• Title/Summary/Keyword: complex odor

Search Result 118, Processing Time 0.026 seconds

A Survey on Current State of Odor Emission and Control from Livestock Operations (축산농장의 악취 발생과 관리에 관한 실태조사)

  • Kim, Doo-Hwan;Lee, In-Bok;Choi, Dong-Yoon;Song, Jun-Ik;Jeon, Joong-Hwan;Ha, Duk-Min
    • Journal of Animal Environmental Science
    • /
    • v.19 no.2
    • /
    • pp.123-132
    • /
    • 2013
  • This survey was conducted to investigate the current state of odor emission and control from 48 site of Hanwoo, dairy, swine and poultry farms in Korea. On-site complex odors assessment by the method of 6 step direct sensory evaluation and ammonia concentrations by portable gas detector on the boundary line of farms were evaluated and detected as 1.11 & 2.78 ppm, 1.67 & 2.56 ppm, 1.91 & 2.89 ppm, 1.8 & 2.4 ppm and 1.33 & 2.33 ppm, respectively. Almost of Hanwoo, dairy and poultry farms were nothing the complaints occurred for the last 2 years, however as 60% of swine farms were suffered odor complain. All of livestock operations were used the additives for improving the farm environment and spent the considerable costs for odor reduction. There were several plans almost farms, as a fortify maintenance, keep clean, tree planting, expansion facilities for manure treatment or odor reduction.

Characterization of the Bacterial Community Associated with Methane and Odor in a Pilot-Scale Landfill Biocover under Moderately Thermophilic Conditions

  • Yang, Hyoju;Jung, Hyekyeng;Oh, Kyungcheol;Jeon, Jun-Min;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.6
    • /
    • pp.803-814
    • /
    • 2021
  • A pilot-scale biocover was constructed at a sanitary landfill and the mitigation of methane and odor compounds was compared between the summer and non-summer seasons. The average inlet methane concentrations were 22.0%, 16.3%, and 31.3%, and the outlet concentrations were 0.1%, 0.1%, and 0.2% during winter, spring, and summer, respectively. The odor removal efficiency was 98.0% during summer, compared to 96.6% and 99.6% during winter and spring, respectively. No deterioration in methane and odor removal performance was observed even when the internal temperature of the biocover increased to more than 40℃ at midday during summer. During summer, the packing material simultaneously degraded methane and dimethyl sulfide (DMS) under both moderately thermophilic (40-50℃) and mesophilic conditions (30℃). Hyphomicrobium and Brevibacillus, which can degrade methane and DMS at 40℃ and 50℃, were isolated. The diversity of the bacterial community in the biocover during summer did not decrease significantly compared to other seasons. The thermophilic environment of the biocover during summer promoted the growth of thermotolerant and thermophilic bacterial populations. In particular, the major methane-oxidizing species were Methylocaldum spp. during summer and Methylobacter spp. during the non-summer seasons. The performance of the biocover remained stable under moderately thermophilic conditions due to the replacement of the main species and the maintenance of bacterial diversity. The information obtained in this study could be used to design biological processes for methane and odor removal during summer and/or in subtropical countries.

Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants (생활폐기물 자동집하시설의 악취물질 배출특성)

  • Yoon, Yongkyeong;Kim, Daekeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.541-548
    • /
    • 2012
  • The objective of this study was to investigate emission characteristics of odorous compounds from the pneumatic waste collection plants (namely, A and B sites). The air samples were collected from each site, at a carrier gas inside the plant and an exhaust gas, to analyze complex odor and 22 odorous compounds. Ammonia, sulfur compounds, and acetaldehyde were the critical odorous components generated in the plants studied. Characteristics of odor at exhaust outlet varied according to the type of odor control engineering. In the analysis of the odor contribution degree of odor components based on odor threshold, site A shows that the odor contribution of dimethyl sulfide was found to be 26%, acetaldehyde 18%, and methyl mercaptan 14%. For site B, methyl mercaptan was 56% and both hydrogen sulfide and dimethyl sulfide were 15%.

Odor Modeling of acetaldehyde in Gumi National Industrial Complex (구미국가산업단지의 아세트알데히드 악취모델링)

  • Lee, Eun Ju;Akhtar, Muhammad Saeed;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.22-35
    • /
    • 2016
  • In this study CALPUFF modeling was performed to establish a correlation between regions of frequent civil odor complaints near Gumi national industrial complex and odor-emission facilities of synthetic fiber manufacturers in the same area as main acetaldehyde-emission point sources. As a result of the CALPUFF modeling, the maximum concentration of acetaldehyde in Gumi national industrial complex was reduced from O ($10^{-5}g/m^3$) to O ($10^{-6}g/m^3$) upon improving emission facilities of T company so that the maximum concentrations of acetaldehyde frequently appeared in complex 3. In addition, the predicted range of the maximum acetaldehyde concentration in Gumi national industrial complex was also improved in comparison with that prior to improving emission facilities of T company. These maximum concentrations of acetaldehyde obtained to estimate the expected contribution of total acetaldehyde point source by CALPUFF modeling showed the similar values to those measured in 'HAPs investigation in the region of Gumi-Daegu' and were consistent to the trend of civil odor complaints. Therefore, the expected contribution of total acetaldehyde point source was validated. The relative contribution of T company upon improving its emission facilities was predicted to be lowered by more than factor of two, compared to that prior to improving its emission facilities. To the contrary, the relative contribution of W company upon improving emission facilities of T company was predicted to be increased by more than factor of two, compared to that prior to improving emission facilities of T company. This indicates that the contribution of aldehyde point sources of W company was relatively increased upon improving emission facilities of T company.

Impact Analysis of Complex Odor from Pigsty by Using ISCST3 (ISCST3을 이용한 돈사의 복합악취 영향 분석)

  • Kwon, Woo-Taeg;Hong, Sang-Pyo;Lee, Woo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6602-6609
    • /
    • 2013
  • This study is expected to provide background data for establishing mitigation measures for malodor and for comparing complex odor criteria. The impact of malodor at the afflicted locations was analyzed using Industrial Source Complex Short Term 3 (ISCST3) model, which was recommended by the EPA. The Odor Emission Rates (ODR) for piglets and hogs were predicted based on the average, minimum, and maximum emission rates as classification. The forecasting result of the complex odor modelling of pigsty showed that tolerance limit was exceeded at an adjacent administration building, but tolerance limit was not surpassed at an afflicted location which was within 185m from the pigsty. The ISCST3 modelling of the satisfactory ODR for tolerance limit was accomplished at the administration building. From the prediction of this modelling, maximum emission rates based on 1hr at administration building were 10.59~52.93, 19.05~31.76, and 10.59 $OU/m^3/s/m^2$ at emission rates of 50%, 30%, and 10%. This emission rate was slightly higher than the tolerance limit of 10.00 $OU/m^3/s/m^2$. However, it was inferred that the tolerance limit could be satisfied if the emission rate of 10% was controlled.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

Analysis of Field Measured Odor Emission Rate in Pig Houses (국내 돈사 악취 방출량 측정 결과 분석)

  • Decano-Valentin, Cristina;Lee, In-bok;Yeo, Uk-hyeon;Jeong, Duek-young;Lee, Sang-yeon;Park, Se-jun;Cho, Jeong-hwa;Lee, Min-hyeong;Jeong, Hyohyeog;Kim, Da-in;Kang, Sol-moe
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.55-63
    • /
    • 2022
  • Odors emitted from pig houses have been a constant root of legal issues in pig farming. These gases are among the main causes of health and mental stresses to nearby communities, so policymakers and researchers continuously study to reduce the concentration of odorous gases from pig facilities. A continuous field experiment proved that the concentration of odor emissions inside the pig houses is highly dependent on ventilation rate, breeding details, and animal activities. However, the standard odor emission rate worldwide widely varies due to differences in pig house designs and ventilation requirements. Thus, this study aimed to measure the odor emission rates, considering the actual condition of selected Korean pig houses, through field measurement. The odor measurements were performed at three different pig production facilities without odor abatement technologies. The target experimental pig houses were buildings for weaning, growing, and fattening pigs. Results showed that the actual ventilation rate in target pig houses falls below the standard ventilation requirement of pigs, resulting in high odor concentrations inside the pig houses.

Removal Efficiency of the Deodorization Equipment and Characteristics of Malodor during the Process in Co-treatment of Sewage and Food Waste of Su-young Wastewater Treatment Plant in Busan (부산수영하수처리장 하수와 음식물쓰레기 병합처리 시 공정별 악취특성 및 후처리시설 효율평가)

  • Lee, Hyung-Don;Kang, Dae-Jong;Lee, Min-Ho;Kang, Dong-Hyo;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.379-389
    • /
    • 2012
  • Environmental issues are being paid more attention due to income growth, urban overcrowding, and population growth in Korea. Among the various environmental problems, odor damage is the one of the serious factors. To take example for food waste combination treatment in Su-young wastewater treatment plant in Busan, many complaints occurred because this plant locate around residential areas. The purpose of this work is not only to analyze odorous elements and their contributions but also to evaluate odor quotient (OQ), sum of odor quotient (SOQ), and treatment efficiency of bio-filter. The results of dilution sensory test of complex odor, grinder, leachate, hopper indicated higher order complex odors happen in July and August. The main odorous elements consisted of hydrogen sulfide, ammonia, methly mercaptan and acetaldehyde, which were analyzed by instrumental detection method, and methyl mercaptan was exceeded over 3,571 times of threshold. In addition, result of contribution of odor was methyl mercaptan (49.95 to 59.08%), hydrogen sulfide (20.43 to 29.27%), trimethylamine (8.82 to 13.42%) and acetaldehyde (9.17 to 11.35%). Other facilities were compared with the contribution of the odor using OQ and SOQ during the process. Sulfur compounds, acetaldehyde, and trimethylamine are high contribution of odor using OQ as well as odor intensity of grinding process is highest. As a result, sulfur compounds (e.g., methyl mercaptan and hydrogen sulfide) are highest for OQ and SOQ of grinding process is highest as 7,067. The removal efficiency of deodorization equipment was more than 90.00% in ammonia and amines, but the average efficiency of sulfur compounds was 53.51%. Thus, this facility is more higher contribution of acetaldehyde and trimethylamine than other treatment facilities. And food waste treatment in environmental area needs to consider appropriate capacity and refers to other bio-filter operating conditions.

Dispersion Characteristics of Odorous Elements from Nambu Wastewater Treatment Plant and a Nearby Streams in Busan (부산시 남부하수처리시설과 인근 하천에서 발생하는 악취물질 확산 특성)

  • Mun, Seong-Man;Lee, Hyung-Don;Cho, Sang-Won;Kang, Dong-Hyo;Park, Hae-Sik;Oh, Kwang-Joong
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.953-962
    • /
    • 2011
  • The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.