• 제목/요약/키워드: complex mode

Search Result 860, Processing Time 0.023 seconds

Fast Coding Mode Decision for H.264 Video Coding (H.264 동영상 압축을 위한 고속 부호화 모드 결정 방법)

  • 이제윤;전병우
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.165-173
    • /
    • 2004
  • H.264 is the newest international video coding standard that provides high coding efficiency. A macroblock in H.264 has 7 different motion-compensation block sizes in the Inter mode, and several different prediction directions in the Intra mode. In order to achieve as highest coding efficiency as possible, H.264 reference model employs complex mode decision technique based on rate-distortion (RD) optimization which requires high computational complexity. In this paper, we propose two techniques -'early SKIP mode decision' and 'selective intra mode decision' - which can further reduce the computational complexity. Simulation results show that without considerable performance degradation, the proposed methods reduce encoding time by 30% on average and save the number of computing rate-distortion cost by 72%.

Fatigue Crack Closure and Propagation Behavior Under Mixed-Mode Loading Observed by the Direct Measuring Method (직접측정법을 이용한 혼합모드 하중 하에서 피로균열의 닫힘과 전파거동)

  • Song Sam Hong;Seo Ki Jeong;Lee Jeong Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.152-158
    • /
    • 2005
  • The stress conditions acting on the practical structure are complex, and thus most cracks existing in the practical structures are under mixed-mode loading conditions. The effect of shear load component of mixed-mode loading acts more greatly in the stage of crack initiation and initial propagation than crack propagation stage. Hence, research on the behavior in the stage of crack initiation and initial propagation need to be examined in order to evaluate behavior of mixed-mode fatigue cracks. In this study, the crack tip displacement(CTD) was measured by using the direct measuring method(DMM). We examined the behavior at crack tip by determining crack opening load$(P_{op})$. From the test results, the propagation behavior of mixed-mode fatigue cracks was evaluated by considering mixed-mode crack closure. Also, we examined the characteristic of crack propagation under mixed-mode loading with crack propagation direction.

Design of Sliding Mode Controller with Auto-tuning Method

  • He, Wei;Zhai, Yujia
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.2
    • /
    • pp.43-50
    • /
    • 2013
  • Sliding mode control(SMC) are carried out in this literature. And to make the controllers perform better, fuzzy logic was chosen,it makes PID controller auto-tuning parameters and reduced the chattering problem of sliding mode control. Since SMC take error and derivative of error as inputs, after comparison some results are obtained.PID controller response faster yet sliding mode control is much steadier. However certain problems cannot be ignored that the chattering phenomenal cannot be reduced entirely and this motion may hurt the machine; this project only considered a simple system, there is no guarantee PID can work as well as in this case for a much more complex system. MATLAB simulink was the main approach to obtain the performance of the two controllers: to observe the control output of the two controllers, electric circuit and special controllers are designed and tested in MATLAB.

Finite-Time Convergent Guidance Law Based on Second-Order Sliding Mode Control Theory

  • Ji, Yi;Lin, Defu;Wang, Wei;Lin, Shiyao
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.697-708
    • /
    • 2017
  • The complex battlefield environment makes it difficult to intercept maneuvering targets for guided missiles. In this paper, a finite-time convergent (FTC) guidance law based on the second-order sliding mode (SOSM) control theory is proposed to achieve the requirements of stability, accuracy and robustness. More specifically, a second-order sliding mode observer (SMOB) is used to estimate and compensate for the total disturbance of the controlled system, while the target acceleration is extracted from the line-of-sight (LOS) angle measurement. The proposed guidance law can drive the LOS angular rate converge to zero in a finite time, which means that the missile will accurately intercept the target. Numerical simulations with some comparisons are performed to demonstrate the superiority of the proposed guidance law.

Evaluation of the Image Backtrack-Based Fast Direct Mode Decision Algorithm

  • Choi, Yungho;Park, Neungsoo
    • Journal of Information Processing Systems
    • /
    • v.8 no.4
    • /
    • pp.685-692
    • /
    • 2012
  • B frame bi-directional predictions and the DIRECT mode coding of the H.264 video compression standard necessitate a complex mode decision process, resulting in a long computation time. To make H.264 feasible, this paper proposes an image backtrack-based fast (IBFD) algorithm and evaluates the performances of two promising fast algorithms (i.e., AFDM and IBFD). Evaluation results show that an image backtrack-based fast (IBFD) algorithm can determine DIRECT mode macroblocks with 13% higher accuracy, as compared with the AFDM. Furthermore, IBFD is shown to reduce the motion estimation time of B frames by up to 23% with a negligible quality degradation.

Comparison of the Binding Modes of [Ru(2,2'-bipyridine)3]2+ and [Ru(2,2':6',2"-terpyridine)2]2+ to Native DNA

  • Jang, Yoon-Jung;Lee, Hyun-Mee;Jang, Kyeung-Joo;Lee, Jae-Cheol;Kim, Seog-K.;Cho, Tae-Sub
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1314-1318
    • /
    • 2010
  • The $[Ru(tpy)_2]Cl_2$ (tpy:2,2':6',2"-terpyridine) complex was synthesized and its structure was confirmed by $^1H$-NMR and elemental analysis. Its binding mode toward DNA was compared with the well-known $[Ru(bpy)_3]Cl_2$ (bpy:2,2-bipyridyl), using isotropic absorption, linear dichroism(LD) spectroscopy, and an energy minimization study. Compared to $[Ru(bpy)_3]^{2+}$, the $[Ru(tpy)_2]^{2+}$ complex exhibited very little change in its absorption pattern, especially in the MLCT band, upon binding to DNA. Furthermore, upon DNA binding, both Ru(II) complexes induced a decrease in the LD magnitude in the DNA absorption region. The $[Ru(tpy)_2]^{2+}$ complex produced a strong positive LD signal in the ligand absorption region, which is in contrast with the $[Ru(bpy)_3]^{2+}$ complex. Observed spectral properties led to the conclusion that the interaction between the ligands and DNA bases is negligible for the $[Ru(tpy)_2]^{2+}$ complex, although it formed an adduct with DNA. This conclusion implies that both complexes bind to the surface of DNA, most likely to negatively charged phosphate groups via a simple electrostatic interaction, thereby orienting to exhibit the LD signal. The energy minimization calculation also supported this conclusion.

Coordination Modes and Properties of Ag(I) Complex with N,N,N',N',N''-Pentamethyldiethylenetriamine

  • Chun, In-Sung;Kwon, Jung-Ah;Bae, Myung-Nam;Lee, Sim-Seong;Jung, Ok-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.7
    • /
    • pp.1005-1008
    • /
    • 2006
  • The reaction of $AgClO_{4}$ with acyclic potential tridentate N,N,N',N',N''-pentamethyldiethylenetriamine (pmdeta) has given colorless crystals suitable for X-ray crystallography. The crystal structure ($P2_{1}$/n, a = 14.413(1) $\AA$, b = 25.270(2) $\AA$, c = 16.130(1) $\AA$, b = $103.012(1){^{\circ}}$, V = 5723.7(8) A$\AA^{3}$, Z = 4, R = 0.0349) has been solved and refined. Three silver(I) ions connect four pmdeta ligands to produce discrete complex of $[Ag_3(pmdeta)_4](ClO_4)_3$. A pmdeta ligand is bridged to three silver(I) ions, and three other pmdeta ligands are chelated to each silver(I) center in a tridentate mode. Thus, the product is a rare tri-nuclear silver(I) complex with two different chemical environments. $^{13}C$ NMR and $MAS\;^{13}$C NMR indicate that the tri-nuclear silver(I) complex is not rigid in solution. The contact angles and thermal analyses of the complex are measured and discussed.

Dynamic Analysis of Offshore Structures by the Advanced Mode Acceleration Method (개선된 Mode Acceleration Method에 의한 해양(海洋) 구조물(構造物)의 동적(動的) 해석(解析))

  • Kim, Tae Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 1994
  • Determination of the number of modes to be included in the mode superposition method(MSM) is very important and difficult. Mode acceleration method(MAM) is recommended recently with the intention to overcome the problem. But the solution of the MAM is complex and complicate in frequency domain analysis. In this paper, advanced mode acceleration method(AMAM) is formulated and examined. The results from example analyses show that AMAM is a simple, accurate and reliable method compared with the MSM and the MAM.

  • PDF

Comparison of Learning Effects using High-fidelity and Multi-mode Simulation: An Application of Emergency Care for a Patient with Cardiac Arrest (High-fidelity와 Multi-mode 시뮬레이션을 이용한 학습 효과 비교 : 심정지 환자 응급간호 적용)

  • Ryoo, Eon-Na;Ha, Eun-Ho;Cho, Jin-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.2
    • /
    • pp.185-193
    • /
    • 2013
  • Purpose: Simulation-based learning has become a powerful method to improve the quality of care and help students meet the challenges of increasingly complex clinical practice settings. The purpose of this study was to identify the learning effects using high-fidelity SimMan and multi-mode simulation. Methods: Participants in this study were 38 students who were enrolled in an intensive course for a major in nursing at R college. Collected data were analyzed using Chi-square, t-test, and independent t-test with the SPSS 18.0 for Windows Program. Results: There were no statistically significant differences in learning effects between high-fidelity SimMan and multi-mode simulation group. However, skills in clinical performance in the high-fidelity SimMan group were higher than in the multi-mode group (p=.014), communication in clinical performance in multi-mode simulation group was higher than in the high-fidelity SimMan group (p<.001). Conclusion: Multi-mode simulation with a standardized patient is an effective learning method in many ways compared to a high-fidelity simulator. These results suggest that multi-mode simulation be offered to students in nursing colleges which cannot afford to purchase a high-fidelity simulator, or offered as an alternative.

Determination of Plane-wave Reflection Coefficient in Underwater Acoustic Pulse Tube Using Two-dimensional Fourier Filtering (이차원 푸리에 필터링을 이용한 수중음향 펄스 튜브에서의 평면파 반사계수 결정)

  • Kim, Wan-Gu;Kang, Hwi Suk;Yoon, Suk Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.493-498
    • /
    • 2015
  • Complex acoustic signals can be formed in a water-filled acoustic pulse tube under some exciting conditions. It makes difficult to measure plane-wave reflection coefficient with the pulse tube for low frequency bands. In this study, using COMSOL Multiphysics we show that the tube wall excitation generates complex acoustic field of nonplanar mode as well as planar one. From such field incident or reflected planar mode can be decomposed respectively with a modal decomposition method, two-dimensional Fourier filtering. It makes possible to more accurately determine the plane-wave reflection coefficient of acoustic specimen with time gating.