• Title/Summary/Keyword: component state test

Search Result 131, Processing Time 0.033 seconds

Experimental evaluation of an inertial mass damper and its analytical model for cable vibration mitigation

  • Lu, Lei;Fermandois, Gaston A.;Lu, Xilin;Spencer, Billie F. Jr.;Duan, Yuan-Feng;Zhou, Ying
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.589-613
    • /
    • 2019
  • Cables are prone to vibration due to their low inherent damping characteristics. Recently, negative stiffness dampers have gained attentions, because of their promising energy dissipation ability. The viscous inertial mass damper (termed as VIMD hereinafter) can be viewed as one realization of the inerter. It is formed by paralleling an inertial mass part with a common energy dissipation element (e.g., viscous element) and able to provide pseudo-negative stiffness properties to flexible systems such as cables. A previous study examined the potential of IMD to enhance the damping of stay cables. Because there are already models for common energy dissipation elements, the key to establish a general model for IMD is to propose an analytical model of the rotary mass component. In this paper, the characteristics of the rotary mass and the proposed analytical model have been evaluated by the numerical and experimental tests. First, a series of harmonic tests are conducted to show the performance and properties of the IMD only having the rotary mass. Then, the mechanism of nonlinearities is analyzed, and an analytical model is introduced and validated by comparing with the experimental data. Finally, a real-time hybrid simulation test is conducted with a physical IMD specimen and cable numerical substructure under distributed sinusoidal excitation. The results show that the chosen model of the rotary mass part can provide better estimation on the damper's performance, and it is better to use it to form a general analytical model of IMD. On the other hand, the simplified damper model is accurate for the preliminary simulation of the cable responses.

Modeling of Hydrodynamic Processes at a Large Leak of Water into Sodium in the Fast Reactor Coolant Circuit

  • Perevoznikov, Sergey;Shvetsov, Yuriy;Kamayev, Aleksey;Pakhomov, Ilia;Borisov, Viacheslav;Pazin, Gennadiy;Mirzeabasov, Oleg;Korzun, Olga
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1162-1173
    • /
    • 2016
  • In this paper, we describe a physicomathematical model of the processes that occur in a sodium circuit with a variable flow cross-section in the case of a water leak into sodium. The application area for this technique includes the possibility of analyzing consequences of this leak as applied to sodium-water steam generators in fast neutron reactors. Hydrodynamic processes that occur in sodium circuits in the event of a water leak are described within the framework of a one-dimensional thermally nonequilibrium three-component gas-liquid flow model (sodium-hydrogen-sodium hydroxide). Consideration is given to the results of a mathematical modeling of experiments involving steam injection into the sodium loop of a circulation test facility. That was done by means of the computer code in which the proposed model had been implemented.

Verification of the Reliability and Validity of the Short Form 36 Scale in Indonesian Middle-aged and Older Adults

  • Arovah, Novita Intan;Heesch, Kristiann C.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.53 no.3
    • /
    • pp.180-188
    • /
    • 2020
  • Objectives: The Short Form 36 (SF-36) questionnaire is increasingly being used to measure health-related quality of life (HRQoL) in Indonesia. However, evidence that it is valid for use in Indonesian adults is lacking. This study assessed the validity and reliability of the SF-36 in Indonesian middle-aged and older adults. Methods: Adults aged 46-81 years (n=206) in Yogyakarta, Indonesia completed the SF-36, another measure of HRQoL (the EuroQoL visual analogue scale [EQ-VAS]), and measures assessing their demographic characteristics. Fifty-four percent (n=121) completed the SF-36 measure again 1 week later. Confirmatory factor analysis was conducted to confirm the factor structure of the SF-36. Internal consistency reliability was estimated using Cronbach's alpha, and test-retest reliability was assessed using intraclass correlations. Convergent and discriminant validity were assessed by computing correlations among SF-36 subscales, between subscales and the 2 component scores, and between component scores and EQ-VAS scores. Results: Most scaling assumptions were met. The hypothetical factor structure fit the data poorly (root mean square error of approximation [RMSEA]=0.108) and modification was required for a good fit (RMSEA=0.060). Scores on all subscales demonstrated acceptable internal consistency (α>0.70) and test-retest reliability (r>0.70). Divergent validity was supported by weak to moderate interscale correlations (r=0.19 to 0.64). As expected, the 2 summary scores were moderately to strongly correlated with the EQ-VAS (r>0.60). Conclusions: The findings adequately support the use of SF-36 in Indonesian middle-aged and older adults, although the optimal algorithm for computing component scores in Indonesia warrants further investigation.

Force Test of the Linear Induction Motor for Magnetic Levitation Train (자기부상열차용 유도형 리니어 모터의 작용력 시험)

  • Jang, S.S.;Chang, K.W.;Lee, S.H.;Kim, B.S.;Sung, H.H.;Cho, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.611-613
    • /
    • 2001
  • In this paper, the force test of arch-type LIM is treated. The method of direct measurement is used load-cell on 3-component force guage. Indirect method is used search coil on LIM. PC-based data aquistion system include two method and measure the force in driving state. Measured data of direct and indirect method are analyzed and compared.

  • PDF

Load Control Device for VVVF Inverter Testing (인버터 시험을 위한 부하제어 장치)

  • Kim, Gil-Dong;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.675-679
    • /
    • 2007
  • The control method of programmable dynamometer for overall test of machine is to load reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for moter torque of programmable dynamometer. Therefore, this kind of system could not perform dynamic and nonlinear load. In this paper, the control method using the load torque observer without a measure for torque transducer is proposed. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

Durability Prediction of Door W/H System Using FEM Analysis (전면 도어 와이어하니스 시스템의 내구 수명 예측에 관한 연구)

  • Kim, Byeong Sam;Lim, Kwangkyu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.2
    • /
    • pp.51-56
    • /
    • 2013
  • In vehicle's door wiring harness (W/H) system is more toward to arrange a passenger compartment than a hinge and a weatherstrip. An opening/closing member of a vehicle is attached to a vehicle by a hinge in a manner enabling easy opening and closing of the opening/closing member. Such members include doors, such as side-doors and rear doors, and other opening/closing members, such as trunk lids. This article gives some insight into the dimensioning process, with special focus on large deflection analysis of wiring harness(W/H) in vehicle's door structures for durability problem. The Finite elements analysis for door wiring harness(W/H) is used for residual stresses and dimensional stability with bending flexible. Durability test data for slam test specimens were compared with the numerical predicted fatigue life for verification. The final testing of the component combines the effects of these microstructural features with the complex stress state arising from the combined service loading and residual stresses.

Improved Programmable-Dynamometer Control For Traction Drive System Testing (견인구동시스템 시험을 위한 개선된 프로그램어블 다이나모메터 제어)

  • Kim G.D;Hong J.S;Shin J.R;Lee W.D;Han S.Y
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.427-432
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

Programmable-Dynamometer Control For Traction Motor Testing (전동기 시험을 위한 프로그램어블 다이나오메터 제어)

  • Kim, G.D.;Hong, J.S.;Ahn, T.K.;Lee, H.Y.;Shin, J.R.;Han, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1108-1110
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

A Study of Built-In-Test Diagnosis Mistakes as a False Alarm Filter Useful Redundant Techniques for Built-in-Test Related System

  • Oh, Hyun Seung;Yoo, Wang Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.21 no.2
    • /
    • pp.1-16
    • /
    • 1993
  • Early generations of products had little to no inherent capability to test themselves. The technologies involved often required only visual inspection and limited probing to troubleshoot the system once it was turned over to maintenance personnel. However, as the complexity of military and commercial systems grew, symptoms of failure became less noticeable to the operator. Therefore, the procedure to access, inspect, repair and replace a component became complicated, the requirements for personnel skill and testing equipment increased. and it took too long of a time to maintain a system. Meanwhile, the need for availability became more mission-critical and maintenance become very expensive. The obvious solution was to design in-system circuits or devices to self-test the primary system, the Built-In-Test(BIT) was born. This approach has continued right on up through present systems and is an integral part of systems now being designed. The object of this paper is to present a state-of-the-art research for filtering out the BIT diagnosis mistakes using Bayesian analysis and develop the algorithm for Redundant systems with BIT to improve BIT diagnosis.

  • PDF

The Implementation of Probabilistic Security Analysis in Composite Power System Reliability (복합전력계통 신뢰도평가의 확률론적 안전도 도입)

  • Cha, Jun-Min;Kwon, Sae-Hyuk;Kim, Hyung-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.5
    • /
    • pp.185-190
    • /
    • 2006
  • The security analysis relates to the ability of the electric systems to survive sudden disturbances such as electric short circuits or unanticipated loss of system elements. It is composed of both steady state and dynamic security analyses, which are not two separate issues but should be considered together. In steady state security analysis including voltage security analysis, the analysis checks that the system is operated within security limits by OPF (optimal power flow) after the transition of a new operating point. On the other hand, dynamic security analysis deals that the transition will lead to an acceptable operating condition. Transient stability, which is the ability of power systems to maintain synchronism when subjected to a large disturbance, is a principal component in dynamic security analysis. Usually any loss of synchronism will cause additional outages. They make the present steady state analysis of the post-contingency condition inadequate for unstable cases. This is the reason of the need for dynamics of systems. Probabilistic criterion can be used to recognize the probabilistic nature of system components and shows the possibility of system security. A comprehensive conceptual framework for probabilistic static and dynamic assessment is presented in this paper. The simulation results of the Western System Coordinating Council (WSCC) system compare an analytical method with Monte-Carlo simulation (MCS). Also, a case study of the extended IEEE Reliability Test System (RTS) shows the efficiency of this approach.