• Title/Summary/Keyword: composite pipes

Search Result 116, Processing Time 0.036 seconds

A Numerical Study on Reinforced effect of the Railway Tunnel by Umbrella Arch Method (Umbrella Arch 공법이 적용된 철도터널의 강관보강효과에 관한 수치해석적 연구)

  • Lee Hyun Suk;Lee Jun S.;Bang Chun Suk;Kim Yun Tae
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1090-1095
    • /
    • 2004
  • Umbrella Arch Method(UAM), among others. is commonly applied to increase the facial stability during tunnel excavation and, depending on the field condition, additional reinforcement techniques can be used simultaneously. UAM, together with grouting method, is normally used to reduce ground permeability and improve stability of the tunnel by inserting a series of steel pipes into the ground around the crown inclined to the longitudinal axis of the tunnel. However. there has not been much rigorous study on the effectiveness of UAM, and most of UAM installations depend on empirical judgement rather than on engineering calculation, .In this study, the effectiveness of UAM is demonstrated based on the constitutive relationship involving UAM derived from the mechanics of composite material, and the numerical investigation is compared with small scale experiments on the tunnel reinforcement.

  • PDF

Fracture behavior using AE method and reliability assessment of CFRP based on absorbed moisture (흡습된 CFRP의 AE에 의한 파과거동과 신뢰성 평가)

  • 남기우;김선진
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.38-50
    • /
    • 1996
  • Recently carbon fiber reinforced plastic (CFRP) has been used structural materials in corrosive environment such as for water, chemical tank and pipes. However, mechanical properties of such materials may be change when CFRP and exposed to corrosive environment for long periods of time. The degradation behavior of carbon fiber/epoxy resin composite material in distilled water is investigated using acoustic emission (AE) technique, Fracture toughness tests are performed on the compact tension specimens that are pilled by two types of $[O_2/9O_2]_{3s}$ and $[O/9O]_6s$. During the testes, AE test was carried out to monitor the damage of CFRP by moisture absorption. The data was treated by 2-parameter Weibull distribution and the fracture surface was observed by scanning electron microscope.

  • PDF

Vibration and instability of nanocomposite pipes conveying fluid mixed by nanoparticles resting on viscoelastic foundation

  • Natanzi, Abolfazl Jafari;Jafari, Gholamreza Soleimani;Kolahchi, Reza
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.569-582
    • /
    • 2018
  • In this study, nonlinear vibration and stability of a polymeric pipe reinforced by single-walled carbon naotubes (SWCNTs) conveying fluid-nanoparticles mixture flow is investigated. The Characteristics of the equivalent composite are determined using Mori-Tanaka model considering agglomeration effects. The surrounding elastic medium is simulated by orthotropic visco-Pasternak medium. Employing nonlinear strains-displacements, stress-strain energy method the governing equations were derived using Hamilton's principal. Differential quadrature method (DQM) is used for obtaining the frequency and critical fluid velocity. The influence of volume percent of SWCNTs, agglomeration, geometrical parameters of pipe, viscoelastic foundation and fluid velocity are shown on the frequency and critical fluid velocity of pipe. Results showed the increasing volume percent of SWCNTs leads to higher frequency and critical fluid velocity.

Reinforcement of Polyethylene Pipes with Modified Carbon Microfibers

  • Petukhova, E.S.;Savvinova, M.E.;Krasnikova, I.V.;Mishakov, I.V.;Okhlopkova, A.A.;Jeong, Dae-Yong;Cho, Jin-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.3
    • /
    • pp.177-180
    • /
    • 2016
  • The surface properties of carbon microfibers (CMFs) are modified by chemical deposition of carbon nanofibers via the so-called ethylene processing. CMFs and the modified CMFs (MCMFs) are investigated as reinforcement additives to fabricate polyethylene (PE) composites with enhanced mechanical characteristics. The mechanical properties of the PE-MCMF composites are found to be better and favorable for applications under harsh climatic conditions such as those in Siberia. Improved adhesive interaction between MCMFs and PE is responsible for these enhanced mechanical properties.

State-of-the-Art Review of Ferro-cement Boat (Ferro-cement Boat 건조 보고)

  • Sun-Young,Pak
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.8 no.1
    • /
    • pp.103-118
    • /
    • 1971
  • Ferro-cement is a composite material made of portland cement mortar and wire(or chicken wire) reinforcement. In most cases, as a shipbuilding material, reinforcing steel rods and steel pipes are also used. This report will review the technique of ferro-cement boat building and will guide the working details. Beyond these, this report will present some test results of the ferro-cement test pannels and will compare those with the other well known shipbuilding material. As a matter of fact ferro-cement application to the shipbuilding material is quite not a new theory. There were already lots of case studies and actual ship building applications. But the technique to do this is not easily available to the interested persons and amateur shipbuilders. Therefore this report will stress most its "state-of-the-art review" and give kind guidance in using ferro-cement as a shipbuilding material. For the more interested research worker, technical references as much as listable are printed in the bibliography section on this report.

  • PDF

Constitutive model coupled with damage for carbon manganese steel in low cycle fatigue

  • Huang, Zhiyong;Wang, Qingyuan;Wagner, Daniele;Bathias, Claude
    • Steel and Composite Structures
    • /
    • v.17 no.2
    • /
    • pp.185-198
    • /
    • 2014
  • Carbon-manganese steel A42 (French standards) is used in steam generator pipes of nuclear center and subject to low cycle fatigue (LCF) loads. In order to obtain the material LCF behavior, the tests are implemented in a hydraulic fatigue machine. The LCF plastic deformation and cyclic stress in macroscope have been influenced by the accumulated low cycle fatigue damage. The constitutive kinematic and isotropic hardening modeling is modified with coupling fatigue damage to describe the fatigue behavior. The improved model seems to be good agreement with the test results.

Simulation and modeling for stability analysis of functionally graded non-uniform pipes with porosity-dependent properties

  • Peng Zhang;Jun Song;Tayebeh Mahmoudi
    • Steel and Composite Structures
    • /
    • v.48 no.2
    • /
    • pp.235-250
    • /
    • 2023
  • The present paper examines the stability analysis of the buckling differentiae of the small-scale, non-uniform porosity-dependent functionally graded (PD-FG) tube. The high-order beam theory and nonlocal strain gradient theory are operated for the mathematical modeling of nanotubes based on the Hamilton principle. In this paper, the external radius function is non-uniform. In contrast, the internal radius is uniform, and the cross-section changes along the tube length due to these radius functions based on the four types of useful mathematical functions. The PD-FG material distributions are varied in the radial direction and made with ceramics and metals. The governing partial differential equations (PDEs) and associated boundary conditions are solved via a numerical method for different boundary conditions. The received outcomes concerning different presented parameters are valuable to the design and production of small-scale devices and intelligent structures.

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

Study of structural properties and development of high strength Cured-In-Place Pipe (CIPP) liner for sewer pipes using glass fiber (유리섬유를 이용한 하수관의 고강도 현장경화 비굴착 보수 공법 재료의 개발 및 물성 특성 연구)

  • Ji, Hyon Wook;Koo, Dan Daehyun;Yoo, Sung Soo;Kang, Jeong-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.149-159
    • /
    • 2020
  • Cured-in-place-pipe(CIPP) is the most adopted trenchless application for sewer rehabilitation to extend the life of the existing sewer without compromising both direct construction and indirect social costs especially applied in the congested urban area. This technology is globally and domestically known to be the most suitable for partial and full deteriorated pipe structure rehabilitation in a sewer system. The typical design of CIPP requires a significant thickness of lining to support loading causing sewage flow interruption and increasing material cost. This paper presents development of a high strength glass fiber composite lining material for the CIPP application and structural test results. The test results exhibit that the new glass fiber composite lining material has 12 times of flexural strength, 6.2 times of flexural modulus, and 0.5 Creep Retention Factor. These test results can reduce lining design thickness 35% at minimum. Even though taking into consideration extra materials such as outer and inner films for actual field applications, the structural capacity of the composite material significantly increases and it reduces 20 percent or more line thickness as compared to the conventional CIPP. We expect that the newly developed CIPP lining material lowers material costs and minimizes flow capacity reduction, and fully replaceable to the conventional CIPP lining materials.