• 제목/요약/키워드: comparison of concentration

검색결과 2,543건 처리시간 0.029초

Insights into the significance of membrane structure and concentration polarization on the performance of gas separation membrane permeators: Mathematical modeling approach

  • Dehkordi, Javad Aminian;Hosseini, Seyed Saeid;Kundu, Prodip K.
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제67권
    • /
    • pp.333-346
    • /
    • 2018
  • This study presents a mathematical modeling approach for developing models based on non-ideal conditions related to the membrane structure including porous supporting layer and deformation under pressure. Comparison of the findings with experimental data reveal the importance of considering the resistance in porous supporting layer though the effect of concentration polarization in the permeate stream could be neglected. Investigations on deformation of fibers under pressure ascertain that at larger fiber inner radius to outer radius ratios, increasing driving force may lead to an initial increase in permeability. After that, the effects of deformation dominates and thus permeability may be decreased.

열탈착 방식을 연계한 GC/PFPD 시스템으로의 주입방식 차에 따른 악취황 성분의 검량특성: 주입부피 대비 주입농도의 고정방식 간 비교연구 (Changes in GC/PFPD Sensitivity in Relation with a Thermal Desorbing Technique for the Analysis of Sulfur Compounds: Comparison of Fixed Standard Concentration(FSC) vs Fixed Standard Volume(FSV))

  • 이기한;김기현
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2007년도 추계학술대회 논문집
    • /
    • pp.106-108
    • /
    • 2007
  • PDF

Numerical Analysis of Flow and Pollutant Dispersion over 2-D Bell Shaped Hills

  • Jung, Young-Rae;Park, Keun;Park, Warn-Gyu;Park, Ok-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1054-1062
    • /
    • 2003
  • The numerical simulations of flow and pollutant particle dispersion are described for two-dimensional bell shaped hills with various aspect ratios. The Reynolds-averaged incompressible Navier-Stokes equations with low Reynolds number $\kappa$-$\varepsilon$ turbulent model are used to simulate the flowfield. The gradient diffusion equation is used to solve the pollutant dispersion field. The code was validated by comparison of velocity, turbulent kinetic energy, Reynolds shear stress, speed-up ratio, and ground level concentration with experimental and numerical data. Good agreement has been achieved and it has been found that the pollutant dispersion pattern and ground level concentration have been strongly influenced by the hill shape and aspect ratio, as well as the location and height of the source.

Photo and Electrocatalytic Treatment of Textile Wastewater and Its Comparison

  • Singaravadivel, C.;Vanitha, M.;Balasubramanian, N.
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권1호
    • /
    • pp.44-49
    • /
    • 2012
  • Electrochemical and photochemical techniques have been proved to be effective for the removal of organic pollutants in textile wastewater. The present study deals with degradation of synthetic textile effluents containing reactive dyes and assisting chemicals, using electro oxidation and photo catalytic treatment. The influence of various operating parameters such as dye concentration, current density, supporting electrolyte concentration and lamp intensity on TOC removal has been determined. From the present investigation it has been observed that nearly 70% of TOC removal has been recorded for electrooxidation treatment with current density 5 mA/$dm^2$, supporting electrolyte concentration of 3 g/L and in photocatalytic treatment with 250 V as optimum lamp intensity nearly 67% of TOC removal was observed. The result indicates that electro oxidation treatment is more efficient than photocatalytic treatment for dye degradation.

유가식과 세포재순환 연속공정을 이용한 항혈전제 hirudin의 생산 (Production of an Anticoagulant Hirudin by Fed-batch and Continuous Cell Recycle Fermentations Using Recombinant Saccharomyces cerevisiae)

  • 최치민;김명동;이상기;서진호
    • KSBB Journal
    • /
    • 제13권4호
    • /
    • pp.456-460
    • /
    • 1998
  • Fed-batch fermentations were carried out in order to improve the efficiency of hirudin production by recombinant Saccharomyces cerevisiae. A fed-batch fermentation done with the optimized semi-synthetic medium resulted in a maximum hirudin concentration of 342mg/$\ell$ by keeping a galactose concentrations between 10 and 30g/$\ell$ which corresponded to a 11.4-fold increase in hirudin concentration compared with the simple bach fermentation done with the same medium. Comparison of the chromatographic pattern of proteins in the growth medium clearly showed that the use of the semi-synthetic medium is more advantageous for separation of hirudin than the case o fusing the complex medium. Continuous cell recycle fermentation done at dilution rate of 0.1h-1 and an inlet galactose concentration of 100g/$\ell$ yielded a maximum hirudin productivity of 19.1mg hirudin/$\ell$$.$h.

  • PDF

Enzyme-linked Immunosorbent Assay(ELISA)를 이용한 혈청 및 원유 중의 Mycobacterium bovis 항체 검출에 관한 연구 (Studies on Enzyme-linked Immunosorbent Assay(ELISA) for Detection of Antibody to Mycobacterium bovis in Serum and Milk)

  • 심항섭;국정희;박병옥;김성열;박유순
    • 한국동물위생학회지
    • /
    • 제20권2호
    • /
    • pp.133-142
    • /
    • 1997
  • In order to supplement a diagnostic method for detection of infectious cattle to bovine tuberculosis, performed ELISA for detection of antibody to if bovis in serum and milk. The diagnostic efficacy of the established ELISA was compared with test of the tuberculin skin test for bovine tuberculosis. The positive corresponding rate of serum ELISA and tuberculin skin test showed 84.3%, milk ELISA and tuberculin skin test showed 75.0%, milk ELISA and serum ELISA showed 75.0% respectively. Comparison of the serum and milk to tuberculin antibody concentration in tuberculin positive cattle, the milk contained 1/100-1/150 concentration compared serum tuberculin concentration. The established ELISA was considered efficient for detection of antibodies to M bovis in serum and milk.

  • PDF

CI기관에 있어서 세라믹 필터트랩에 관한 연구 (A study on the ceramic filter trap in CI engine)

  • 한영출;유정호
    • 오토저널
    • /
    • 제10권5호
    • /
    • pp.54-60
    • /
    • 1988
  • This study is a theoretical analysis and experimental effect of oxygen concentration, exhaust velocity and trap inlet temperature on particulate ignition temperature with installation of ceramic filter trap in diesel engine. So the following results are obtained. 1, Based on the fundamental experiments of the regeneration process, the analytical model was developed and the results from the analytical model agreed with the experiments, then the validity of the model was proved. 2, The ignition temperature for accumulated particulate was proportional to the exhaust velocity and it was known that the optimum exhaust velocity was about 15m/sec. 3, The ignition temperature for accumulated particulate was inversely proportional to the oxygen concentration and the trap inlet temperature, and a minimum oxygen concentration of 5% was required to sustain regeneration. 4, This experimental filter trap(EX-66) is found about 30% of smoke reduction efficiency in comparison with existing muffler.

  • PDF

방사선 물질 $Li^+,Rb^+,Cs^+$이 Neurospora crassa의 성장 일주기에 미치는 영향 (The Comparison of Radiactive Elements $Li^+,Rb^+,Cs^+$Effect on the Growth Circadian Rhythm in Neurospora crassa)

  • 한상진
    • Environmental Analysis Health and Toxicology
    • /
    • 제8권1_2호
    • /
    • pp.11-17
    • /
    • 1993
  • Radioactive elements Li/sup +/, Rb/sup +/and Cs/sup +/ effect the period shortening in proportion to the higher concentration on the growth of Neurospora crassa. 1 mM LiCl presented the result of the period length 0.52 h shorter than average circadian rhythm 21.66 h. 1 mM RbCl reduced the period length 1.13 h than control period 21.89 h and 1 mM CsCl reduced 2.12 h than control period 21.89 h. In the equal concentration Cs/sup +/ had an extreme effect. Fatal doses of Li/sup +/, Rb/sup +/ and Cs/sup +/ are 20mM, 30mM and 20mM. In the fatal concentration Neurospora didn't develop more after 7 days and the formation of spores were not given in regular order. Circadian length of Neurospora decreased generally at the last cycle of the growth.

  • PDF

갈수기(渴水期) 하천(河川)에서의 오염물질(汚染物質)의 확산(擴散) 및 이동(移動) (Low Flow Pollutant Transport in Natural Rivers)

  • 서일원
    • 상하수도학회지
    • /
    • 제7권1호
    • /
    • pp.29-36
    • /
    • 1993
  • The complex nature of low flow mixing in natural channels has been investigated using both laboratory experiments and the numerical solution of a proposed mathematical model that is based on a set of mass balance equations describing the mixing and mass exchange mechanisms. Laboratory experiments, which involved collection of channel geometry, hydraulic, and dye dispersion test data, were conducted in a model of four pool and riffle sequences in a 49-m long tilting flume. The experimental results show that flow over the model pool-riffle sequences is highly non-uniform. Concentration-time curves are significantly skewed with long tails. Comparison between measured and predicted concentration-time curves shows good agreement in the general shape, peak concentration and time to peak. The proposed model shows significant improvement over the conventional one-dimensional dispersion model in predicting natural mixing processes in open channels under low flow conditions through pools and riffles.

  • PDF

CALPUFF and AERMOD Dispersion Models for Estimating Odor Emissions from Industrial Complex Area Sources

  • Jeong, Sang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2011
  • This study assesses the dispersion and emission rates of odor form industrial area source. CALPUFF and AERMOD Gaussian models were used for predicting downwind odor concentration and calculating odor emission rates. The studied region was Seobu industrial complex in Korea. Odor samples were collected five days over a year period in 2006. In-site meteorological data (wind direction and wind speed) were used to predict concentration. The BOOT statistical examination software was used to analyze the data. Comparison between the predicted and field sampled downwind concentration using BOOT analysis indicates that the CALPUFF model prediction is a little better than AERMOD prediction for average downwind odor concentrations. Predicted concentrations of AERMOD model have a little larger scatter than that of CALPUFF model. The results also show odor emission rates of Seobu industrial complex area were an order of 10 smaller than that of beef cattle feed lots.