Measurement of Solar Cell Using LED-based Differential Spectral Responsivity Comparator under High Background Irradiance

  • Zaid, Ghufron;Park, Seong-Chong;Lee, Dong-Hoon;Park, Seung-Nam
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.293-294
    • /
    • 2009
  • The spectral responsivity of solar cells has been measured under high background irradiance using an LED-based differential spectral responsivity Comparator (DSR-C). The comparator developed is fully automated and has some advantages: It does not need a chopper to modulate the light. Unlike the conventional method, it does not require a monochromator to select wavelength. It covers a wavelength range up to 1200 nm. The wavelength range of the comparator is limited by the spectral power distribution of the LEDs and the spectral responsivity of the standard detector. An active temperature control was utilized to meet the specified standard conditions of solar cell test. This work shows the effect of different levels of background irradiance on the spectral responsivity and the importance of same background irradiance for solar cell test as specified by the corresponding standard.

  • PDF

전류변성기 비교측정 장치의 현장 평가기술 (On-Site Evaluation Technique of Current Transformer Comparator System)

  • 정재갑;이상화;권성원;강전홍;김명수
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.926-932
    • /
    • 2007
  • A recently developed methods for on-site calibration of the current transformer (CT) comparator system have been reviewed in the paper. The method utilizes several traveling standards, which consist of the CT, non-reactive standard resistors, wide ratio error CT, and shunt resistors. The traveling CT is used for absolute evaluation of a standard CT belonging to industry. The non-reactive standard resistors and a wide ratio error CT are used for the linearity check of errors in the current comparator. The shunt resistors are used for evaluation of CT burden of industry.

66kV급 전압변성기 비교측정 장치의 현장 평가설비 구축 (Construction of On-Site Calibration Facilities of 66 kV Voltage Transformer Comparator System)

  • 정재갑;이상화;권성원;김명수
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1268-1274
    • /
    • 2007
  • A recently developed methods for the on-site calibration of the voltage transformer (VT) comparator system have been reviewed in the paper. The method utilizes the several traveling standards consisting of the VT, the non-reactive standard resistors, the wide ratio error VT, and the decade resistors. The VT is used for the absolute evaluation of a standard VT belonging to the industry. The non-reactive standard resistor and wide ratio error VT are used for the linearity check of errors in the voltage comparator of the industry. The decade resistors are used for evaluation of a VT burden of the industry.

전압변성기 비교기를 이용한 커패시터와 인덕터의 절대 평가 (Absolute Evaluation of Capacitor and Inductor Using Voltage Transformer Comparator)

  • 한상길;김윤형;정재갑;김한준;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.285-290
    • /
    • 2008
  • We have developed the absolute evaluation technique of capacitor and inductor by measuring the phase displacement as a function of resistance of employed resistors in voltage transformer(VT) comparator. The methods were applied to the capacitor with the range of 100 nF - $5{\mu}F$ and the inductor with the range of $100{\mu}H{\sim}1\;H$. The capacitance values of capacitor obtained using our method are consistent within the expanded uncertainty those obtained using capacitor bridge. The inductance values of inductor obtained using our method are also consistent within the expanded uncertainty those obtained using LCR meter.

광범위 비오차 표준 전류변성기의 개발 및 그 응용 (Development of The Standard Current Transformer with Wide Ratio Error and Its Application)

  • 권성원;정재갑;이상화;김문석;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.302-307
    • /
    • 2006
  • Standard current transformer(CT) with the nominal ratio errors in the range of - 10 % to + 10 % has been developed. Linearity of the CT ratio error measuring system (CT comparator) has been tested by using wide ratio error standard current transformer(WRE CT). The developed WRE CT can be used to evaluate the linearity of the CT comparator by comparing both the theoretical values and experimental values of the WRE CT. The developed method has been successfully applied for calibration and correction in the CT comparator belonging to industry.

초정밀 광범위 비오차 전압변성기의 개발 및 그 응용 (Development of The Accurate Potential Transformer with Wide Ratio Error and Its Application)

  • 권성원;정재갑;이상화;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.317-322
    • /
    • 2006
  • A accurate potential transformer(PT) with the nominal ratio errors in the wide range of - 9 % to + 11 % has been developed. The developed wide ratio error PT can be used to evaluate the linearity of the PT comparator by comparing both the theoretical values as standard values and experimental values of the PT. The new method has been successfully applied for calibration and correction in the PT comparator including very low ratio error values from ${\pm}0.005%$ to ${\pm}0.3%$ belonging to industry.

Reactor Neutron Activation Analysis by a Single Comparator Method

  • Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.137-149
    • /
    • 1973
  • 중성자 방사화 및 방사능 계측에 관계하는 핵데타를 세밀히 연구검토하여 망간을 불순물로 함유하고 있는 철선을 단일비교체로 한 중성자 방사화분석법을 발전시켰다. 유효반응 단면적의 변화를 원자로 내부 스펙트럽의 열외 중성자의 비율과 같은 스펙트럼 지표 및 그 외 다른 변수의 함수로 검토하였으며 조사위치에서 중성자 스펙트럽의 변위로 생기는 오차를 토의하였다. 각원소의 이미 아는양을 취하여 단일비교체와 함께 조사한 다음 본법에 의해서 그 함량을 산출하여서 원래 취한 양과 비교하였다. 그 결과 우연오차는 일반적인 비교법으로 얻은 오차보다 크지 않았으나 계통적 오차는 대략 20%이내였다. 본법을 모나자이트 중에 함유된 14개 희토류 원소의 정량과 표준배추시료 중에 있는 다른 7개의 원소정량에 적용하였다. 그 결과 분석치는 만족할만한 재현성을 나타내었으며 종래의 비교법으로 얻을 수 있는 정도의 정착성으로 이들 원소를 분석할 수 있었다.

  • PDF

전압변성기 비교기를 이용한 부담의 현장교정 기술 (On-Site Calibration Technology of Burden using Voltage Transformer Comparator)

  • 정재갑;권성원;박영태;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.503-507
    • /
    • 2005
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of VT burden used. Thus, precise measurement of burden is very important for the evaluation of VT. A method of evaluation for VT burden has been developed by employing the portable decade resistor, with AC-DC resistance difference less than 10-3. The burden value(value and power factor) can be obtained by conductance and susceptance, obtained by measuring the change of ratio error and phase angle error caused by the resistance change of decade resistor. The burden value and power factor obtained by the method are consistent with those obtained using power analyzer within corresponding uncertainties.

PFC용 부스트 컨버터의 병렬화에 의한 효율 개선 (An Improvement Parallel to the Efficiency of Boost Converter for Power Factor Correction)

  • 전내석;장수형;전일영;박영산;안병원;이성근;김윤식
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.120-124
    • /
    • 2001
  • A new technique for improving the efficiency of single-phase high-frequency boost converter is proposed. This converter includes an additional low-frequency boost converter which is connected to the main high-frequency switching device in parallel. The additional converter is controlled at lower frequency. Most of the current flows in the low-frequency switch and so, high-frequency switching loss is greatly reduced accordingly Both switching device are controlled by a simple method; each controller consists of a one-shot multivibrator, a comparator and an AND gate. The converter works cooperatively in high efficiency and acts as if it were a conventional high-frequency boost converter with one switching device. The proposed method is verified by simulation. This paper describes the converter configuration and design, and discusses the steady-state performance concerning the switching loss reduction and efficiency improvement.

  • PDF

전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술 (Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor)

  • 이상화;강전홍;김명수;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.