• 제목/요약/키워드: comparison of power

검색결과 3,876건 처리시간 0.031초

Comparison of Antenna Parameters of R-/S-Band Standard Gain Horn Antennas

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • 제15권4호
    • /
    • pp.224-231
    • /
    • 2015
  • A comparison of the antenna parameters for R-band (1.7-2.6 GHz) and S-band (2.6-3.95 GHz) standard gain horn antennas has been performed by the Korea Research Institute of Standards and Science (KRISS), together with seven domestic participants from private companies and public institutions. Its purpose, as a proficiency test program of the 'Antenna Measurement Club' of KRISS, was to check equivalences in antenna parameter measurements between KRISS and the participants, particularly in the R-/S-band, to support antenna manufacturers and end users in Korea. The measurement parameters of this comparison are the power gain, radiation pattern, and reflection coefficient of the traveling standards for R-/S-band pyramidal standard gain horn antennas. The comparison used a gain comparison method and an extrapolation method to measure the power gain of the two traveling standards; the radiation patterns were measured in the far-field region of the transmitting and receiving antennas.

재밍 환경에 따른 STAP 및 SFAP 방식 성능 분석 (Performance Analysis of STAP and SFAP in Jamming Environments)

  • 김기윤
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.136-140
    • /
    • 2015
  • 본 논문에서는 적응형 배열 안테나에 적용되는 대표적 항재밍 기술로 알려진 STAP 및 SFAP 신호처리 방식의 시뮬레이션 성능을 비교 분석하였다. 시뮬레이션을 위해 두 방식의 가중 벡터(weighting vector)를 추정하는 방법으로 공통적으로 MMSE(Minimum Mean Square Error) 알고리즘을 사용하여 다양한 재밍환경에서 시뮬레이션을 통한 성능을 제시하였다. 특히, 재밍 전력 J/S(Jamming to Signal Power Ratio)에 따른 STAP 및 SFAP 성능 비교 분석, 신호대역에 대한 재밍 대역의 비율에 따른 성능 비교 분석 및 두 방식간 BER 성능을 비교하여 재밍 환경에 따른 항재밍 성능을 분석하였다.

능동전력필터를 위한 확장된 전류 동기 검출 알고리즘 (Algorithm of Extended Current Synchronous Detection for Active Power Filters)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

고온초전도 전력케이블 적용가능성 검토 (A Feasibility Study of HTS Power Cable in the Future)

  • 성기철;조전욱;권영길;류강식;강민규;유인근
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2000
  • In this study, we performed long lange power transmission expansion planning for conceptual design of HTS power cable in Seoul area. Since the HTS power cable has the high power transmission density and low loss characteristics in comparison with conventional power cables, the HTS power cable is introduced between the downtown and the suburbs in the future system in order to verify the feasibility of the HTS power transmission cables technically and to encourage the research activity in the area.

  • PDF

Control of Variable Reluctance Motors: A Comparison between Classical and Lyapunov-Based Fuzzy Schemes

  • Filizadeh, S.;Safavian, L.S.;Emadi, A.
    • Journal of Power Electronics
    • /
    • 제2권4호
    • /
    • pp.305-311
    • /
    • 2002
  • In this paper, two approaches for designing tracking controllers for a variable reluctance motor (VRM), namely the Lyapunov-based fuzzy approach and the classical approach, are compared. The nonlinear model of a VRM is first addressed. The two control schemes are introduced afterwards, and then applied to obtain tracking controllers. Simulation results of a sample case, to which the methods are applied, are also presented. Comparison of the methods based on the results obtained concludes the paper.

Performance Test of a Real-Time Measurement System for Horizontal Soil Strength in the Field

  • Cho, Yongjin;Lee, DongHoon;Park, Wonyeop;Lee, Kyouseung
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.304-312
    • /
    • 2016
  • Purpose: Soil strength has been measured using a cone penetrometer, which is making it difficult to obtain the spatial data required for precision agriculture. Our objectives were to evaluate real-time horizontal soil strength (RHSS) to measure soil strength in real time while moving across the field. Using the RHSS data, the tillage depth was determined, and the power consumption of a tractor and rotavators were compared. Methods: The horizontal soil-strength index (HSSI) obtained by the RHSS was compared with the cone index (CI), which was measured using a cone penetrometer. Comparison analysis in accordance with the measurement depth that increased at 5-cm interval was conducted using kriged maps at six sensing depths. For tillage control and evaluation of the power consumption, the system was installed with a potentiometer for tillage depth, a torque sensor from the rear axle, and a power take-off (PTO) shaft. Results: The HSSI was lower than the CI, but they were the same at 54.81% of the total grids for the 5-cm depth and at 3.85% for the 10-cm depth. In accordance with the recommended tillage map, tillage operations between 0 and 15 cm left 2.3% and 7% residue cover on the soil, and that between 20 and 10 cm covered a wider utilization of 3% and 18.4%, respectively. When the tillage depth was 15 cm, the comparison result of the power requirements between the PTO and rear axle in terms of control performance revealed that the maximum power requirements of the axle and PTO were 44.63 and 23.24 kW, respectively. Conclusions: An HSSI measurement system was evaluated by comparison with the conventional soil strength measurement system (CI) and applied to a tractor to compare the tillage power consumption. Further study is needed on its application to various farm works using a tractor for precision agriculture.

A Study On Comparison of Excellence between SERVQUAL and SERVPERV AL Scale

  • Cho, Yoon-Shik
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권1호
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this research is to compare whether SERVQUAL or SERVPERV AL scale is more excellent when explaining customer satisfaction and repurchase intention. The value of R2 which shows explaining power is used to test the excellence of the scale. As a result of comparison and analysis, SERVPERV AL scale showed better explaining power of customer satisfaction and repurchase intention than SERVQUAL. This result is because SERVPERV AL scale predicates overall estimation on utility of product/service.

  • PDF

UPS용 인버터의 LC필터 출력 전압제어를 위한 디지털 제어기 설계 (Design of Digital Controller for Output Voltage Control of LC Filter in 3-Phase UPS)

  • 조준석;이승요;최규하;목형수;신우석;한석우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.75-80
    • /
    • 1998
  • This paper presents an observer filter algorithm to estimated the load currents in the output voltage control of 3-phase uninterruptible power supply with deadbeat controller. As the result of the proposed algorithm, the sensors to measure the load currents is not required. The comparison of output voltage controls according to the methods of measuring the load currents is also presented in this paper. The results of comparison are shown by the simulation.

  • PDF

비교 시험에 따른 대전류 측정 센서 교정 결과 분석 (A calibration of high current measuring sensors by comparison tests)

  • 한종훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF