• 제목/요약/키워드: complex modes

검색결과 402건 처리시간 0.032초

적합직교모드를 이용한 동적모드 AFM 의 비선형 모델링 (Nonlinear Modeling of Dynamic AFM Using Proper Orthogonal Modes)

  • 홍상혁;이수일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.379-382
    • /
    • 2007
  • The proper orthogonal decomposition(POD) is used to the modal analysis of microcantilever of dynamic mode atomic force microscopy(AFM). The proper orthogonal modes(POM) are extracted from vibrating signals of microcantilever when it resonates and taps the sample. The POMs resemble the linear normal modes(LNM) of cantilever vibrating at each resonance frequency. Some of POMs in tapping microcantilever show quite different shapes from the POMs of the resonating microcantilever. Also this POMs can be applied to model for the complex nonlinear behavior of the dynamic mode AFM microcantilevers.

  • PDF

Investigation on efficiency and applicability of subspace iteration method with accelerated starting vectors for calculating natural modes of structures

  • Kim, B.W.;Jung, H.J.;Hong, S.Y.
    • Structural Engineering and Mechanics
    • /
    • 제37권5호
    • /
    • pp.561-573
    • /
    • 2011
  • For efficient calculation of natural modes of structures, a numerical scheme which accelerates convergence of the subspace iteration method by employing accelerated starting Lanczos vectors was proposed in 2005. This paper is an extension of the study. The previous study simply showed feasibility of the proposed method by analyzing structures with smaller degrees of freedom. While, the present study verifies efficiency of the proposed method more rigorously by comparing closeness of conventional and accelerated starting vectors to genuine eigenvectors. This study also analyzes an example structure with larger degrees of freedom and more complex constraints in order to investigate applicability of the proposed method.

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1033-1036
    • /
    • 1998
  • In this research project, two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

고층 타워에 작용하는 동적 풍압력의 POD 방법을 이용한 시공간적 특성 해석 (Proper Orthogonal Decomposition Analysis of Dynamic Wind Pressures Acting on a Tall Tower Model)

  • 이미화;함희정
    • 산업기술연구
    • /
    • 제24권B호
    • /
    • pp.29-36
    • /
    • 2004
  • The wind and wind-induced dynamic wind pressures fluctuate irregularly according to time and space. In this study, the proper orthogonal decomposition(POD) technique is applied to wind pressures acting on a tall tower model, and the following results are found: the along-wind and across-wind forces can be reconstructed by only four dominant POD modes, and the reconstructed errors are 4.71% and 22%, respectively for across-wind and along-wind directions. The physical meanings for dominant modes are also presented in the paper. The POD analysis can compress complex wind pressure data only by a few dominant modes and interpret spatio-temporal characteristics of wind pressure by novel way while existing statistical methods do not have such benefits.

  • PDF

음향공명기가 장착된 가스터빈 연소실의 음향장 해석 (A Numerical Study on Acoustic Behavior in Gas Turbine Combustor with Acoustic Resonator)

  • 박이선;손채훈
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.95-102
    • /
    • 2005
  • Acoustic behavior in gas turbine combustor with acoustic resonator is investigated numerically by adopting linear acoustic analysis. Helmholtz-type resonator is employed as acoustic resonator to suppress acoustic instability passively. The tuning frequency of acoustic resonator is adjusted by varying its length. Through harmonic analysis, acoustic-pressure responses of chamber to acoustic excitation are obtained and the resonant acoustic modes are identified. Acoustic damping effect of acoustic resonator is quantified by damping factor. As the tuning frequency of acoustic resonator approaches the target frequency of the resonant mode to be suppressed. mode split from the original resonant mode to lower and upper modes appears and thereby complex patterns of acoustic responses show up. Considering mode split and damping effect as a function of tuning frequency, it is desirable to make acoustic resonator tuned to broad-band frequencies near the maximum frequency of those of the possible upper modes.

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.685-688
    • /
    • 1998
  • In this research project, two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

3차원 Floquet 안정성 분석을 위한 가상 경계법의 적용 (APPLICATION OF AN IMMERSED BOUNDARY METHOD FOR THREE-DIMENSIONAL FLOQUET STABILITY ANALYSIS)

  • 윤동혁;양경수
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.41-47
    • /
    • 2009
  • An immersed boundary method(IBM, Kim et al.(2001)) for simulating flows over complex geometries is applied to computation of three-dimensional Floquet stability of a periodic wake. Floquet stability analysis is employed to extract different modes of three-dimensional instability. To verify the present method, a fully-resolved Floquet stability calculation for flow past a circular cylinder is considered. There are two different instability modes with long(mode A) and short (mode B) spanwise wavelengths for the periodic wake of a circular cylinder. The critical Reynolds number and the most unstable spanwise wavelengths of modes A and B are computed using the present method, and compared with other authors' results currently available.

High-order, closely-spaced modal parameter estimation using wavelet analysis

  • Le, Thai-Hoa;Caracoglia, Luca
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.423-442
    • /
    • 2015
  • This study examines the wavelet transform for output-only system identification of ambient excited engineering structures with emphasis on its utilization for modal parameter estimation of high-order and closely-spaced modes. Sophisticated time-frequency resolution analysis has been carried out by employing the modified complex Morlet wavelet function for better adaption and flexibility of the time-frequency resolution to extract two closely-spaced frequencies. Furthermore, bandwidth refinement techniques such as a bandwidth resolution adaptation, a broadband filtering technique and a narrowband filtering one have been proposed in the study for the special treatments of high-order and closely-spaced modal parameter estimation. Ambient responses of a 5-story steel frame building have been used in the numerical example, using the proposed bandwidth refinement techniques, for estimating the modal parameters of the high-order and closely-spaced modes. The first five natural frequencies and damping ratios of the structure have been estimated; furthermore, the comparison among the various proposed bandwidth refinement techniques has also been examined.

계통의 종합적 미소신호 안정도해석에 관한 연구 (A Study on Integrated Small Signal Stability Analysis of Power Systems)

  • 남해곤;송성근;김용구;심관식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.365-368
    • /
    • 1998
  • In this research project two aspects of small signal stability are studied: improvement in Hessenberg method to compute the dominant electromechanical oscillation modes and siting FACTS devices to damp the low frequency oscillation. Fourier transform of transient stability simulation results identifies the frequencies of the dominant oscillation modes accurately. Inverse transformation of the state matrix with complex shift equal to the angular speed determined by Fourier transform enhances the ability of Hessenberg method to compute the dominant modes with good selectivity and small size of Hessenberg matrix. Any specified convergence tolerance is achieved using the iterative scheme of Hessenberg method. Siting FACTS devices such as SVC, STACOM, TCSC, TCPR and UPFC has been studied using the eigen-sensitivity theory of augmented matrix. Application results of the improved Hessenberg method and eigen-sensitivity to New England 10-machine 39-bus and KEPCO systems are presented.

  • PDF

복합유성기어장치를 적용한 플러그 방식 출입문의 변속장치 (Complex Planetary Gear Train for a Plug type Passenger Door)

  • 김연수;홍재성;박성혁;백남욱;이병송
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.170-177
    • /
    • 2001
  • Since plug type passenger door has two motion modes, power transmission unit must be capable of plug-in or plug-out, and sliding mode. Complex planetary gear train is proposed, which is composed of two 2K-H, I type planetary gear units. For the proposed complex planetary gear train, ranges of addendum modification coefficients which would not lead to interferences is analyzed, and optimal addendum modification coefficients among these ranges which generate the maximum efficiency are presented. Based on the interference, efficiency and torque ratio analysis results, complex planetary new train is designed and manufactured.