• 제목/요약/키워드: combined energy

검색결과 1,926건 처리시간 0.03초

공냉-수냉 혼합냉각계통 개발 (Development of an Air-Water Combined Cooling System)

  • 권태순;배성원
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.84-88
    • /
    • 2014
  • A long term passive cooling system is considered as the most important safety feature for the nuclear design after the Fukushima Daiichi nuclear power plant accident in 2011. The conventional active pump driven safety systems are not available during a station Black Out (SBO) accident. The current design requirement on cooling time of the Passive Auxiliarly Feedwater System (PAFS) is about 8 hours only. To meet the 72 hours cooling time, the pool capacity of cooling water tank should be increased as much as 3~4 times larger than that of current water cooling tank. In order to extend the cooling time for 72 hours, a new passive air-water combined cooling system is proposed. This paper provides the feasibility of the combined passive air-water cooling system. The current pool capacity of water cooling system is preserved, and the cooling capability is extended by an additional air cooler.

유기랭킨사이클을 이용한 직렬 열병합 사이클의 성능 특성 (Performance Characteristics of Combined Heat and Power Generation with Series Circuit Using Organic Rankine Cycle)

  • 김경훈;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.699-705
    • /
    • 2011
  • A combined heat and power cogeneration system driven by low-temperature sources is investigated by the first and second laws of thermodynamics. The system consists of Organic Rankine Cycle (ORC) and an additional process heater as a series circuit. Seven working fluids of R152a, propane, isobutane, butane, R11, R123, isopentane and n-pentane are considered in this work. Maximum mass flow rate of a working fluid relative to that of the source fluid is considered to extract maximum power from the source. Results indicate that the second-law efficiency can be significantly increased due to the combined heat and power generation. Furthermore, higher source temperature and lower turbine inlet pressure lead to lower second-law efficiency of ORC system but higher that of combined system. Results also show that the optimum working fluid varies with the source temperature.

Aspergillus flavus 및 Penicillium islandicum의 방사선(放射線) 감수성(感受性)에 미치는 병용(倂用)처리의 효과(效果) (Effects of Combined Treatments on the Radiosensitivity of Aspergillus flavus and Penicillium islandicum)

  • 최언호;이서래
    • 한국식품과학회지
    • /
    • 제7권3호
    • /
    • pp.154-158
    • /
    • 1975
  • Mycotoxin 생성균(生成菌)인 Aspergillus flavus 와 Penicillium islandicum 분생포자(分生胞子)의 생존(生存)에 미치는 방사선과 가열 또는 약품의 병용(倂用)처리효과를 실험하여 다음과 같은 결과를 얻었다. 감마선과 가열($50^{\circ}C$ 또는 $55^{\circ}C$에서 10분 처리)의 병용처리는 두 곰팡이에서 현저한 상승효과(相乘效果)를 보여 $D_{10}$값과 유도선량(誘導線量)이 크게 감소하였으나 방사선과 약품(sorbic acid)의 병용처리는 아무런 상승효과도 보이지 아니하였다. Asp. flavus 는 Pen. islandicum 에 비하여 가열 및 sorbic acid 에 대한 저항성이 더 컸다.

  • PDF

지열원 및 수열원 비율에 따른 복합열원 히트펌프시스템 성능 평가 연구 (A Study on the Performance Evaluation of Combined Heat Pump System according to the Ratio of Ground Heat Source and Water Heat Source)

  • 박시훈;고유진;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.11-19
    • /
    • 2021
  • In this study, combined heat source heat pump system was implemented with 4 single heat source heat pumps each applied with a geothermal source and a water source. Five cases (Case1~Case5) were configured to conduct a performance comparison and analysis of the combined heat source heat pump system. First of all, as a result of analyzing the heat source, the case when 4 ground heat sources were applied (Case1) showed a uniform EST(Entering Source Temperature) distribution throughout the year since it is less affected by outside air compared to the case when 4 water heat sources were applied (Case5). In both winter and summer, the ground heat source maintained higher EST than the water heat source. Therefore, the system with high ratio of geothermal sources is advantageous for heating, and with high ratio of water heat sources is advantageous for cooling.

지역난방 규모에 따른 열병합발전플랜트의 경제적 최적용량 선정에 관한 연구 (A Study on the Optimum Capacity of Combind Heat & Power Plant Related to Size of District Heating System)

  • 정찬교;김훈
    • 에너지공학
    • /
    • 제9권2호
    • /
    • pp.95-101
    • /
    • 2000
  • The purpose of this study is to find plant utilities capacity for economical operation of combined heat & power by reducing energy expenditure. Using a numerical simulation program CHPSIM, a comparative analysis of additional heat expenditure (AHE) of combined heat & power plant in relation to size of district heating has been performed within the comparison of the difference capacity of gas turbine and steam turbine . As a results, if a 105.2MW gas turbine (exhaust gas temp ; 540$^{\circ}C$) installed in CHP plant can reduced 17-18% yearly the AHE than 75MW gas turbine (520$^{\circ}C$) installed. If a 130-150MW gas turbine (560-580$^{\circ}C$) installed, can reduced 34.7-35.8% of the yearly AHE.

  • PDF

Theoretical Study for Hydrogen Production from an Integrated Gasification Combined Cycle System

  • Lee, Sang-Sup
    • Environmental Engineering Research
    • /
    • 제16권1호
    • /
    • pp.35-39
    • /
    • 2011
  • An integrated gasification combined cycle (IGCC) system has been attracting attention due to its increased energy conversion efficiency and ability to treat various carbonaceous materials. IGCC is also expected to play an important role in the future supply of hydrogen energy. The use of a palladium-based membrane to separate the hydrogen from the synthesis gas stream has been intensively studied due to its exceptional hydrogen-separating capability. However, theoretical research on hydrogen separation is still an unfamiliar area in Korea. First-principle density functional theory was applied in this study to investigate the dissociative adsorption of hydrogen onto a palladium surface. The stability of hydrogen on the surface was theoretically evaluated with various adsorption configurations, partial pressures and temperatures. Further theoretical and experimental studies were also suggested to find a more hydrogen-selective material.

Advanced Railway Power Quality Detecting Algorithm Using a Combined TEO and STFT Method

  • Yoo, Je-Ho;Shin, Seung-Kwon;Park, Jong-young;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2442-2447
    • /
    • 2015
  • Because an electric railway vehicle is a large scale moving load, it can cause various kinds of power quality problems in the railroad power system. The power quality impacts are considered as the strong instantaneous stresses to the related power systems and can cause an accelerating aging and a malfunction of the power supplying components. Therefore, it is necessary to detect the small and intermittent symptoms mixed in the voltage waveform. However, they cannot be detected by the triggering functions of the existing power analyzers installed in the railway systems. This paper will examine the drawback of some fast detection tools and propose an advanced detecting and analyzing method based on a combined TEO and STFT algorithm.

Vibration-based damage detection in beams using genetic algorithm

  • Kim, Jeong-Tae;Park, Jae-Hyung;Yoon, Han-Sam;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • 제3권3호
    • /
    • pp.263-280
    • /
    • 2007
  • In this paper, an improved GA-based damage detection algorithm using a set of combined modal features is proposed. Firstly, a new GA-based damage detection algorithm is formulated for beam-type structures. A schematic of the GA-based damage detection algorithm is designed and objective functions using several modal features are selected for the algorithm. Secondly, experimental modal tests are performed on free-free beams. Modal features such as natural frequency, mode shape, and modal strain energy are experimentally measured before and after damage in the test beams. Finally, damage detection exercises are performed on the test beam to evaluate the feasibility of the proposed method. Experimental results show that the damage detection is the most accurate when frequency changes combined with modal strain-energy changes are used as the modal features for the proposed method.

복합화력발전설비와 지역난방설비가 연계된 종합열병합발전시스템의 일간 최적운전계획 수립 (A Daily Optimal Operation Scheduling of Total Cogeneration System Operating by Combined Heat Power Plant and District Heat Devices)

  • 정지훈;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.183-186
    • /
    • 2001
  • This paper describes the optimal operation scheduling of total cogeneration system which is interconnected with combined heat power plant of utility and district heat devices. The numerical modeling about the cogeneration system and the auxiliary thermal energy devices are established and simulation is carried out by LINDO program in order to minimize the operation cost under the national viewpoint. The results reveal that the established numerical modeling and the operation strategy can be effectively applied to the total cogeneration systems to reduce the energy cost.

  • PDF

복합화력발전소의 냉각수 배열회수를 위한 히트펌프의 성능평가 (Analysis on the Performance Test Results of Heat Pump for the Closed Cooling Water Heat Recovery on Combined Thermal Power Plant)

  • 이성호
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.43-48
    • /
    • 2016
  • This study proves successes of Energy Service Company (ESCO) business by heat pump performance test. The purpose of ESCO business is recover investment costs through saving energy from installation of energy reduction facility. The most important technology assessment items are heat recovery and generator output. Experimental result shows that increase quality of heat recovery (11.52Gcal/h), while decrease generator output (0.234kw). In its final analysis, the ESCO business is successful according to our data.