• Title/Summary/Keyword: combined generation system

Search Result 362, Processing Time 0.038 seconds

Measurement of local wind and solar radiation for a hybrid power generation system design, Busan, Korea

  • Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.799-806
    • /
    • 2013
  • As a first step to develop the hybrid power generation system, on this study, the time-variable resources of wind and solar radiation of Yeongdo, Busan, Korea had been measured during June and July 2013. And the quantity of generated wind power and solar photovoltaic had also been measured during the same period. It is found out that the wind mainly flew from southwest at the average speed of 2 m/s during 2 months. And it is clear that, because of the low wind velocity, the wind quality to generate the power seems not enough at this area. Meanwhile solar radiation was measured every daytime (6:00~19:00) and the peak solar radiation occurred around 12:00~14:00. And it is clear that the time-based variations of quantity of generated power were proportional to the variations of these resources, respectively. As a proposal, these 2 natural energies can be combined as resources of a hybrid system, because these 2 patterns are not overlapped so much on time base.

Probabilistic Analysis of JPV Prime Generation Algorithm and its Improvement (JPV 소수 생성 알고리즘의 확률적 분석 및 성능 개선)

  • Park, Hee-Jin;Jo, Ho-Sung
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.2
    • /
    • pp.75-83
    • /
    • 2008
  • Joye et al. introduced a new prime generation algorithm (JPV algorithm hereafter), by removing the trial division from the previous combined prime generation algorithm (combined algorithm hereafter) and claimed that JPV algorithm is $30{\sim}40%$ faster than the combined algorithm. However, they only compared the number of Fermat-test calls, instead of comparing the total running times of two algorithms. The reason why the total running times could not be compared is that there was no probabilistic analysis on the running time of the JPV algorithm even though there was a probabilistic analysis for the combined algorithm. In this paper, we present a probabilistic analysis on the running time of the JPV algorithm. With this analytic model, we compare the running times of the JPV algorithm and the combined algorithm. Our model predicts that JPV algorithm is slower than the combined algorithm when a 512-bit prime is generated on a Pentium 4 system. Although our prediction is contrary to the previous prediction from comparing Fermat-test calls, our prediction corresponds to the experimental results more exactly. In addition, we propose a method to improve the JPV algorithm. With this method, the JPV algorithm can be comparable to the combined algorithm with the same space requirement.

The Basic Study on Economic Evaluation of Distributed Energy System Installed in Hospital (병원건물 분산에너지시스템 도입에 따른 경제성분석)

  • Hong, Won-Pyo;Kim, Hyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1136_1138
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that burn gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

The Basic Study on Economic Evaluation of Micro-turbine and Alternative Energy system Installed in Hospital (병원건물의 마이크로터빈과 신재생에너지도입에 따른 경제성평가 기초연구)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.439-444
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of. solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

A Study on the Optimal Solar Power System for 10kW Wind Power in the Mokpo Seaside (목포해안지역의 10kW급 풍력과 최적의 태양광 복합발전시스템에 관한 연구)

  • Cho, Dong-Hoon;Bae, Cherl-O;Park, Young-San
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.1 s.28
    • /
    • pp.69-73
    • /
    • 2007
  • As the interest in environmental pollution increases, the use of renewable energy is uprising. Among the renewable energy resources, wind and solar energy have no environmental impact and they can be used as unlimited resources. The two power systems are mutual supplementary systems. So the two systems are usually combined for generation. We have measured several data about wind and solar. These data can be used the foundation data for the construction of wind and solar power generation plants. Also we analyzed the possible optimal solar power system for 10[kW] wind power.

  • PDF

A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP (DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구)

  • Seo, Hyo-Ryong;Park, Young-Gil;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

Rich Transcription Generation Using Automatic Insertion of Punctuation Marks (자동 구두점 삽입을 이용한 Rich Transcription 생성)

  • Kim, Ji-Hwan
    • MALSORI
    • /
    • no.61
    • /
    • pp.87-100
    • /
    • 2007
  • A punctuation generation system which combines prosodic information with acoustic and language model information is presented. Experiments have been conducted first for the reference text transcriptions. In these experiments, prosodic information was shown to be more useful than language model information. When these information sources are combined, an F-measure of up to 0.7830 was obtained for adding punctuation to a reference transcription. This method of punctuation generation can also be applied to the 1-best output of a speech recogniser. The 1-best output is first time aligned. Based on the time alignment information, prosodic features are generated. As in the approach applied in the punctuation generation for reference transcriptions, the best sequence of punctuation marks for this 1-best output is found using the prosodic feature model and an language model trained on texts which contain punctuation marks.

  • PDF

Comparison of the operational characteristics of the PV-AF system according to the various MPPT controls (액티브필터 기능을 가진 태양광발전시스템(PV-AF 시스템)의 MPPT제어법에 따른 출력특성비교)

  • Park, Min-Won;Kim, Bong-Tae;Lee, Jae-Deuk;Seong, Ki-Chul;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.325-327
    • /
    • 2001
  • So far, because the photovoltaics power generation system can be treated to a harmonics source for the power distribution systems, the PV system combined the function of AF systems as well as the AF systems using the PV module as the power source have never been reported. However, authors have recently proposed a novel concept of the photovoltaics power generation system adding the function of the active filter (PV-AF system). In this paper, in order to confirm the operational characteristics of the PV-AF system, various MPPT controls are applied and analyzed.

  • PDF

Scheduling of Combined Cycle Gas Turbine Using Lagrangian Relaxation Method (Lagrangian Relaxation 법을 이용한 복합 화력 발전기의 기동 정지 계획)

  • Nam, Young-Woo;Park, Jong-Keun;Kim, Sung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.334-336
    • /
    • 2000
  • In Korea, the CCGTs have been installed to about 25% of the total generating capacity. Generally CCGTs determine the System Marginal Prices(SMP) in Cost Based Generation Pool. So the scheduling of CCGTs is very important in daily generation scheduling. This paper describes the scheduling of CCGTs which considers the operating characteristics of them. We use lagrangian relaxation method which decomposes the unit committment problem into the subproblems of the individual unit. In the CCGT subproblem, we define the cost function of CCGT in two way. In Case study, the daily generation scheduling is performed using the data of Korean thermal system.

  • PDF