• Title/Summary/Keyword: compensator

Search Result 1,349, Processing Time 0.033 seconds

A Power Factor Compensator Using a Force-Commutated Cycloconverter (강제 전류 싸이크로 컨버터를 이용한 무효 전력 보상)

  • Jung, Yon-Tack;Seo, Young-Soo;Lim, Young-Bae;Kim, Soung-Gi;Hwang, Jun-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.770-772
    • /
    • 1993
  • This paper is a study of a reactive-power compensator. It make using Power-MOSFET that be little quantity driving-power, easy to control, and be passible to highspeed wich be capable to achieve a reactive power compensator, to get rid of harmonics. On account of having no particular control circuit, composing not need to energy storage element and feedback control compered the previous power transformer in the system organization. It efficiqntly ueed to be in power factor compensation variable load.

  • PDF

A Sensorless Speed Control of an Interior Permanent Magnet Synchronous Motor Based on a Fuzzy Speed Compensator (퍼지 속도 보상기를 이용한 매입형 영구자석 동기 전동기의 센서리스 속도제어)

  • Kang, Hyoung-Seok;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1405-1411
    • /
    • 2007
  • In this paper, a new speed sensorless control based on a fuzzy compensator are proposed for the interior permanent magnet synchronous motor (IPMSM) drives. The conventional proportional plus integrate(PI) control are very sensitive to step change of the command speed, parameter variations and load disturbance. To cope with these problems of the PI control, the estimated speeds are compensated by using the fuzzy logic controller (FLC). In the FLC used by the speed compensator of the IPMSM, the system control parameters are adjusted by the fuzzy rule based system, which is a logical model of the human behavior for process control. The effectiveness of algorithm is confirmed by the experiments.

A Speed Sensorless Vector Control of Interior Permanent Magnet Synchronous Motors Using a Fuzzy Speed Compensator (퍼지속도보상기를 이용한 매입형 영구자석 동기전동기의 속도 센서리스 제어)

  • Kim, Cheon-Kyu;Kim, Young-Jo;Lee, Eul-Jae;Choi, Jung-Soo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1114-1115
    • /
    • 2007
  • In this paper, a new speed sensorless control based on a fuzzy compensator are proposed for the interior permanent magnet synchronous motor (IPMSM) drives. The conventional proportional plus integrate(PI) control are very sensitive to step change of the command speed, parameter variations and load disturbance. To cope with these problems of the PI control, the estimated speeds are compensated by using the fuzzy logic controller (FLC). In the FLC used by the speed compensator of the IPMSM, the system control parameters are adjusted by the fuzzy rule based system, which is a logical model of the human behavior for process control. The effectiveness of algorithm is confirmed by the experiments.

  • PDF

A Control Algorithm Design for 45kVA UPQC Prototype (45kVA UPQC 제어 알고리즘 설계)

  • Jeon, Jin-Hong;Kim, Tae-Jin;Ryoo, Hong-Je;Ahn, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1483-1485
    • /
    • 2005
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality problems. As a series and shunt compensator, UPQC consists of two inverters with common dc link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present simulation and test result of developed UPQC system. Test for UPQC are performed at voltage sag, flickers and non-linear load conditions. For voltage sag and ficker generation, we use RTDS(Real Time Digital Simulator) and power amplifier system.

  • PDF

A Vibration Control of a Flexible Beam using a Nonlinear Compensator with Complex Dual-Input Describing Function (복소쌍입력 기술함수를 갖는 비선형 보상기를 이용한 유연한 빔의 진동제어)

  • 권세현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.227-235
    • /
    • 1999
  • In this paper a vibration control fo a one-link flexible beam is considered. At first a state-space model for a flexible beam is derived by using the assumed-modes approach. Based on this model the transfer function between the applied torque and the tip deflection fo the beam is presented because it is convenient to apply our method. In general there exist some control difference due to flexibility of the beam so we adop a forward-passive controller to reduce these phenomena. And a complex dual-input describing function compensator is used to control the tip deflection. The stabiltiy and the performance of the closed-loop system are analyzed. Finally the validity of the derived model and the effectiveness of proposed controller are confirmed throuth simula-tions and experiments.

  • PDF

Robust Control of a 6-Link Electro-Hydraulic Manipulator using Parallel Feed forward Compensator (PFC보상기를 응용한 6축 전기 유압매니퓰레이터의 강인 제어)

  • 안경관;정연오
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.89-96
    • /
    • 2003
  • An electro-hydraulic manipulator using hydraulic actuators has many nonlinear abetments, and its parameter fluctuations are greater than those of an electrically driven manipulator. So it is relatively difficult to realize not only stable but also accurate trajectory control for the autonomous assembly tasks using hydraulic manipulators. In this report, we propose a two-degree-of-freedom control including parallel feedforward compensator (PFC) where PFC plays a very important role in the stability of a proposed control system. In the experimental results of the 6-link electro hydraulic manipulator, it is verified that the stability and the model matching performance are improved by using the proposed control method.

Compensation Logics of Controller in Korean Standard Super Critical Once Through Boiler

  • Kim, Eun-Gee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.65.2-65
    • /
    • 2001
  • There are not only lots of controllers such as UMC(Unit Master Controller), BMC(Boiler Master Controller), Fuel Flow controller, Air flow controller, Feed water flow controller, S/H R/H Temperature controller and so on, but also compensation controller such as BTU compensator, Fuel/Water ratio controller and O2 Co controller to take automatic control in the super critical once through boiler. It is important to make complete automation of boiler to use the compensation controller like BTU compensator. For example, In case of some boiler condition, operator has to change combustion parameter for changing the coal, on the contrary BTU compensator can calculate set value of the fuel flow and reset the fuel flow demand by itself. This paper shows us the logic and instruction regarding compensation controller of boiler that can be operated automatically.

  • PDF

Consideration Regarding the Breast Cancer Treatment Plan That Used Irregular Surface Compensator (ISC) (Irregular Surface Compensator (ISC)를 이용한 유방암치료계획에 관한 고찰)

  • Je, Young-Wan;Kim, Chan-Yong;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.131-141
    • /
    • 2007
  • Purpose: Try to compare dose distribution and lung dose of radiation treatment plan of the breast cancer that used Irregular Surface Compensator (ISC) and treatment plan that used a wedge filter. Materials and Methods: Established a treatment plan to be distributed over 95% of prescription dose (5,040 cGy) of the two tangent-half fields that used a wedge filter and ISC at a breast organization as made to breast cancer patient having an irregular surfaces after surgery. Compared high dose area and DVH, and verified a treatment plan as used film with rectangular phantom. Results: Maximum dose point in breast tissue appeared to 107.5% in case of tangent-half fields Tx plan that used a wedge filter, and lung volumes exposed above 20 Gy by 7.63%. In case of ISC, maximum dose point in breast tissue appeared to 106.4%, and lung volumes exposed above 20 Gy by 6.5%. The film measurement results that used phantom, 105$\sim$110% high dose region was distributed to the upper part and both edges of phantom. However in case of ISC, appeared by 100$\sim$105% dose conformity distribution. Conclusion: In general, the Irregular Surface Compensator (ISC) can improve the dose conformity of breast tissues, as well as reduced hot spots in the lung and in the breast. Such an advantage by using ISC technique is more beneficial for patients who have more irregular surfaces after surgery.

  • PDF

Development of Total Body Irradiation Program (전신방사선조사 프로그램 개발)

  • Choi Byung Ock;Jang Ji Sun;Kang Young Nam;Choi Ihl Bohng;Shin Sung Kyun
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.130-137
    • /
    • 2005
  • In total body irradiation (T81) for leukemia, we have a two methode. One is a AP (anterior-posterior) method and the other is a Lateral methode. Our hospital used lateral methode. T81 must consider about body contour, because of homogeneous dose distribution. For compensation about irregular body contour, we use compensator. For T81 treatment, we must be considered, accurate manufacture of compensator and accurate calculation of dose. We developed the automatic program for T81. This program accomplished for compensator design and dose calculation for irregular body. This program was developed for uses to use in a windows environment using the IDL language. In this program, it use energy data for each energy: TMR, output factor, inverse square law, spoiler, field size factor. This program reduces the error to happen due to the manual. As a development of program, we could decrease the time of treatment plan and care the patient accurately.

  • PDF

Adaptive Phase Noise Compensator in Wireless ICS Repeater (무선 간섭 제거 중계기에서 적응형 위상 잡음 보상기 연구)

  • Jeong, Hae-Seong;Baek, Gwang-Hoon;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.481-488
    • /
    • 2011
  • In this paper, we study a novel wireless interference cancellation system(ICS) repeater based on OFDM system with phase noise analysis and performance evaluation. Recently, there were many researches about wireless repeater. The previous study is just considering the feedback channel cancellation algorithm. But, in wireless repeater system, the phase noise effect can exist at up and down converter of wireless repeater. In wireless repeater system, if there are phase noise effects, the performance of system will get worse. So, the phase noise compensator is needed in wireless repeater. Therefore, we propose adaptive phase noise compensator based on OFDM system in order to effectively cancel phase noise. In order to cancel interference, we adapt adaptive phase noise compensator in wireless repeater system. The adaptive phase noise compensator compensates phase noise effect. Therefore, in this paper, we analyze phase noise of wireless repeater based on OFDM system. In this paper, when phase noise power is -15 dBc and phase noise cutoff frequency is 100 kHz at 4QAM, the BER performance of propose algorithm is better about 4 dB than with adaptive equalizer and without phase noise compensator at $10^{-4}$.