• Title/Summary/Keyword: composite graft.

Search Result 186, Processing Time 0.033 seconds

Preserved Superficial Fat Skin Composite Graft for Correction of Burn Scar Contracture of Hand (얕은 지방층을 포함한 피부복합조직이식을 이용한 손화상 반흔구축의 교정)

  • Son, Daegu;Jeong, Hoijoon;Choi, Taehyun;Kim, Junhyung;Han, Kihwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.716-722
    • /
    • 2008
  • Purpose: Split or full thickness skin graft is generally used to reconstruct the palmar skin and soft tissue defect after release of burn scar flexion contracture of hand. As a way to overcome and improve aesthetic and functional problems, the authors used the preserved superficial fat skin(PSFS) composite graft for correction of burn scar contracture of hand. Methods: From December of 2001 to July of 2007, thirty patients with burn scar contracture of hand were corrected. The palmar skin and soft tissue defect after release of burn scar contracture was reconstructed with the PSFS composite graft harvested from medial foot or below lateral and medial malleolus, with a preserved superficial fat layer. To promote take of the PSFS composite graft, a foam and polyurethane film dressing was used to maintain the moisture environment and Kirschner wire was inserted for immobilization. Before and after the surgery, a range of motion was measured by graduator. Using a chromameter, skin color difference between the PSFS composite graft and surrounding normal skin was measured and compared with full thickness skin graft from groin. Results: In all cases, the PSFS composite graft was well taken without necrosis, although the graft was as big as $330mm^2$(mean $150mm^2$). Contracture of hand was completely corrected without recurrence. The PSFS composite graft showed more correlations and harmonies with surrounding normal skin and less pigmentation than full thickness skin graft. Donor site scar was also obscure. Conclusion: The PSFS composite graft should be considered as a useful option for correction of burn scar flexion contracture of hand.

A COMPARATIVE STUDY ON THE STRENGTH AND THE BONE FORMATION AT THE RATS CALVARIAL DEFECTS OF DFDB GRAFT AND THOSE OF THE COMPOSITE GRAFT WITH DFDB AND RESORBABLE HYDROXYAPATITE (백서 두개골 결손부에 동결 건조 동종 탈회골을 단일매식한 경우와 동결 건조 동종 탈회골과 흡수성 수산화인회석을 복합매식한 경우의 강도 및 골형성에 관한 비교 연구)

  • Seo, Young-Ho;Yim, Chang-Joon;Lee, Jae-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.557-564
    • /
    • 2000
  • The bone graft materials can be grossly divided into autogenous bone, allogenic bone, xenogenic bone, and alloplastic material. Much care was given to other bone graft materials away from autogenous bone due to its additional operation for harvesting, delayed resorption and limitation of quantity. Demineralized freeze-dried bone(DFDB) and hydroxyapatite are the representatives of bone graft materials. As resorbable hydroxyapatite is developed in these days, the disadvantage of nonresorbability can be overcome. So we planned to study on the strength and the bone formation at the rats calvarial defects of DFDB graft and those of the composite graft with DFDB and resorbable hydroxyapatite. We used the 16 male rats weighting range from 250 to 300 gram bred under the same environment during same period. After we made the 6mm diameter calvarial defect, we filled the DFDB in 8 rats and DFDB and resorbable hydroxyapatite in another 8 rats. We sacrificed them at the postoperative 1 month and 2 months with the periostium observed. As soon as the specimens were delivered, we measured the compressive forces to break the normal calvarial area and the newly formed bone in calvarial defect area using Instron(Model Autograph $S-2000^{(R)}$, Shimadzu, Japan). The rest of the specimens were stained with H&E(Hematoxylin & Eosin) and evaluated with the light microscope. So we got the following results. 1. In every rats, there was no significant difference between the measured forces of normal bone area and those of the bone graft area. 2. In 1 month, the measured forces at DFDB graft group were higher than those of the DFDB and resorbable hydroxyapatite composite graft group(P<0.05). 3. In 2 months, there was no significant differences between the measured forces of DFDB graft group and those of the DFDB and resorbable hydroxyapatite composite graft group. 4. In lightmicroscopic examination, most of the grafted DFDB were transformed into bone in 1 month and a large numbers of hydroxyapatite crystal were observed in DFDB and resorbable hydroxyapatite composite graft group in 1 month. 5. Both group showed no inflammatory reaction in 1 month. And hydroxyapatite crystals had a tight junction without soft tissue invagination when consolidated with newly formed bone. 6. In both groups, newly formed bone showed the partial bone remodeling and the lamellar bone structures and some of reversal lines were observed in 2 months. From the above results, it is suggested that DFDB and resorbable hydroxyapatite composite graft group had a better resistance to compressive force in early stage than DFDB graft group, but there would be no significant difference between two groups after some period. And it is suggested that the early stage of bone formation procedure of DFDB and resorbable hydroxyapatite composite graft group was slight slower than that of DFDB graft group, but there would be no significant difference between two groups after some period.

  • PDF

Outcomes and Patency of Complex Configurations of Composite Grafts Using Bilateral Internal Thoracic Arteries

  • Shih, Beatrice Chia-Hui;Chung, Suryeun;Kim, Hakju;Chang, Hyoung Woo;Kim, Dong Jung;Lim, Cheong;Park, Kay-Hyun;Kim, Jun Sung
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.64-72
    • /
    • 2020
  • Background: It is generally agreed that using a bilateral internal thoracic artery (BITA) composite graft improves long-term survival after coronary artery bypass grafting (CABG). Although the left internal thoracic artery (LITA)-based Y-composite graft is widely adopted, technical or anatomical difficulties necessitate complex configurations. We aimed to investigate whether BITA configuration impacts survival or patency in patients undergoing coronary revascularization. Methods: Between January 2006 and June 2017, 1,161 patients underwent CABG at Seoul National University Bundang Hospital, where the standard technique is a LITA-based Y-composite graft with the right internal thoracic artery (RITA) sequentially anastomosed to non-left anterior descending (LAD) targets. Total of 160 patients underwent CABG using BITA with modifications. Their medical records and imaging data were reviewed retrospectively to investigate technical details, clinical outcomes, and graft patency. Results: Modifications of the typical Y-graft (group 1, n=90), LITA-based I-graft (group 2, n=39), and RITA-based composite graft (group 3, n=31) were used due to insufficient RITA length (47%), problems using LITA (28%), and target vessel anatomy (25%). The overall 30-day mortality rate was 1.9%. Among 116 patients who underwent computed tomography or conventional angiography at a mean interval of 29.9±33.1 months postoperatively, the graft patency rates were 98.7%, 95.3%, and 83.6% for the LAD, left circumflex artery, and right coronary artery territories, respectively. Patency rates for the inflow, secondary, and tertiary grafts were 98.2%, 90.5%, and 80.4%, respectively. The RITA-based graft (group 3) had the lowest patency rate of the various configurations (p<0.011). Conclusion: LITA-based Y composite graft, showed satisfactory clinical outcomes and patency whereas modifications of RITA- based composite graft had the lowest patency and 5-year survival rates. Therefore, when using RITA-based composite graft, other options should be considered before proceeding atypical configurations.

The Effect of Platelet-Rich Plasma on Survival of the Composite Graft and the Proper Time of Injection in a Rabbit Ear Composite Graft Model

  • Choi, Hyun Nam;Han, Yea Sik;Kim, Sin Rak;Kim, Han Kyeol;Kim, Hyun;Park, Jin Hyung
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.647-653
    • /
    • 2014
  • Background Administration of growth factors has been associated with increased viability of composite grafts greater than 1-cm in diameter. Platelet-rich plasma (PRP) contains many of the growth factors studied. In this study, we evaluate the effect of PRP injection on composite graft viability and the proper time for injection. Methods A total of 24 New Zealand White rabbits were divided into four groups. Autologous PRP was injected into the recipient sites three days before grafting in group 1, on the day of grafting in group 2, and three days after grafting in group 3. Group 4 served as control without PRP administration. Auricular composite grafts of 3-cm diameter were harvested and grafted back into place after being rotated 180 degrees. Median graft viability and microvessel density were evaluated at day 21 of graft via macroscopic photographs and immunofluorescent staining, respectively. Results The median graft survival rate was 97.8% in group 1, 69.2% in group 2, 55.7% in group 3, and 40.8% in the control group. The median vessel counts were 34 (per ${\times}200$ HPF) in group 1, 24.5 in group 2, 19.5 in group 3, and 10.5 in the control group. Conclusions This study demonstrates that PRP administration is associated with increased composite graft viability. All experimental groups showed a significantly higher survival rate and microvessel density, compared with the control group. Pre-administration of PRP was followed by the highest graft survival rate and revascularization. PRP treatments are minimally invasive, fast, easily applicable, and inexpensive, and offer a potential clinical pathway to larger composite grafts.

Use of an Interposition Tube Graft for the Reattachment of Left Coronary Ostium to the Aortic Composite Valve Graft. -One Case- (Aortic Composite Valve Graft의 이식시 인조혈관을 이용한 좌 관상동맥의 문합술 1례 보고)

  • Kim, Chang-Nam;Choe, Jong-Beom;Choe, Hyeong-Ho
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.646-650
    • /
    • 1996
  • The usual methods for the re-attachment of coronary ostia to the ascending aortic conduit have several disadvantages and potential complications. A novel, straight forward technique is described that allows for tension free anastomoses to be co structed with minimal risk of blood loss and a reduced risk of reoperation for false aneurysms at the anastomoses. We performed this technique for the treatment of a 40-yrs-old male patient of acute aortic dissection (Stanford Type A, DeBakey Type I) with severe aortic re- gurgitation. The techinque comprised anastomosis of a beveled interposition tube graft to the left main coronary artery ostium, and its proximal anastomosis to the ascending aortic graft after seating the com- posite valve graft in the prepared aortic annulus. With this technique, the low-Iying or distant left main coronary ostium can be easily reattached to the ascending conduit without undue tension.

  • PDF

Large Auricular Chondrocutaneous Composite Graft for Nasal Alar and Columellar Reconstruction

  • Son, Daegu;Kwak, Minho;Yun, Sangho;Yeo, Hyeonjung;Kim, Junhyung;Han, Kihwan
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.323-328
    • /
    • 2012
  • Background Among the various methods for correcting nasal deformity, the composite graft is suitable for the inner and outer reconstruction of the nose in a single stage. In this article, we present our technique for reconstructing the ala and columella using the auricular chondrocutaneous composite graft. Methods From 2004 to 2011, 15 cases of alar and 2 cases of columellar reconstruction employing the chondrocutaneous composite graft were studied, all followed up for 3 to 24 months (average, 13.5 months). All of the patients were reviewed retrospectively for the demographics, graft size, selection of the donor site and outcomes including morbidity and complications. Results The reasons for the deformity were burn scar (n=7), traumatic scar (n=4), smallpox scar (n=4), basal cell carcinoma defect (n=1), and scar contracture (n=1) from implant induced infection. In 5 cases of nostril stricture and 6 cases of alar defect and notching, composite grafts from the helix were used ($8.9{\times}12.5$ mm). In 4 cases of retracted ala, grafts from the posterior surface of the concha were matched ($5{\times}15$ mm). For the reconstruction of the columella, we harvested the graft from the posterior scapha ($9{\times}13.5$ mm). Except one case with partial necrosis and delayed healing due to smoking, the grafts were successful in all of the cases and there was no deformity of the donor site. Conclusions An alar and columellar defect can be reconstructed successfully with a relatively large composite graft without donor site morbidity. The selection of the donor site should be individualized according to the 3-dimensional configuration of the defect.

Usefulness of Inferior Turbinate Bone-Periosteal-Mucosal Composite Free Graft for Cerebrospinal Fluid Leakage (하비갑개 골-골막-점막 복합이식을 이용한 뇌척수액 유출 복원술)

  • Baek, Kwangha;Kim, Jihyung;Moon, Youngmin;Kim, Chang-Hoon;Yoon, Joo-Heon;Cho, Hyung-Ju
    • Journal of Rhinology
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2018
  • Background and Objectives: Endoscopic repair of cerebrospinal fluid (CSF) leak can avoid morbidity of open approaches and has shown a favorable success rate. Free mucosal graft is a good method, and multi-layered repair is more favorable. The inferior turbinate has been commonly utilized for the free mucosal graft, but we newly designed it as a bone-periosteal-mucosal composite graft for multilayered reconstruction. Subjects and Method: Four subjects with a skull base defect were treated with this method. The inferior turbinate was partially resected including the conchal bone and was trimmed according to defect size. Both bony parts and periosteum were preserved on the basolateral side of the mucosa as a composite graft. The graft was applied to the defect site using an overlay technique. Results: All cases were successfully repaired without any complications. Three of them had a defect size greater than 10-12 mm, and the graft stably repaired the CSF leakage. Conclusion: Endoscopic repair of CSF leakage using inferior turbinate composite graft is a simple and easy method and would be favorable for defect sizes greater than 10 mm.

Effects of hyperbaric oxygen on graft survival outcomes in composite grafting for amputated fingertip injury

  • Lee, Yoonsuk;Heo, Jae Won;Moon, Jin Sil;Kim, Sug Won;Kim, Jiye
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.444-450
    • /
    • 2020
  • Background Fingertip injuries are the most common type of traumatic injury treated at emergency departments and require prompt and adequate interventions for favorable wound survival outcomes. Hyperbaric oxygen (HBO2) therapy is well known for its many positive effects on wound healing. We hypothesized that treatment with HBO2 would improve the graft survival outcomes of amputated fingertip injuries treated with composite grafts. Methods This retrospective observational study included fingertip amputations that were treated between January 2013 and December 2017. A conventional group and an HBO2 therapy group were statistically compared to evaluate the effect of HBO2 treatment. Graft survival was categorized as either success or failure. Results Among 55 cases (digits), 34 digits were conventionally treated, while 21 digits were treated with HBO2. No statistically significant differences were observed between the groups with regard to general characteristics. Among patients with guillotine-type injuries, the composite graft success rate was statistically significantly higher in the group that received HBO2 therapy than in the conventional group (P=0.0337). Overall, the HBO2 group also demonstrated a statistically significantly shorter healing time than the conventional group (P=0.0075). As such, HBO2 treatment facilitates composite graft survival in cases of fingertip injury. Conclusions HBO2 treatment was associated with an increased composite graft survival rate in guillotine-type fingertip injuries and reduced the time required for grafts to heal.

In-vivo Studies on Effect of Lipo-PGE1 on Neoangiogenesis of Composite Graft in a Rabbit Model (가토모델에서 Lipo-PGE1이 복합조직이식편의 미세혈관신생에 미치는 영향)

  • Park, Ji-Ung;Eo, Su-Rak;Cho, Sang-Hun;Choi, Jong-Sun;Kim, Eo-Jin
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.721-725
    • /
    • 2010
  • Purpose: The survival of composite graft is dependent on three steps, (1) plasmatic imbibitions, (2) inosculation, and (3) neovascularization. Among the many trials to increase the survival rate of composite graft, prostaglandin E1 (PGE1) has beneficial effects on the microcirculatory level with vasodilating, antithrombotic, anti-inflammatory and neoangiogenic properties. Lipo-PGE1 which is lipid microspheres containing PGE1 had developed to compensate the systemic and local side effects of PGE1. This study was proposed to determine whether Lipo-PGE1 administration enhanced the survival of composite graft through neovascularization quantitatively in a rabbit ear model. Methods: Fourteen New Zealand White Rabbits each weighing 3~4 kg were divided in two groups: (1) intravenous Lipo-PGE1 injection group and (2) control group. A $2{\times}1\;cm$ sized, full-thickness rectangular composite graft was harvested in each auricle. Then, the graft was reaaproximated in situ using a 5-0 nylon suture. For the experimental group, $3{\mu}g$/kg/day of Lipo-PGE1 ($5{\mu}g$/mL) was administered intravenously through the marginal vein of the ear for 14 days. The control group was received no pharmacologic treatment. On the 14th postoperative day, composite graft of the ear was harvested and immunochemistry staining used Monoclonal mouse anti-CD 31 antibody was performed. Neoangiogenesis was quantified by counting the vessels that showed luminal structures surrounded by the brown color-stained epithelium and counted from 10 random high-power fields (400x) by independent blinded observer. Statistical analysis (Wilcoxon Signed Ranks test for nonparametric data) was performed using SPSS v12.0, with values of p<0.05 considered significant. Results: The mean number of the microvessels was $15.48{\pm}8.65$ in the experimental group and $9.82{\pm}7.25$ in the control group (p=0.028). Conclusion: The use of Lipo-PGE1 facilitated the neoangiogenesis, resulted in the improvement of the survival rate of graft. On the basis of this results, we could support wider application of Lipo-PGE1 for more effective therapeutic angiogenesis and successful survival in various cases of composite graft in the human.

Preparation and Characterization of PTMSP/PDMS-zeolite Composite Membranes for Gas Separation (기체분리를 위한 PTMSP/PDMS-zeolite 복합막의 제조 및 특성)

  • Kim, Na-Eun;Kang, Tae-Beom;Hong, Se Lyung
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.342-351
    • /
    • 2012
  • In this study, PTMSP[poly(1-trimethylsilyl-1-propyne)]/PDMS[poly(dimethylsioxane)]-NaY zeolite and PTMSP/PDMS-NaA zeolite composite membranes were made to incorporate zeolite into PTMSP/PDMS graft copolymer in order to improve the selectivity and thermal stability, the drop of permeability by physical aging effect during long period of time for the PTMSP membrane. To investigate the physico-chemical characteristics of composite membranes, the analytical methods such as FT-IR, $^1H$-NMR, TGA, SEM, and GPC have been utilized. The gas permeability and selectivity properties of $H_2$ and $N_2$ were evaluated. The permeability of the PTMSP/PDMS-NaY zeolite and PTMSP/PDMS-NaA zeolite composite membranes than PTMSP/PDMS graft copolymer membrane increased, increased as zeolite content increased. On the contrary, the selectivity ($H_2/N_2$) of the composite membranes decreased as zeolite content increased. PTMSP/PDMS-NaA zeolite composite membrane showed better permeability and separation factor than PTMSP/PDMS-NaY zeolite composite membrane.