• Title/Summary/Keyword: combined loads

Search Result 486, Processing Time 0.026 seconds

CANCAR - Congestion-Avoidance Network Coding-Aware Routing for Wireless Mesh Networks

  • Pertovt, Erik;Alic, Kemal;Svigelj, Ales;Mohorcic, Mihael
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4205-4227
    • /
    • 2018
  • Network Coding (NC) is an approach recently investigated for increasing the network throughput and thus enhancing the performance of wireless mesh networks. The benefits of NC can further be improved when routing decisions are made with the awareness of coding capabilities and opportunities. Typically, the goal of such routing is to find and exploit routes with new coding opportunities and thus further increase the network throughput. As shown in this paper, in case of proactive routing the coding awareness along with the information of the measured traffic coding success can also be efficiently used to support the congestion avoidance and enable more encoded packets, thus indirectly further increasing the network throughput. To this end, a new proactive routing procedure called Congestion-Avoidance Network Coding-Aware Routing (CANCAR) is proposed. It detects the currently most highly-loaded node and prevents it from saturation by diverting some of the least coded traffic flows to alternative routes, thus achieving even higher coding gain by the remaining well-coded traffic flows on the node. The simulation results confirm that the proposed proactive routing procedure combined with the well-known COPE NC avoids network congestion and provides higher coding gains, thus achieving significantly higher throughput and enabling higher traffic loads both in a representative regular network topology as well as in two synthetically generated random network topologies.

A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP (DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구)

  • Seo, Hyo-Ryong;Park, Young-Gil;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

LIFE-SPAN SIMULATION AND DESIGN APPROACH FOR REINFORCED CONCRETE STRUCTURES

  • An, Xuehui;Maekawa, Koichi;Ishida, Tetsuya
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.3-17
    • /
    • 2007
  • This paper provides an introduction to life-span simulation and numerical approach to support the performance design processes of reinforced concrete structures. An integrated computational system is proposed for life-span simulation of reinforced concrete. Conservation of moisture, carbon dioxide, oxygen, chloride, calcium and momentum is solved with hydration, carbonation, corrosion, ion dissolution. damage evolution and their thermodynamic/mechanical equilibrium. Coupled analysis of mass transport and damage mechanics associated with steel corrosion is presented for structural performance assessment of reinforced concrete. Multi-scale modeling of micro-pore formation and transport phenomena of moisture and ions are mutually linked for predicting the corrosion of reinforcement and volumetric changes. The interaction of crack propagation with corroded gel migration can also be simulated. Two finite element codes. multi-chemo physical simulation code (DuCOM) and nonlinear dynamic code of structural reinforced concrete (COM3) were combined together to form the integrated simulation system. This computational system was verified by the laboratory scale and large scale experiments of damaged reinforced concrete members under static loads, and has been applied to safety and serviceability assessment of existing structures. Based on the damage details predicted by the nonlinear finite element analytical system, the life-span-cost of RC structures including the original construction costs and the repairing costs for possible damage during the service life can be evaluated for design purpose.

  • PDF

PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method (IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구)

  • Pak, Jin-Woo;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

The Effect of Shoulder and Elbow Postures with External Loads on the Perceived Discomfort (어깨와 팔꿈치의 조합자세 및 외부부하가 지각불편도에 미치는 영향)

  • Kim, Dong-Jin;Na, Seok-Hee;Park, Guk-Mu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.145-151
    • /
    • 2006
  • The objective of this study is to investigate the perceived discomfort for postures combined with shoulder flexion/extension and elbow flexion, and external load. 12 healthy male undergraduate and graduate students participated in this experiment. Experimental variables were the shoulder flexion/extension angle(-20°, 0°, 45°, 90°, 135°), the elbow flexion angle (0°, 45°, 120°), and the external load(0, 1.5Kg, 3Kg) as independent variables and a whole body perceived discomfort using Borg's CR10 as a dependent variable. The subjects maintained the given posture for 60 seconds and then rated the perceived discomfort. The ANOVA results showed that all main factors and two-way interactions were statistically significant at α=0.05. As a result of regression analysis to examine the effect of external load on the perceived discomfort, the perceived discomfort linearly increased as the level of external load increased. Then, the effect of external load on the perceived discomfort was quantitatively classified into three levels based on the result of regression analysis.

Basic Design of Deep Subsea Manifold Frame Structure for Oil Production (심해저 원유 생산용 매니폴드 프레임 구조 기본 설계)

  • Park, Se-Yung;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.207-216
    • /
    • 2015
  • Amanifold is one of the essential subsea oil and gas production components to simplify the subsea production layout. It collects the production fluid from a couple of wellheads, transfers it to onshore or offshore storage platforms, and even accommodates water and gas injection flowlines. This paper presents the basic design procedure for a manifold frame structure with novel structural verification using in-house unity check codes. Loads and load cases for the design of an SIL 3 class-manifold are established from a survey of relevant industrial codes. The basic design of the manifold frame is developed based on simple load considerations such as the self weights of the manifold frame and pipeline system. In-house software with Eurocode 3 embedded, called INHA-SOLVER, makes it possible to carry out code checks on the yield and buckling unities. This paper finally proves that the new design of the manifold frame structure is effective to resist a permanent and environment load, and the in-house code is also adaptively combined with the commercial finite element code Nastran.

Experimental and numerical analysis of fatigue behaviour for tubular K-joints

  • Shao, Yong-Bo;Cao, Zhen-Bin
    • Structural Engineering and Mechanics
    • /
    • v.19 no.6
    • /
    • pp.639-652
    • /
    • 2005
  • In this paper, a full-scale K-joint specimen was tested to failure under cyclic combined axial and in-plane bending loads. In the fatigue test, the crack developments were monitored step by step using the alternating current potential drop (ACPD) technique. Using Paris' law, stress intensity factor, which is a fracture parameter to be frequently used by many designers to predict the integrity and residual life of tubular joints, can be obtained from experimental test results of the crack growth rate. Furthermore, a scheme of automatic mesh generation for a cracked K-joint is introduced, and numerical analysis of stress intensity factor for the K-joint specimen has then been carried out. In the finite element analysis, J-integral method is used to estimate the stress intensity factors along the crack front. The numerical stress intensity factor results have been validated through comparing them with the experimental results. The comparison shows that the proposed numerical model can produce reasonably accurate stress intensity factor values. The effects of different crack shapes on the stress intensity factors have also been investigated, and it has been found that semi-ellipse is suitable and accurate to be adopted in numerical analysis for the stress intensity factor. Therefore, the proposed model in this paper is reliable to be used for estimating the stress intensity factor values of cracked tubular K-joints for design purposes.

The effects of topography on local wind-induced pressures of a medium-rise building

  • Hitchcock, P.A.;Kwok, K.C.S.;Wong, K.S.;Shum, K.M.
    • Wind and Structures
    • /
    • v.13 no.5
    • /
    • pp.433-449
    • /
    • 2010
  • Wind tunnel model tests were conducted for a residential apartment block located within the complex terrain of The Hong Kong University of Science and Technology (HKUST). The test building is typical of medium-rise residential buildings in Hong Kong. The model study was conducted using modelling techniques and assumptions that are commonly used to predict design wind loads and pressures for buildings sited in regions of significant topography. Results for the building model with and without the surrounding topography were compared to investigate the effects of far-field and near-field topography on wind characteristics at the test building site and wind-induced external pressure coefficients at key locations on the building facade. The study also compared the wind tunnel test results to topographic multipliers and external pressure coefficients determined from nine international design standards. Differences between the external pressure coefficients stipulated in the various standards will be exacerbated when they are combined with the respective topographic multipliers.

Dynamic increase factor for progressive collapse analysis of semi-rigid steel frames

  • Zhu, Yan Fei;Chen, Chang Hong;Yao, Yao;Keer, Leon M.;Huang, Ying
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.209-221
    • /
    • 2018
  • An empirical and efficient method is presented for calculating the dynamic increase factor to amplify the applied loads on the affected bays of a steel frame structure with semi-rigid connections. The nonlinear static alternate path analysis is used to evaluate the dynamic responses. First, the polynomial models of the extended end plate and the top and seat connection are modified, and the proposed polynomial model of the flush end plate connection shows good agreement as compared with experimental results. Next, a beam model with nonlinear spring elements and plastic hinges is utilized to incorporate the combined effect of connection flexibility and material nonlinearity. A new step-by-step analysis procedure is established to obtain quickly the dynamic increase factor based on a combination of the pushdown analysis and nonlinear dynamic analysis. Finally, the modified dynamic increase factor equation, defined as a function of the maximum ratio value of energy demand to energy capacity of an affected beam, is derived by curve fitting data points generated by the different analysis cases with different column removal scenarios and five types of semi-rigid connections.

Seismic behavior of steel tube reinforced concrete bridge columns

  • Tian, Tian;Qiu, Wen-liang;Zhang, Zhe
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.63-71
    • /
    • 2018
  • This paper reports an experimental study that was accomplished to assess the seismic behavior of steel tube reinforced concrete bridge columns (SBCs). The motivation of this study was to verify a supposition that the core steel tube may be terminated at a rational position in the column to minimize the material cost while maintaining the seismic behavior of this composite column. Four SBC specimens were tested under combined constant axial load and cyclic reversed lateral loads. The unique variable in the test matrix was the core steel tube embedment length, which ranged from 1/3 to 3/3 of the column effective height. It is observed that SBCs showed two distinctly different failure patterns, namely brittle shear failure and ductile flexural failure. Tests results indicate that the hysteretic responses of SBCs were susceptible to the core steel tube embedment length. With the increase of this structural parameter, the lateral strength of SBC was progressively improved; the deformability and ductility, however, exhibited a tendency of first increase and then decrease. It is also found that in addition to maintained the rate of stiffness degradation and cumulative energy dissipation basically unchanged, both the ductility and deformability of SBC were significantly improved when the core steel tube was terminated at the mid-height of the column, and these were the most unexpected benefits accompanied with material cost reduction.