monitor the various engineering and civil structural components. Repairs based on adhesively bonded fiber reinforce composite patches are more structurally efficient and much less damaging to the parent structure than standard repairs based on mechanically fastened metallic patches. As a result of the high reinforcing efficiency of bonded patches fatigue cracks can be successfully repaired. However, when such repairs are applied to primary structures, it is needed to demonstrate that its loss can be immediately detected. This approach is based on the "smart patch" concept in which the patch system monitors its own health. The objective of this study is to evaluate the potentiality of application of transmission-type extrinsic Fabry-Perot optical fiber sensor (TEFPI) to the monitoring of crack growth behavior of composite patch repaired structures. The sensing system of TEFPI and the data reduction principle for the detection of crack detection are presented. Finally, experimental results from the tests of center-cracked-tension aluminum specimens repaired with bonded composite patch is presented and discussed.

  • PDF

Analysis of interfacial stresses of the reinforced concrete foundation beams repairing with composite materials plate

  • Abderezak, Rabahi;Daouadji, Tahar Hassaine;Rabia, Benferhat
    • Coupled systems mechanics
    • /
    • v.9 no.5
    • /
    • pp.473-498
    • /
    • 2020
  • This paper presents a careful theoretical investigation into interfacial stresses in reinforced concrete foundation beam repairing with composite plate. The essential issue in the analysis of reinforced structures with composite materials is to understand the individual behaviour of each material and its interaction with the remaining ones. The present model is based on equilibrium and deformations compatibility requirements in and all parts of the repaired RC foundation beam, i.e., the reinforced concrete foundation beam, the composite plate and the adhesive layer. The theoretical predictions are compared with other existing solutions, By comparisons between the existing solutions and the present new solution enable a clear appreciation of the effects of various parameters such as the geometric characteristics and mechanical properties of the components of the repaired beam, as well as the geotechnical stresses of the soil are considered. This research is helpful for the understanding on mechanical behaviour of the interface and design of the composite-concrete hybrid structures.

Numerical Simulation of Rehabilitated Flexural RC Member using High Performance Composite (균열제어 기능성 복합재료를 이용한 RC 휨 부재 보강수치해석)

  • 신승교;김태균;임윤묵
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.543-548
    • /
    • 2003
  • In this study, a numerical model is developed using axial deformation link elements that can effectively predict the failure behavior of RC type structures. Using this mod 1, numerical analysis was performed to investigate the strengthening effect and failure behavior of structures repaired with a new material. High-Performance Cementitious Composites, which is characterized by its ductility with 5% strain-capacity is used as a repair material. To investigate the validity of developed numerical model, simulations of direct tension specimen and flexural specimen are performed and the results are compared with published ones. The similar analysis is performed for RC beam. Through this study, it is seen that predicted response has a good agreement with the experimental results. Using this verified numerical model, the strengthening effect of repaired with HPCC structure is analyzed through load-displacement curve and failure modes. Also, the same numerical analysis is performed in RC beam repaired with HPCC. The effect of HPCC ductility is estimated for the overall behavior of structures. Based on the results, the fundamental data are suggested for repaired structures with HPCC.

  • PDF

Numerical analysis of the Influence of the presence of disbond region in adhesive layer on the stress intensity factors (SIF) and crack opening displacement (COD) in plates repaired with a composite patch

  • Benchiha, Aicha;Madani, Kouider;Touzain, Sebastien;Feaugas, Xavier;Ratwani, Mohan
    • Steel and Composite Structures
    • /
    • v.20 no.4
    • /
    • pp.951-962
    • /
    • 2016
  • The determination of the stress intensity factor at the crack tip is one of the most widely used methods to predict the fatigue life of aircraft structures. This prediction is more complicated for repaired cracks with bonded composite patch. This study is used to compute the stress intensity factor (SIF) and crack opening displacement (COD) for cracks repaired with single and double-sided composite patches. The effect of the presence of disbond region in adhesive at the crack was taken into consideration. The results show that there is a considerable reduction in the asymptotic value of the stress-intensity factors and the crack opening displacement at the crack tip. The use of a double-sided patch suppresses the bending effect due to the eccentricity of the patch on one side only.

Numerical analysis of the behaviour of repaired surface cracks with bonded composite patch

  • Merzoug, Mohamed;Boulenouar, Abdelkader;Benguediab, Mohamed
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.209-216
    • /
    • 2017
  • In this paper, the analysis of the behavior of surface cracks in finite-thickness plates repaired with a Boron/Epoxy composite patch is investigated using three-dimensional finite element methods. The stress intensity factor at the crack-front was used as the fracture criteria. Using the Ansys Parametric Design Language (APDL), the stress intensities at the internal and external positions of repaired surface crack were compared. The effects of the mechanical and geometrical properties of the adhesive layer and the composite patch on the variation of the stress intensity factor at the crack-front were examined.

Finite element analysis of corner cracked aluminum panels repaired with bonded composite patch

  • Abdelkader Boulenouar;Mohammed A. Bouchelarm;Noureddine Benseddiq
    • Steel and Composite Structures
    • /
    • v.49 no.3
    • /
    • pp.271-280
    • /
    • 2023
  • In this study, the three-dimensional finite element method is used to analyze the behavior of corner cracks in finite-thickness plates repaired with a composite patch. The normalized stress intensity factor at the crack front is used as fracture criterion. Comparison of stress intensity factor values at the internal and external positions of repaired quarter-elliptical corner crack was done, for three repair techniques. The influence of mechanical and geometrical properties of the adhesive layer and the composite patch on the variation of the stress intensity factor (SIF) at the crack-front was highlighted. The obtained results show that the application of double patch leads to a remarkable reduction of SIF at the crack front, compared to facial and lateral repairs.

Numerical study of bonded composite patch repair in damaged laminate composites

  • Azzeddine, Nacira;Benkheira, Ameur;Fekih, Sidi Mohamed;Belhouari, Mohamed
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.2
    • /
    • pp.151-168
    • /
    • 2020
  • The present study deals with the repair of composite structures by bonding composite patches. The composite structure is a carbon/epoxy laminate with stacking sequence [45/-45/0/90]S. The damaged zone is simulated by a central crack and repaired by bonding symmetrical composite patches. The repair is carried out using composite patches laminated from the same elemental folds as those of the cracked specimen. Three-dimensional finite element method is used to determine the energy release rate along the front of repaired crack. The effects of the repair technique used single or double patch, the stacking sequence of the cracked composite patch and the adhesive properties were highlighted on the variations of the fracture energy in mode I and mixed mode I + II loading.

Study on the Monitoring Method of Concrete Structure Repaired by Carbon Sheets with Optical Fiber Sensors (콘크리트구조물의 탄소섬유시트에 의한 구조 보강시 광섬유 센서를 이용한 모니터링기법에 관한 연구)

  • Kim, Ki-Soo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.149-152
    • /
    • 2005
  • In order to extend the life time of building and civil infra-structure, nowadays, patch type carbon sheets are widely used as repairing meterials. Repaired concrete columns and beams with carbon sheets gain their stiffness and strength, but they lose toughness and show brittle failure behaviors. Usually, the cracks of concrete structures are visible with naked eyes and the status of the structure in the life cycle is estimated with visible inspection. After repairing of the structure, crack visibility is blocked by repaired carbon sheets. Therefore, structural monitoring after repairing is indispensible and self diagnosis method with optical fiber sensor is very useful. In this paper, peel-out effects is detected with optical fiber sensors and the strain difference between main structure and repaired carbon sheets when they separate each other.

  • PDF