• Title/Summary/Keyword: commercial building

Search Result 784, Processing Time 0.024 seconds

A Study on the Right of Light Impact at Adjacent Residential Area by High-rise Residential Commercial Complex Building (상업지역내 고층건물의 인접주거 지역 일조권 영향에 관한 연구)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.10-18
    • /
    • 2009
  • In order to determine the violation of right of light impact at adjacent residential area by high-rise building, analysis on the right of light for high-rise residential commercial complex building block at Gahngnam-ku, Seoul, Korea was carried out using Google Sketchup Pro. After the analysis th sunshine duration of B apartment decreased from 5 hours 16 minutes 3 hours 48 minutes by I hour 42 minutes after construction. It shows that the total sunshine duration is less than the Seoul City Government Standard which is more than 4 hours a day, or more than 2 consecutive hours. Lowering the heights of apartments by 54m would increase the total sunshine duration which would meet the Seoul City Government Standard by four hours seven minutes. Problems that rna lead to the violation on the right of light in the adjacent area should be discussed in advance and minimized by analyzing the right of light among buildings and structures which are scheduled to be constructed on the site during construction penni! process when high-rise building is proposed.

Change of the Kyeong-seong-bu Administration Office's former Site after the Office's Moving out in 1926 -From a Administrative Center to a Commercial Center- (1926년 경성부청 이전 후 옛 청사 터의 변화 -행정 중심지에서 상업 중심지로 -)

  • Kim, Myungsun
    • Journal of architectural history
    • /
    • v.28 no.2
    • /
    • pp.19-30
    • /
    • 2019
  • The former administration office building of Kyeong-seong-bu(京城府) was a building converted from the Japanese residency-general's of Kyeong-seong(京城理事廳) which was originally built as the Japanese consulate in Joseon(日本領事館). It was too worn and too small as a Kyeong-seong-bu administration office even with several annexes. Kyeong-seong-bu tried to build a new big administration office building at the vacant north side of the same site, which was closely faced to the rotary in front of the Bank of Joseon(朝鮮銀行前廣場). But this trial was ended in vain due to insufficient budget. Therefore Kyeong-seong-bu built a new administration office building in another site and moved to it in 1926 with debts. For paying for the debts Kyeong-seong-bu sold the former site after partitioning with new roads through it. As a result the nature of the former site and its surroundings was changed. This study traces the changes and inquires how the authorities in the colonial Joseon and various commercial powers of Kyeong-seong-bu behaved for their own interests in the meantime. It makes use of the historical records and documentary literatures between early 1910s and early 1930s.

Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

Characteristics of Block Formation and Commercialization of Residential Blocks commercial area along Urban Arteries - Case study of commercial and residential area on Teheran-ro in Gangnam-gu in Seoul- (간선도로변 상업지역 배후 주거지의 가구배치와 상업화 특성 -서울시 강남구 테헤란로 주변 상업지역과 주거지역 사례연구 -)

  • Hong, Jae-Hong;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.229-234
    • /
    • 2005
  • The purpose of this study is to analyze a Characteristics of block formation and commercialization of residential books commercial area along urban arteries on Teheran-ro in Seoul. 'Teheran-ro' is selected as a case site to analyze the characteristics of residential blocks commercial area along urban arteries. The study analyzes the characteristics of the street network and block formation in commercial area along arteries and rear residential blocks, and commercialization of residential blocks commercial area along urban arteries according to the characteristics of street network and block formation. The analysis about block formation progress about i ) a street network and block formation, ii ) the scale of blocks, iii) division of lots, iv) lots system. The analysis about commercialization of residential blocks commercial area progress about i) a street network and block formation, ii) a density of building, iii) a use of building

  • PDF

A Study on the Behavior Properties of Residential-Commercial Building by Pushover Analysis (정적탄소성해석에 의한 복합구조물의 거동특성에 관한 연구)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.209-216
    • /
    • 2000
  • The purpose of this study is to investigate elasto-plastic behaviour and estimate ultimate resistance capacity of the residential-commercial building subjected to lateral force along the height of structure. Four types of residential-commercial building are chosen as analytical models and investigated by pushover analysis. Pushover analysis estimates initial elastic stiffness, post-yielding stiffness, and plastic hinges on each story of structures through three-dimensional nonlinear analysis program CANNY-99. Skeleton curve of bending stiffness model is bilinear, shear stiffness model is trilinear, and axial stiffness model is elastic. Skeleton curve of axial stiffness model has the axial compression and tension stiffness of reinforced concrete members. This study presents the change of inter story drift, story stiffness and hinge of story and member.

  • PDF

The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems

  • Simmonds, Peter
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.4
    • /
    • pp.311-318
    • /
    • 2015
  • The ASHRAE Design Guide for Tall, Supertall and Megatall Building Systems was produced in collaboration with the CTBUH. The design guide outlines various tall building mechanical systems that are presently being designed or are planned for the future. Tall commercial buildings in particular present a series of design problems that set them apart from other functions. The Design Guide will be of interest to owners, architects, structural engineers, mechanical engineers, electrical engineers and other specialized engineers and consultants. This design guide addresses design issues for tall commercial buildings, which are very often mixed-use, and commonly consist of low level retail, office floors, residential units, and hotel uses.

Analysis of fires case through on-field survey of residential and commercial building in Ulsan (울산 주상복합건물 현장조사를 통한 화재사례 분석)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.84-85
    • /
    • 2021
  • The fire that broke out in a residential and commercial complex in Ulsan in October 2020 was large, but no deaths occurred. For this reason, there was a difference from the previous cases, so it was analyzed through field survey. The fire was expanded to the entire building by aluminum composite panels constructed by external heat method and SMC panels in evacuation safety zones, and fire was expanded to nearby mart due to wind on the day of the fire, and there were many evacuation spaces such as 15th, 28th, and rooftop heliports.

  • PDF

Performance Evaluation of Electrochromic Window System by Different Orientations and Locations in Korea (Electrochromic 창호 적용시 지역별 건물 냉난방 에너지 소비량 절감성능)

  • Shin, Jae-Yoon;Chae, Young Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.75-84
    • /
    • 2018
  • The most crucial point of reducing building energy is application of high performance envelope. The amount of heat exchange through window is highest in comparison of other envelopes so that heat exchange through window influence directly with building energy consumption. The window energy performance can be define with thermal, leakage and optical performance. In previous study we can confirmed that not only thermal performance but also optical performance are considered, 11% to 15% of building energy consumption can be reduced. Smart window system has potential of energy saving so that many industry field use smart window system including architectural area and these aspect causes smart window market continuous growth year by year. In this study, building energy consumption has been analyzed which consist of smart window that dynamically control optical states. The consideration of standard commercial building model for research, the reference medium size commercial building model of DOE (Department Of Energy, USA) has been used. The building energy simulation result of 4 axis in 8 regions in Korea shows 8% to 22% reduction of building energy consumption by application of smart window system.

The Spatial Performance of Multi-Level Shopping Clusters A Case Study of Nanshan Commercial Cultural District

  • Haofeng, Wang;Yupeng, Zhang;Xiaojun, Rao
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.149-163
    • /
    • 2017
  • With the intensification of urban development in Chinese cities, mixed land use in urban centers extends vertically into 3-D and expands its scale from a single building to commercial clusters. The multi-level pedestrian system in city centers also changed its role from one of traffic isolation to spatial integration, where transit nodes, street sidewalks, squares, building entrances, atriums, and corridors are interconnected, both horizontally and vertically, into a whole spatial system, within which pedestrian flows are guided and shopping facilities are arranged. This paper uses spatial configuration analysis of space syntax to examine the impacts of spatial patterns on movement distribution and the business performance of tenant mix in the multi-level commercial system of the Nanshan Commercial Cultural District in Shenzhen, China. The key objective is to better understand the interactions between the socio-economic variables and spatial design parameters of a shopping complex. The research findings point to the importance of multiplicity between syntactic variables and other spatial variables in influencing the pedestrian flows, business performance and tenant mix in highly complex commercial systems. Particularly noteworthy is the relationship between spatial accessibility measures and the location of escalators, and the ways in which individual commercial buildings are embedded into the overall spatial system. The study suggests that this may lead to the preliminary identification of the spatial qualities of effective vertical extensions of mixed land use in a high-density urban settings.

An Investigation of the Building-use Changes of Residential and Commercial Areas in the Land-used Superblocks in Seoul (서울시 대가구 주거지역의 상업화·업무화와 상업지역의 주거화 현상의 고찰)

  • Jun, Jinbu;Yang, Woohyun
    • Journal of the Korean housing association
    • /
    • v.26 no.6
    • /
    • pp.127-137
    • /
    • 2015
  • This investigation is to question as to whether and how much urban residential superblocks have changed the uses of facilities, as compared with original zoning plan. The difference between the original plan for 'land use' in 1960's and current 'building uses' has been examined on six superblocks in Seoul, and the reasons for change were analyzed. Investigation results are as follows: As the original urban planning was intended for use-purification by the subdivision of zones in a superblock through zoning, current buildings uses are different from the land-use. Commercial facilities are located in residential zone along community paths because of the necessity, and business buildings are placed on the appropriate-sized lots in the middle of residential blocks, due to the need of small and low-rent offices. Also, different types of residence have been built on convenient locations in commercial zone to meet various housing needs. In conclusion, the current zoning system plays a role of controling the volume of buildings rather than the use of land. Therefore, mixed use of land, not functional separation, becomes a natural phenomenon taken place in the contemporary cities, and it is high time to adopt a mixed-use zoning system.