• Title/Summary/Keyword: competitive Langmuir isotherm

Search Result 15, Processing Time 0.02 seconds

Separation of Amino Acids by Simulated Moving Bed Using Competitive Langmuir Isotherm

  • Yang, Yun-Jeong;Lee, Chong-Ho;Koo, Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.331-338
    • /
    • 2004
  • The Separation of two amino acids, phenylalanine and tryptophan, was carried out using laboratory simulated moving bed (SMB) chromatography. The SMB process consisted of four zones, with each zone having 2 columns. The triangle theory was used to obtain the operating conditions for the SMB. The mass transfer coefficients of the two amino acids were obtained from the best-fit values by comparing simulated and experimental pulse data. The competitive adsorption isotherms of the two amino acids were obtained by single and binary frontal analyses, taking into consideration the competition between the two components. A competitive Langmuir isotherm, obtained from single-component frontal chromatography, was used in the first run, and the isotherm from binary frontal chromatography in the second, with the flow rate of zone 1 modified to improve the purity. Compared to the first and second runs, the competitive Langmuir isotherm from the binary frontal chromatography Showed good agreement with the experimental results. Also, adjusting the flow rate in zone 1 increased the purity of the products. The purities of the phenylalanine in the raffinate and the tryptophan in the extract were 99.84 and $99.99\%$, respectively.

Sensitivity Analysis of Amino Acids in Simulated Moving Bed Chromatography

  • Lee, Ju-Weon;Lee, Chong-Ho;Koo, Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.2
    • /
    • pp.110-115
    • /
    • 2006
  • We conducted a sensitivity analysis of the simulated moving bed (SMB) chromatography with the case model of the separation of two amino acids phenylalanine and tryptophan. We consider a four-zone SMB chromatography where the triangle theory is used to determine the operating conditions. Competitive Langmuir isotherm model was used to determine the adsorption isotherm. The finite difference method is used to solve nonlinear partial differential equation (PDE) systems numerically. We examined the effects of alterations in the operating conditions(feed-extract, feed-raffinate, eluent-extract, eluent-raffinate, recycle, and switching time) and the adsorption isotherm parameters (Langmuir isotherm parameters a and b) on SMB efficiency. The variation range of operating conditions and Langmuir isotherm a was between -50 and 50% of original value and the variation range of the Langmuir isotherm b was between $2.25^{-5}$ and $2.25^5$ times of original value.

Nonlinear Adsorption Isotherm of Single and Multi-Components of 2'-Deoxyribonucleosides (2'-deoxyribonucleosides의 단일 및 다성분계의 비선형 흡착평형식)

  • Jin, Long Mei;Han, Soon Koo;Choi, Dae-Ki;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.230-235
    • /
    • 2005
  • Reversed-phase high-performance liquid chromatography (RP-HPLC) was used to determine the equilibrium isotherm of single and multi-components of dUrd(2'-deoxyuridine), dGuo(2'-deoxyguanosine), and dAdo(2'-deoxyadenosine) of 2'-deoxyribonucleosides by dynamic method. The composition of mobile phase was 90/10 vol.% (water/MeOH). With an increase in the injection volumes, the retention times were shorter and the peak shapes were triangle-shaped, so Langmuir-type isotherm was assumed. The Langmuir adsorption parameters were estimated by PIM (pulsed-input method), and the competitive Langmuir adsorption isotherm was further utilized. For the sample of the dUrd and dGuo whose retention times were relatively short, the agreement of between the calculated value and experimental data was fairly good in both single and multi-components, but for the dAdo, the last eluting component, some deviations were caused by non-linear and non-ideal properties.

Evaluation of NH4+-N Ion Exchange Property using Natural Zeolite and Zeolite Carrier (천연 제올라이트와 제올라이트 담체를 이용한 NH4+-N 이온교환 특성 평가)

  • Lee, Kwang Hyun;Park, Min Suk;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.750-757
    • /
    • 2009
  • The ammonium ion exchange characteristics of natural zeolite were investigated to remove ${NH_4}^+-N$. The effect of water temperature, particle size and competitive cation on the exchange capacity was examined. Ammonium ion exchange capacity tended to decrease when the temperature increased from $25^{\circ}C$ to $40^{\circ}C$. Exchange capacity was increased according to the particle size of natural zeolite comes to be small. Batch isotherm experiments were conducted for measuring ammonium ion exchange capacity. The ion exchange capacity was well described either by the Langmuir isotherm model or by the Freundlich isotherm model. The ammonium ion exchange capacity ($q_m$) of zeolite carrier can be calculated $11.744mg-{NH_4}^+/g$-carrier. The ion exchange capacity of manufactured zeolite carrier was showed a similar tendency as ion exchange capacity of powder-sized natural zeolite. Therefore, zeolite carrier can be used for increasing of nitrogen removal efficiency in the wastewater treatment plants.

Isotherm, Kinetic, Thermodynamic and Competitive for Adsorption of Brilliant Green and Quinoline Yellow Dyes by Activated Carbon (활성탄에 의한 Brilliant Green과 Quinoline Yellow 염료의 흡착에 대한 등온선, 동력학, 열역학 및 경쟁흡착)

  • Lee, Jong Jib
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.565-573
    • /
    • 2021
  • Isotherms, kinetics and thermodynamic properties for adsorption of Brilliant Green(BG), Quinoline Yellow(QY) dyes by activated carbon were carried out using variables such as dose of adsorbent, pH, initial concentration, contact time, temperature and competitive. BG showed the highest adsorption rate of 92.4% at pH 11, and QY was adsorbed at 90.9% at pH 3. BG was in good agreement with the Freundlich isothermal model, and QY was well matched with Langmuir model. The separation coefficients of isotherm model indicated that these dyes could be effectively treated by activated carbon. Estimated adsorption energy by Temkin isotherm model indicated that the adsorption of BG and QY by activated carbon is a physical adsorption. The kinetic experimental results showed that the pseudo second order model had a better fit than the pseudo first order model with a smaller in the equilibrium adsorption amount. It was confirmed that surface diffusion was a rate controlling step by the intraparticle diffusion model. The activation energy and enthalpy change of the adsorption process indicated that the adsorption process was a relatively easy endothermic reaction. The entropy change indicated that the disorder of the adsorption system increased as the adsorption of BG and QY dyes to activated carbon proceeded. Gibbs free energy was found that the adsorption reaction became more spontaneous with increasing temperature. As a result of competitive adsorption of the mixed solution, it was found that QY was disturbed by BG and the adsorption reduced.

Competitive Adsorption in Binary Solution with Different Mole Ratio of Sr and Cs by Zeolite A : Adsorption Isotherm and Kinetics (스트론튬과 세슘 이온의 혼합 몰비를 달리한 이성분 용액에서 제올라이트 A에 의한 경쟁 흡착: 흡착등온 및 속도해석)

  • Lee, Chang-Han;Park, Jeong-Min;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.151-162
    • /
    • 2015
  • The adsorption characteristics of Sr ions and Cs ions in single and binary solution by zeolite A were investigated in batch experiment. The adsorption rate of Sr ions and Cs ions by zeolite A obeyed pseudo-second-order kinetic model in single and binary solution. The initial adsorption rates (h) and adsorption capacities of both ions obtained from pseudo-second-order kinetic model, and the values were decreased with increasing concentration of the competitive ions (0~1.5 mM). Also, adsorption isotherm data in binary solution were well fitted to the extended Langmuir model, the maximum adsorption capacities of Sr and Cs calculated from the model were 1.78 mmol/g and 1.64 mmol/g, respectively. The adsorption of Sr and Cs ions by zeolite A was carried out in the presence of other cations such as $Na^+$, $K^+$, $Mg^{2+}$ and $Ca^{2+}$. The results showed that the zeolite A can maintain a relatively high adsorption capacity for Sr and Cs ions and exhibits a high selectivity in the presence of competitive cations. The effect of competition had an order of $Ca^{2+}$ > $K^+$ > $Mg^{2+}$ > $Na^+$ for Sr ions and $K^+$ > $Ca^{2+}$ > $Na^+$ > $Mg^{2+}$ for Cs ions at the same cation concentration.

Adsorption of Dyes with Different Functional Group by Activated Carbon: Parameters and Competitive Adsorption (활성탄에 의한 작용기가 다른 염료의 흡착: 파라미터 및 경쟁 흡착)

  • Lee, Jong Jib
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.151-158
    • /
    • 2022
  • In this paper, parameter characteristics such as pH effect, isotherm, kinetic and thermodynamic parameters and competitive adsorption of dyes including malachite green (MG), direct red 81 (DR 81) and thioflavin S (TS), which have different functional groups, being adsorbed onto activated carbon were investigated. Langmuir, Freundlich and Temkin isotherm models were employed to find the adsorption mechanism. Effectiveness of adsorption treatment of three dyes by activated carbon were confirmed by the Langmuir dimensionless separation factor. The mechanism was found to be a physical adsorption which can be verified through the adsorption heat calculated by Temkin equation. The adsorption kinetics followed the pseudo second order and the rate limiting step was intra-particle diffusion. The positive enthalpy and entropy changes showed an endothermic reaction and increased disorder via adsorption at the S-L interface, respectively. For each dye molecule, negative Gibbs free energy increased with the temperature, which means that the process is spontaneous. In the binary component system, it was found that the same functional groups of the dye could interfere with the mutual adsorption, and different functional groups did not significantly affect the adsorption. In the ternary component system, the adsorption for MG lowered a bit, likely to be disturbed by the other dyes meanwhile DR 81 and TS were to be positively affected by the presence of MG, thus resulting in much higher adsorption.

Predictive Modeling of Competitive Biosorption Equilibrium Data

  • Chu K.H.;Kim E.Y.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.1
    • /
    • pp.67-71
    • /
    • 2006
  • This paper compares regression and neural network modeling approaches to predict competitive biosorption equilibrium data. The regression approach is based on the fitting of modified Langmuir-type isotherm models to experimental data. Neural networks, on the other hand, are non-parametric statistical estimators capable of identifying patterns in data and correlations between input and output. Our results show that the neural network approach outperforms traditional regression-based modeling in correlating and predicting the simultaneous uptake of copper and cadmium by a microbial biosorbent. The neural network is capable of accurately predicting unseen data when provided with limited amounts of data for training. Because neural networks are purely data-driven models, they are more suitable for obtaining accurate predictions than for probing the physical nature of the biosorption process.

Competitive Adsorption Characteristics of Rapid Cooling Slag in Single- and Multi-Metal Solutions (단일 및 복합중금속용액에서 제강급랭슬래그의 경쟁흡착특성)

  • Park, Jong-Hwan;Kim, Hong-Chul;Kim, Seong-Heon;Lee, Seong-Tae;Kang, Byung-Hwa;Kang, Se-Won;Seo, Dong-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.1
    • /
    • pp.24-31
    • /
    • 2016
  • BACKGROUND: Heavy metal adsorption not only depends on rapid cooling slag(RCS) characteristics but also on the nature of the metals involved and on their competitive behavior for RCS adsorption sites. The goal of this study was to investigate the competitive absorption characteristics of Cu, Cd and Zn in single- and multi-metal forms by RCS.METHODS AND RESULTS: Both single- and multi-metal adsorption experiments were conducted to determine the adsorption characteristics of RCS for the heavy metals. Adsorption behaviors of the heavy metals by RCS were evaluated using both the Freundlich and Langmuir adsorption isotherm equations. The maximum adsorption capacities of metals by RCS were in the order of Cu(16.6 mg/g) > Cd(8.1 mg/g) > Zn(6.2 mg/g) in the single-metal adsorption isotherm and Cu(14.5 mg/g) >> Zn(1.3 mg/g) > Cd(0.6 mg/g) in the multi-metal adsorption isotherm. Based on data obtained from Freundlich and Langmuir adsorption models and three-dimensional simulation, multi-metal adsorption behaviors differed from single- metal adsorption due to competition. Cadmium and Zn were easily exchanged and substituted by Cu during multi-metal adsorption.CONCLUSION: Results from adsorption experiments indicate that competitive adsorption among metals increases the mobility of these metals.

Experimental and FEMLAB Simulation Study of Ibuprofen Racemate Separation in HPLC (Ibuprofen Racemate의 HPLC 분리실험과 FEMLAB 전산모사 연구)

  • Lee, Eun;Chang, Sang-Mork;Kim, Jong-Min;Kim, Woo-Shick;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.224-229
    • /
    • 2006
  • FEMLAB is a powerful interactive environment for modeling, solving all kinds of scientific and engineering problems based on partial differential equations(PDEs). Separation process of chiral compound in HPLC columns was simulated by FEMLAB. To study change of elution profile with isotherm models, non-competitive and competitive Langmuir adsorption isotherm were adopted. Separated material was (R, S)-ibuprofen [(R, S)-2-(4-isobutyl phenyl) propionic acid], an anti-inflammatory agent, which retain the pharmacological activity in the (S)-(+)-enantiomer. Sample concentrations were changed from 0.5 mg/ml to 2.0 mg/ml at a flow rate of 1 ml/min and flow rate varied from 1 ml/min to 3 ml/min at an ibuprofen concentration of 2.0 mg/ml and $20{\mu}l$ of injection volume. Simulated results were well fitted with experimental data.