• Title/Summary/Keyword: communication cable

Search Result 439, Processing Time 0.025 seconds

A Study on Management of Cable Broadcasting Business and Activities of the National Cable Broadcasting Association in 1960s (1960년대 전반기 한국 유선방송사업의 운영과 전국유선방송협회 활동의 의의)

  • Yoon, Sangkil
    • Korean journal of communication and information
    • /
    • v.80
    • /
    • pp.193-223
    • /
    • 2016
  • This study tried to examine the transfiguration process of cable broadcasting business in the early 1960s of Korea. Especially, on the basis of a critical mind of examining autonomy of cable broadcasting operator as agent, this paper examined not only the technical and financial business management, and the drawing up of a program, but also business plans of the National Cable Broadcasting Association in initial establishment time of 1960s.

  • PDF

A Design Of Physical Layer For OpenCable Copy Protection Module Using SystemC (SystemC를 이용한 OpenCableTM Copy Protection Module의 Physical Layer 설계)

  • Lee, Jung-Ho;Lee, Suk-Yun;Cho, Jun-Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.157-160
    • /
    • 2004
  • 본 논문은 미국 차세대 디지털 케이블 방송 표준 규격인 오픈케이블($OpenCable^{TM}$)의 수신제한 모듈인 CableCard의 Physical Layer를 SystemC의 TLM(Transaction Level Modeling)과 RTL(Register-Transfer Level) 모델링 기법으로 설계하였다. 본 논문에서 설계한 CableCard의 Physical Layer는 PCMCIA Interface, Command Inteface 그리고 MPEG-2 TS Interface 로 구성된다. CableCard가 전원이 인가될 때, 카드 초기화를 위하여 동작하는 PCMCIA 인터페이스는 16 비트 PC 카드 SRAM 타입으로 2MByte Memory와 100ns access time으로 동작할 수 있게 설계하였다. PCMCIA 카드 초기화 동작이 완료된 후, CableCard의 기능을 수행하기 위하여 두 개의 논리적 인터페이스가 정의되는데 하나는 MPEG-2 TS 인터페이스이고, 다른 하나는 호스트(셋톱박스)와 모듈 사이의 명령어들을 전달하는 명령어 인터페이스(Command Interface)이다. 명령어 인터페이스(Command Interface)는 셋톱박스의 CPU와 통신하기 위한 1KByte의 Data Channel과 OOB(Out-Of-Band) 통신을 위한 4KByte의 Extended Channel 로 구성되고, 최대 20Mbits/s까지 동작한다. 그리고 MPEG-2 TS는 100Mbits/s까지 동작을 수행할 수 있게 설계하였다. 설계한 코드를 실행한 후, Cadence사의 SimVision을 통해서 타이밍 시뮬레이션을 검증하였다.

  • PDF

Interface Effect Analysis between Undersea Fiber Optic Cable and Underwater Acoustic channel (수중 음향 채널의 해저 광케이블 간섭 효과 분석)

  • Im, Yo-Wung;Lim, Pil-Sub;Lee, Jeong-Gu;Kim, Chun-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.9
    • /
    • pp.979-986
    • /
    • 2015
  • Security solutions using fiber-optic cable have not yet secured a solid technical stability, through which the Acoustic detection security system also did not have a complete defense techniques such as false alarm and detecting fail due to a number of variables. In this paper, we investigate 4 characteristics for the channel of underwater acoustic communication. We also construct detection system as a construction method for security system using optical cable through the analysis of acoustic signal in underwater. We perform analysis of signal characteristics and noise of underwater optical cable, and then we confirms the possibility of real application.

Analysis of Electromagnetic Wave for Spark Plug Cable in Distributorless Spark Ignition System (무배전기식 불꽃 점화 시스템의 점화 플러그 케이블에서 발생되는 전자파의 분석)

  • Kang, Sang-Won;Choe, Gwang-Je;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2013
  • It is an analysis about electromagnetic wave which is generated from a Spark plug cable of Distributorless spark ignition system. In case of Distributorless spark ignition system, high frequency generation is an ignition coil and Spark plug cable and Spark plug could be activated with electromagnetic wave radiation antenna. I calculated a resonant frequency with HFSS by measuring length of Spark plug cable and Spark plug. The antenna was considered as ${\lambda}/4$ monopole antenna in this calculation. According to power spectrum measurement analysis of engine room radiated electromagnetic wave and calculated Resonant frequency, it is possible to find out that the Distributorless spark ignition system radiates high frequency energy in certain frequency band.

Near-end Cross-talk Analysis of Unshielded Twisted Pair Cable using the Transmission Line Model (전송선로 모델을 이용한 UTP 케이블의 NEXT 해석)

  • Lee, Won-Hui;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.2
    • /
    • pp.59-63
    • /
    • 2009
  • The UTP cable has been widely used, recently it is being developed for use in the UHF frequency band. One important characteristic of the UTP cable is NEXT. This research is to develop a pitch selection technique for an UTP cable which leads to a satisfactory NEXT. The transmission line model involving mutual inductances and capacitances between line pairs is used, and the simulation was carried out for frequencies from 1 MHz to 600 MHz. With respect to the worst margin of the NEXT for a Cat. 6 cable the simulation and measurement results show a good agreement.

  • PDF

A study on the moving picture transmission method between the accident sites and control center (철도 사고현장의 동영상 전송방안에 관한 연구)

  • Cho, B.K.;Chang, S.G.;Ryu, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1300-1302
    • /
    • 2003
  • CCTV network has been implemented to transmit the image information of platform, ticket gate and transfer section to local headquarters in the KNR(Korean National Railroad). But, communication system for transferring image information around accident field or wayside has not been established yet. thus, at present implementation of communication equipment is necessary for dynamic image of unspecified accident to be transmitted to headquarters. Copper cable communication network is run by KNR, but it is processing installation of optical cable in connection with the implemental plan for high-speed network from now on. And, the capacity of communication channel will be guaranteed much more than now between station and station, station and central headquarters when optical cable is completed. This study analyzes the image equipment of field for transmission and estimated matters to transmit image information of accident field to headquarters with using communication infrastructure. And, the study considers implemental method of communication network for long-distance image transmission from dozens to hundreds kilometers.

  • PDF

A Study on the Viewing Diversity of Pay Television: Centering on Diversity in Cable Company's Tiering Package (유료방송환경에서의 시청다양성에 관한 연구 - Cable So의 상품별 채널다양성 분석을 중심으로)

  • Hwang, Sung-Yon;Kim, Myoung-Joong
    • Korean journal of communication and information
    • /
    • v.49
    • /
    • pp.39-56
    • /
    • 2010
  • This study on the exposed the viewers diversity as a basic cable television service. Diversity is the most basic goal of broadcasting policy has important implications. But still, such as cable and pay-media research on the viewing diversity has made a limited basis. SO much to offer for the cable offers viewers receive the number of channels available to compare the diversity of the field was verified. Price rises of analysis for the cable the more the number of channels offered to supply the channel has increased the diversity of the field. SO granted in accordance with the results of a market strategy, but for a variety of channels to be provided by a policy perspective, the price depending on the choice of a variety of audiences can be quite limited means. That is a wide range of viewers watching the channel had a right to be limited. These phenomena to improve the pay television service and the need to manage the Product channel diversity index was raised.

  • PDF

Fault Monitoring System for Cables Using a Compact Impedance Analyzer (소형 임피던스 분석기를 이용한 케이블의 결함 감시 시스템)

  • Yoon, Chai-Won;Yong, Hwan-Gu;Kim, Kwangho;Nah, Wansoo;Chae, Jang-Bum;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.872-879
    • /
    • 2017
  • This work presents a cable fault monitoring system based on the differential frequency domain reflectometry using a compact impedance analyser which is composed of a direct digital synthesizer, an op amp and a gain/phase detector with a micro controller. The proposed system can replace expensive vector network analysers for frequency domain reflectometry and therefore be deployed in sensor networks for long term multi-point cable monitoring. Effectiveness of the system is experimentally confirmed by diagnosing the status of the power cable.

A Study on the Generation of the Earth Potential and Communication Line Noise. (대지전위와 통신회선 잡음 발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.33-38
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

  • PDF