Browse > Article
http://dx.doi.org/10.5515/KJKIEES.2017.28.11.872

Fault Monitoring System for Cables Using a Compact Impedance Analyzer  

Yoon, Chai-Won (College of Information and Communication Engineering, Sungkyunkwan University)
Yong, Hwan-Gu (College of Information and Communication Engineering, Sungkyunkwan University)
Kim, Kwangho (College of Information and Communication Engineering, Sungkyunkwan University)
Nah, Wansoo (College of Information and Communication Engineering, Sungkyunkwan University)
Chae, Jang-Bum (College of Engineering, Ajou University)
Kim, Byung-Sung (College of Information and Communication Engineering, Sungkyunkwan University)
Publication Information
Abstract
This work presents a cable fault monitoring system based on the differential frequency domain reflectometry using a compact impedance analyser which is composed of a direct digital synthesizer, an op amp and a gain/phase detector with a micro controller. The proposed system can replace expensive vector network analysers for frequency domain reflectometry and therefore be deployed in sensor networks for long term multi-point cable monitoring. Effectiveness of the system is experimentally confirmed by diagnosing the status of the power cable.
Keywords
Impedance Analyzer; Power Cable; Frequency Domain Refectometry;
Citations & Related Records
연도 인용수 순위
  • Reference
1 U. S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation, "Inaccessible or underground power cable failures that disable accident mitigation systems or cause plant transients", NRC Generic Letter, Feb. 2007.
2 C. Furse, Y. C. Chung, R. Dangol, M. Nielsen, G. Mabey, and R. Woodward, "Frequency-domain reflectometry for on-board testing of aging aircraft wiring", IEEE Transactions on Electromagnetic Compatibility, vol. 45, no. 2, pp. 306-315, May 2003.   DOI
3 Q. Shi, U. Troeltzsch, and O. Kanoun, "Detection and localization of cable faults by time and frequency domain measurements", 2010 7th International Multi-Conference on Systems Signals and Devices, Amman, Jordan, pp. 1-6, Jun. 2010.
4 Y.-J. Shin, E. J. Powers, T. -S. Choe, C.-Y. Hong, E.-S. Song, J.-G. Yook, and J. B. Park, "Application of time-frequency domain reflectometry for detection and localization of a fault on a coaxial cable", IEEE Transactions on Instrumentation and Measurement, vol. 54, no. 6, pp. 2493-2500, Dec. 2005.   DOI
5 노현승, 김양석, 채장범, 김병성, "오차 보정 방법을 이용한 시간 영역 임피던스 측정의 정확도 개선", 한국전자파학회논문지, 23(11), pp. 1315-1322, 2012년 11월.   DOI
6 용환구, 채장범, 김병성, "미약한 결함에 의한 반사 계수 변화를 이용한 제어 및 전력 케이블의 상태 진단", 한국전자파학회논문지, 25(12), pp. 1269-1274, 2014년 12월.   DOI
7 OA-13 Current Feedback Loop Gain Analysis and Performance Enhancement, http://www.ti.com/lit/an/snoa366b/snoa366b.pdf, Texas Instruments, Apr. 2013.