• 제목/요약/키워드: communication cable

Search Result 439, Processing Time 0.027 seconds

Cable/Wireless Integrated Server for WiBro Contents (와이브로 컨텐츠를 위한 유/무선 통합 서버)

  • Kim, Bae-Hyun;Heo, Jin-Kyoung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.73-78
    • /
    • 2009
  • We researched economic efficiency and possibility of game portal service based PDA/Smart phone by popularize of next generation portable internet WiBro. PDA/Smart phone are difficult to equal level content service with PC, because of it has low CPU and memory than PC. This paper are implemented paper of integrated server of Cable or Wireless for WiBro contents. In this research, we implemented and show test result of CP killer contents in PDA. It can apply to WiBro portable internet and has required many functions in integrated server for cable or wireless. CP Killer contents for WiBro portable internet is developed by PC server base on Window XP. It can accept next generation wireless LAN, portable internet and ubiquitous issues. We expect activation of commercial use that WiBro contents and server trading.

  • PDF

Developing Equipment to Detect the Deterioration Status of 6.6kV Power Cables in Operation at Power Station (발전소에서 운전 중인 활성 6.6kV 전력 케이블의 고장상태를 파악하는 장치의 개발)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.197-203
    • /
    • 2014
  • The technology to predict and prevent an accident of the cable system in power station is required. The techniques of inactivated diagnosis, partial discharge and $tan{\delta}$, have been adopted to diagnoze the operating characteristics of cables, but it is not so easy to find out problems in cables in an inactive state before the cable accident happens. In this paper, we did a research on the 6.6kV high-power cables, installed at Korean Western Power Station Co., Ltd. in order to diagonize the cables, playing a major role at the station. We have developed an equipment to measure an insulation resistance based on the temperature and current of the cable. By installing the system in a power station, we could find abnormal status for evaluation of the lifetime. In the short term, by analyzing the data, we apply the research result to the diagnosis and evaluation of the 6.6kV power cables. In the long run, however, we plan to reduce the cost of the installation and operation of cable systems at power stations.

Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station (발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.213-218
    • /
    • 2017
  • High-voltage power systems operate in order to generate and transmit electric power at power stations. Compared to low-power systems, high-power systems are complex in structure, large-scale, and expensive. When high-power cable accidents occur, most facilities are incapacitated-including low-power systems-causing huge economic losses. Great care must therefore be taken in designing, installing and managing power systems. Although dependent on installation circumstances and usage conditions, in some cases the cross-sectional areas of cables fall short of the critical area due to the expansion of and improper design and installation of power facilities. In this situation, the exceeded ampacity (allowable current) above the critical value caused by the operating current initiates the deterioration processes of power cables. In order to systematically monitor power cables operating at power stations, we have developed the first device of its kind in Korea. In this paper, we present the analyzed characteristics of expected temperatures of cables based on the load current of high-voltage cables operating at Korean Western Power Co. Ltd. We can predict the lifetime of cables by analyzing the temperature obtained from our device.

Comparison and Examination of the Measured Data With the Data from Other Company for the Conductor and Sheath Temperatures of Live 6 kV CV Single Core Cables (활선 6 kV CV 단심 케이블의 도체 및 표면온도 측정 데이터에 관한 타사 데이터와의 비교검토)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • The demand for electric power is increasing every year in Korea. All the systems adopted at power stations in order to generate and transmit electric power should operate in perfect condition or reliability. The device for transmitting the generated high-voltage electric power is 6 kV CV single core cables. The manufacturing companies of the cables makes an official announcement that the operating lifetime of their cables is about 30years. But from the moment of operation the deterioration precesses of worsening the characteristics of cables starts. Since the reliability for the status of installed cables in deterioration has not been diagnosed, the cables can be broken at any unexpected moments. In order to prevent the abrupt cable accident by systematically monitoring the cable status, we have invented the first device in Korea. We have installed our device at Korea Western Power Co. Ltd. in order to diagnose the live cables. In this paper, we present our research results of measured temperatures of inner conductor and surface and the compared results of those data with other cable company. We also show that our results agree with those made by other company.

A Study on Cable Lifetime Evaluation Based on Characteristic Analysis of Insulation Resistance by Acceleration Factor of the Arrhenius Equation (아레니우스 방정식의 가속인자를 만족하는 절연저항특성 분석에 의한 케이블 수명평가 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.231-236
    • /
    • 2014
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. In this paper, in order to determine a stable operation of high-voltage power cable, used as a unique means of delivering electric power generated at a power station, we figure out the time rate of change of insulation resistance following a decay accelerating factor Arrhenius equation. With the data from the insulation resistance, we can determine the lifetime of power cable in operation.

A Content Analysis of Digital Audience Replies to Video Advertising Types: Focused on Viral Video and Cable Broadcasting Advertisement (영상광고 유형별 디지털 이용자의 댓글 내용분석에 관한 연구: 바이럴 동영상 광고와 케이블 방송광고를 중심으로)

  • Ji, Won-Bae;Kim, Woon-Han
    • Journal of Digital Contents Society
    • /
    • v.19 no.7
    • /
    • pp.1303-1312
    • /
    • 2018
  • The study analyzed the evaluation of the advertisement effect by the score and the method of the advertisement comments in ad evaluation in online site, 'TVCF'. The results are as follows. First, Internet viral advertisement showed higher number of ad comments and higher evaluation of advertisement effect than cable broadcasting advertisement. Second, the results of analysis of the difference of advertisement evaluation according to ad types and digital user characteristics showed that women are more positive than men toward both cable broadcasting and internet viral advertisement.

FPGA Design and Sync-Word Detection of CATV Down-Link Stream Transmission System (CATV 하향 스트림 적용 시스템에서 동기 검출 방안 및 FPGA 설계)

  • Jung, Ji-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.286-294
    • /
    • 2011
  • Cable modems typically are implemented by a forward error correction(FEC) scheme. The ITU-T Recommendation J-38 Annex B specifies using 64- and 256- quadrature amplitude modulation (QAM) and extended RS coding scheme. In implementing the cable modem, there are some problems to fabricate and fitting on FPGA chip. First, many clocks are needed in implementing cable modem because of different code rate and different modulation types. To reduce the number of clocks, we use the two memories, which are different clock speed for reading and writing data. Second, this system lost the bit-synchronization and frame-synchronization in decoder, the system recognize that all data is error. This paper solves the problems by using simple 5-stage registers and unique sync-word. Based on solutions for about problems, the cable modem is fabricated on FPGA chip name as Vertex II pro xc2vp30-5 by Xilinx, and we confirmed the effectiveness of the results.

Design of the Upstream Cable Modem for Symmetric Multimedia Services over HFC Networks (HFC망 기반 대칭형 멀티미디어 서비스를 위한 상향 채널 케이블 모뎀 설계)

  • Cho, Byung Hak
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.401-412
    • /
    • 2005
  • We propose and design the algorithms of symbol timing recovery, carrier recovery, and equalization for the receiver of S-DMT cable modem, which supports more channels and better symmetric mutimedia services over HFC network. We evaluate the performance of the concatenated entire receiving system of 16QAM, 64QAM in the mixed noise channel of AWGN, ISI and impulse. The result of evaluation shows those algorithms work correctly and designed S-DMT receiver has good performance. We also verify the designed system has excellent immunity against impulse noise channel of practical Cable TV networks by the result of simulation with the parameters of impulse internal $\varepsilon$ and noise power $\gamma^{k}$.

A Study on the Calculation of Allowable Continuous Current for HVDC Submarine Power Cables (HVDC 해저케이블의 연속허용전류 계산에 관한 연구)

  • Lim, Chung-Hwan;Park, Hung-Sok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.815-824
    • /
    • 2022
  • The growing integration of intermittent renewable sources like offshore wind energy increases the need for transferring electric energy over long distances, which may include sea crossings. One of the solutions available for bulk electric power transmission across large distances encompassing wide and deep sea is using HVDC submarine power cables. However, there are no standards or research related to the calculation of the continuous allowable current with various ocean conditions of a DC power cable that does not have an alternating magnetic field. In this study, assuming the typical two types of subsea cable models and two areas of the south coast and the west coast marine conditions, a continuous allowable current simulation of DC cables was performed. As a simulation result, the DC cable continuous allowable current find out the gradient reduction characteristics based on subsea base depth.

Communication Cable Fault Localization Based on Chirp Signal Parameter Estimation (첩 신호 파라메터 추정 기반 통신 케이블 고장점 탐지에 관한 연구)

  • Lee, Chun-Ku;Han, Seul-Gi;Park, Jin-Bae;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1782_1783
    • /
    • 2009
  • Reflectometry that has been used to localize faults on a cable is introduced. One of the key point of reflectometry is finding time delay between the incident and reflected signals. In this paper, we propose new reflectometry that use Gaussian enveloped linear chirp signal, and use Kalman filter to estimate frequency rate parameter of the chirp signal. From the estimated frequency rate parameter, we can measure the time delay. In a simulation assuming open ended cable, the proposed method is proved to give a good estimation results.

  • PDF