• Title/Summary/Keyword: comfort space

Search Result 375, Processing Time 0.023 seconds

Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) (개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가)

  • 최익순;정광섭;박영철;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

Analysis of Thermo Environment Change by Introduction of Indoor Water Space (실내 수공간 도입에 따른 온열 환경 변화 분석)

  • Oh, Sang Mok;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.

An Evaluation of Human Thermal Comfort and Improvement of Thermal Environment by Spatial Structure (공간 구조별 열쾌적성 평가와 열환경 개선방안)

  • Lee, Jung-A;Jung, Dae-Young;Chon, Jin-Hyung;Lee, Sang-Moon;Song, Young-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5
    • /
    • pp.12-20
    • /
    • 2010
  • The purpose of this study is to evaluate human thermal comfort by spatial structure and to explore solutions to improve the thermal environment of a small urban space. The study site was Korea University campus. Thermal conditions were measured to evaluate the quality of the thermal environment in each type of space within the study site. Micrometeorology measurements, analysis of space characteristics for using fish-eye lens photography, and thermal comfort modeling through the use of collected meteorological data, such as temperature and humidity, were performed. Results showed that the level of thermal comfort for humans differs depending on the types of space within the study site. Thermal comfort is better in open spaces than enclosed in the aspect of radiative mean temperature, Predicted Mean Vote(PMV), and Physiologically Equivalent Temperature(PET). This fact is probably due to shadows or buildings or trees that may block solar radiation. Thus, it is necessary to consider the spatial arrangements of buildings and trees to enhance openness and ventilation in the space. Paving materials and exterior building materials should also be selected to lower the radiant temperature. Given these results, a quantitative evaluation on human thermal comfort could propose a way to plan user comfortable small urban spaces. Study methods used and results provided in the study can promote a better way for urban space planning direction to improve environmental quality.

Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space (주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가)

  • Seok, Ho-Tae;Kim, Dong-Woo;Yang, Jeong-Hoon
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

Analysis on Thermal Environment in the Rotunda of New National Museum of Korea (새 국립중앙박물관 로튠다에서의 열환경 분석)

  • 이승철;조영진;김두성;이재헌;김홍범
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.32-39
    • /
    • 2003
  • Thermal comfort in the Rotunda which is high wide visiting space of the new national museum of Korea has been numerically investigated in this paper. To evaluate thor-mal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that thermal comfort is satisfied at the breathing zone of the visiting space. However a thermal stratification with $9^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse. For example, the PPD value reaches up to 50% in the 6th floor connection passage. Consequently, additional HVAC design factors should be considered in order to reduce the large thermal stratification.

Effect of the Vertical Air Circulation on the Thermal "Environment in a Large Space (대공간 열환경 특성에 관한 수직순환기류의 영향)

  • 김경환;강석윤;최충현;조영진;이재헌;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.581-588
    • /
    • 2000
  • This paper describes the effect of vertical air circulation on the thermal environment in an airport passenger terminal with induced flow by jet fans. In comparing the level of thermal comfort at the breathing line of 1.5 m in height, the results from the two models with or without the vertical air circulation, show that the average PPD is 8% in the former and 23% in the latter, respectively. It is thought that vertical air circulation lends to improved thermal comfort for human in respect of ventilation in a large space.

  • PDF

A Case Study on Spatial Characteristics in Collectivehouse for the Activation of the Community - Focused on Common Space - (커뮤니티 활성화를 위한 컬렉티브하우스 공간특성 사례연구 - 공동생활공간을 중심으로 -)

  • Lee, Ha-Yeon;Moon, Jeong-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.3-12
    • /
    • 2016
  • This study analyses characteristics of space to facilitate community centering on cases of collective houses in Japan and uses the results as basic data to activate collective houses as an alternative form of housing in our country. To identify the characteristics of space for active communities with collective living space, this study conducted a theoretical examination on collective houses and housing, derived territoriality, accessibility, comfort and safety as factors of community activation and analysed various cases, and the results are presented as follows: First, territoriality is a necessary condition for formation of community, and a confined and physical space. It indicates the proper size of a space and diverse spacial areas which meet the needs of residents with the proper size and amount of space (space which can accommodate diverse generations including women, the aged and the young, flexible space which changes according to the purposes and program, space which supports leisure and hobby activities, and space which can accommodate outsiders). Second, accessibility indicates an environment which supports residents' easy use of space. As the more accessible it is, the higher the frequency of its use, spatial factors (piloti, backyards, benches and tables) should be provided, community space should be arranged in a central or decentralized way and community living space should be made for each floor. As for exits, accessibility should be considered in every way; entrances connected with community spaces, open entrances and entrances accessible from outside or individual living spaces. Third, comfort satisfies the physical and mental needs of residents through separation of floors and flows between the community and individual spaces for privacy and formation of eco-friendly spaces including vegetable gardens, gardens and plant arrangements. Fourth, safety should be considered for a higher quality environment with psychological stability and comfort, for which the following are recommended: installation of hand-rails, removal of thresholds, spacial design for the socially weak, duplex and open type structures for community space, open stages and halls, as well as indoor and outdoor openness through the use of windows.

A Study of Hospital Choice on the Basis of Consumption Values Theory (소비가치 이론에 의한 병원선택 요인 연구)

  • Lee, Sun-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.413-427
    • /
    • 1997
  • This research is based on the Consumption Values Theory proposed by Sheth(1991). The purpose of this research is finding the factors related to the process of hospital choice. The expectation of six hospital outpatients 600 was analyzed by six consumption values categories: functional value, social value, emotional value, rarity value, condition value, health related values. The main results of this research is as following; 1. In the result of factor analysis 22 consumption value factors which affect the hospital preference were extracted; kindness/clearness, service speed, comfort of space, technical competence in functional values, high income/active social life, low income/blue collar unmarried/man, middle aged/big family, woman/married, introvert in social values, high-class, comfort, reliability in emotional value, newness, classiness in rarity value, social relationship, close to residence, social reputation in conditional values, priority on health, health behavior, active sense of value on health in health related values. 2. The difference of consumption values among hospital types were analyzed. The critical factors in reference for corporate hospitals newly established were kindness/clearness, service speed, convenience, classiness, comfort, and newness. University hospitals were preferred by the factors of reliability, and social reputation. In general hospital, convenience and close to residence were critical factor. 3. In logistic regression, age, marital status, education level and income as socio-demographic variables were significantly related to general hospital choice. Also service speed and close to residence were positively and high income/active social life and high class value were negatively related to general hospital choice. On university hospital choice, age and marital status, education show posive relationship whereas income showing negative relationship. Kindness/clearness, service speed, comfort of space, unmarried/man, comfortable feeling, newness and close to residence showed negative relationship with university hospital selection whereas technical competence, reliability in emotional value, classiness in rarity value, social relationship in functional values showed positive relationship. Lastly kindness/clearness, comfort of space, high income/active social life, unmarried/man, high-class, comfort and newness were positively related to corporate hospitals newly established choice in contrast to negative relationship in reliability in emotional value and classiness. In summary, we found that hospital user also choose to hospital in base of various consumption value. Further studies to investigate the hospital consumer behavior will be needed.

  • PDF

Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea (기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가)

  • 이승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

Analyses on Comparison of UTCI, PMV, WBGT between Playground and Green Space in School (학교 운동장과 녹지공간의 UTCI, PMV, WBGT 비교 분석)

  • Yoon, Young-Han;Park, Seung-Hwan;Kim, Won-Tae;Kim, Jeong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.1
    • /
    • pp.80-89
    • /
    • 2014
  • This study of the school's outdoor space for relaxing and activity of the two most numerous students, high heat and low heat with a green space, playground targets of thermal comfort indicators UTCI, PMV, WBGT using the thermal comfort students feeling compare the analyzed. The destination of this study, school facilities of Nam-gu, Namdong- gu, Incheon were studied and the investigation period was conducted from July to August. List of measurement, in the case of thermal comfort indicators, UTCI, PMV, WBGT was measured in the case of green, ratio of green coverage and GVZ was measured. GVZ analysis were as follows: A school ($4.71m^3/m^2$) B school ($3.34m^3/m^2$) C school ($0.38m^3/m^2$). Comparative analysis of the results of thermal comfort indicators by schools, UTCI was Green space $26.15{\sim}31.38^{\circ}C$ and playground $40.66{\sim}42.94^{\circ}C$, PMV values were 1.76 to 2.66 as a green space. WBGT was Green space $26.15{\sim}31.38^{\circ}C$, playground $31.67{\sim}34.53^{\circ}C$. Comparative analysis of the results of thermal comfort indicators UTCI, PMV, WBGT all A school, B school, C school, on the green space was comfortable levels more than playground. The results of the school type thermal comfort and green correlation analysis of thermal comfort UTCI, PMV, WBGT all solar radiation, globe temperature, and a positive correlation shown solar radiation, globe temperature is not comfortable, the higher was considered. UTCI, PMV, WBGT of thermal comfort indicator all ratio of green coverage, GVZ and negative correlation appears ratio of green coverage, GVZ was increased due to the lowering of the value of thermal comfort indicators was considered to be comfortable.