• Title/Summary/Keyword: combined electric power generation system

검색결과 48건 처리시간 0.033초

듀얼 인버터 개방 권선형 영구자석 동기 전동기 제어를 위한 PWM 가변 캐리어 생성법 및 영벡터 위치에 따른 전류 리플 분석 (PWM Variable Carrier Generating Method for OEW PMSM with Dual Inverter and Current Ripple Analysis according to Zero Vector Position)

  • 심재훈;최현규;하정익
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.279-285
    • /
    • 2020
  • An open-end winding (OEW) permanent magnet synchronous motor with dual inverters can synthesize large voltages for a motor with the same DC link voltage. This ability has the advantage of reducing the use of DC/DC boost converters or high voltage batteries. However, zero-sequence voltage (ZSV), which is caused by the difference in the combined voltage between the primary and secondary inverters, can generate a zero-sequence current (ZSC) that increases system losses. Among the methods for eliminating this phenomenon, combining voltage vector eliminated ZSV cannot be accomplished by the conventional Pulse Width Modulation(PWM) method. In this study, a PWM carrier generation method using functionalization to generate a switching pattern to suppress ZSC is proposed and applied to analyze the control influence of the center-zero vector in the switching sequence about the current ripple.

다중 물 분사 노즐이 장착된 감온밸브의 해석 연구 (An Analysis Study on Desuperheater valve attachment on Multi Water Spray Nozzles)

  • 이덕구;조행훈;조남철;이채문
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2009
  • The generation of electric power and plant facilities have been attempting to improve energy efficiency with many efforts as those being basis of our country's economy. In particular, the CHP(Combined Heat Power plant) system, is producing the electricity and process steam, has generally been using for the cogeneration plants. When CHP system operates, the steam has to maintain the high temperature and high pressure in order to have high efficiency of electric power production as much as possible. In addition, the exhausted steam from the turbine has to reform proper temperature to use the needed process. The major purpose of desuperheater is that the superheated steam changes into the saturated steam because it is more efficient and suitable for using the process, furthermore, it is more convenient and stable regarding the process temperature control. The design of the desuperheater obtained through the experiment and preceding analysis. This paper is verified by analysis that water spray nozzle(${\Phi}$=28mm) shows the best ability under the real power plant condition.

  • PDF

Shell 석탄가스화 복합발전 시스템의 성능해석 연구 (Performance Analysis of Shell Coal Gasification Combined Cycle systems)

  • Kim, Jong-Jin;Park, Moung-Ho;Song, Kyu-So;Cho, Sang-Ki;Seo, Seok-Bin;Kim, Chong-Young
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.104-113
    • /
    • 1997
  • 본 연구에서는 상용공정모사기인 ASPEN PLUS를 이용하여 건식탄공급, 산소사용 분류층 가스화기인 Shell가스화공정, 저온가스정제공정, GE MS7001FA가스터빈, 삼압.자연순환식 폐열회수보일러, 재열복수식 증기터빈 및 극저온 산소분리공정을 채용한 IGCC시스템에 대하여 성능해석 모델을 개발하고 시스템 성능해석을 위한 민감도분석을 수행하였다. 본 모델의 적정성은 설계조건에서 대상탄을 이용한 정상상태 성능해석 결과를 타 시뮬레이션 결과와 비교함으로서 검증하였다.$^{1)}$ . Illinois#6탄을 대상으로 수행한 시뮬레이션 결과는 투입되는 탄에 함유된 수분의 양이 증가함에 따라 가스화기의 온도가 감소하며, 회분 및 황이 많은 경우에 현열손실이 증가하여 시스템 효율이 감소하였다. 개발된 모델을 이용하여 가스화기의 운전압력, 증기/석탄비율 및 산소/석탄비율에 따르는 시스템의 민감도분석을 수행한 결과 운전압력 증가에 따라 가스화기 노내온도가 상승하며, 가연성가스(CO+H2) 생성율이 감소하였다. 증기/석탄비율 변화분석에서는 공급증기의 양을 변화시키면 가연성가스의 최고생성점이 보다 낮은 산소/석탄비율에서 나타남을 알 수 있었다. 또한 산소/석탄비율 변화분석에서는 증기/석탄 공급비율 0.2에서 산소/석탄 공급비율이 0.77인 경우에 가장 최적의 운전조건임을 알 수 있었다.

  • PDF

탄소세(炭素稅)를 고려한 화력발전 설비간의 경제성 평가 (Economic Analysis of Power Plant Utilities Under $CO_2$ Emission Tax)

  • 김지수;이병남;김태진
    • 산업공학
    • /
    • 제10권1호
    • /
    • pp.237-248
    • /
    • 1997
  • The purpose of this study is to make an economic analysis of power plant utilities by examining electricity generating costs with environmental consideration. Economic growth has caused pollutant emission, and subsequent environmental pollution has been identified as a very real limit to sustainable development. Considering the enormous role of electricity in the national economy, it is thus very important to study the effect of environmental regulations on the electricity sector. Because power utilities need large investments during construction, operation and maintenance, and also require much construction lead time. Economic analysis is the very important process in the electric system expansion planning. In this study, the levelized generation cost method is used in comparing economic analysis of power plant utilities. Among the pollutants discharged of the electricity sector, this study principally deals with the control activities related only to $CO_2$, and $NO_2$, since the control cost of $SO_2$, and TSP (Total Suspended Particulates) is already included in the construction cost of utilities. The cost of electricity generation in a coal-fired power plant is compared with one in an LNG combined cycle power plant. Moreover this study surveys the sensitivity of fuel price, interest rate and carbon tax. In each case, this sensitivity can help to decide which utility is economically justified in the circumstance of environmental regulations.

  • PDF

축산폐기물 BIO-ENERGY를 이용한 분산형 마이크로 가스터빈 발전기술 개발 (Development of Distributed Micro Gas Turbine(MGT) Technology by using Swine BID-ENERGY)

  • 허광범;박정극;이정빈;임상규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.463-466
    • /
    • 2005
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection constrains. KEPOD (Korea Electric Power Corporation) is performing the project to develope the Distributed Micro Gas Turbine (MGT) technologies by using Swine BID-ENERGY. This paper describes the plans and strategies for the renewable energy of MGT on actual grid-connection under Korean situations. KEPOD also, has a research plan on bio-gas pretreatment system applicable to our domestic swine renewable resources and is performing concept design of pilot plant to test grid operation. In addition, this testing will be conducted in order to respond to a wide variety of needs for application and economic evaluation in the field of On-site generation.

  • PDF

환경요소를 고려한 발전설비의 경제성 평가 (Economic Analysis of Plant Utilities Under Environment Factor)

  • 정석재;김경섭;박진원
    • 한국시뮬레이션학회논문지
    • /
    • 제13권2호
    • /
    • pp.35-43
    • /
    • 2004
  • The purpose of this study is an economic analysis of power plant utilities by comparing electricity generating cost including environmental costs. Considering the enormous role of electricity in the national economy, it is very important to study the effect of environmental regulation on the electricity sector. Because power utilities need for large investment during construction, operation and maintenance, and also require much construction lead time. Economic analysis is the important process in the electric system expansion planning. This paper compares the costs of electricity generation including environmental costs between a coal-fired power plant and an LNG combined cycle power plants. With the simulation, this study surveys the sensitivity of fuel prices, interest rate and carbon tax. In each case, this sensitivity can help to decide which utility is economically better in environmental regulation circumstance.

  • PDF

120MW급 열병합 복합발전시스템의 열역학적 효율 특성 (The thermodynamic efficiency characteristics of combined cogeneration system of 120MW)

  • 최명진;김홍주;김병헌
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.29-36
    • /
    • 2017
  • 본 논문은 열병합 복합발전이란 하나의 프로세스에서 전기 또는 기계 동력과 열에너지의 두 형태를 생산하는 것이다. 가스터빈 열병합 발전 시스템의 각 구성부의 성능을 변수로 전체 시스템의 연료 소모와 각 구성부의 열과 전기의 성능을 표현하여야 한다. 전체시스템은 상부 시스템인 가스터빈 2대와 하부시스템인 열회수 증기발생기(HRSG) 2대, 증기터빈 1대, 지역난방열교환기 2대로 구성되어 있다. 가스터빈 열병합 복합발전시스템에서 가동시간 기준 10,000시간 후 성능시험을 각종 시험장치 설치 및 ASME PTC 46에 준한 성능시험으로 실시하였고, 발전소 전체의 종합출력과 효율에 대한 성능을 분석하였다. 이러한 성능시험 실시자료를 기초로 시험성능을 비교하여 성능변화 값을 확인하였다. 이 논문에서 가스터빈, 열회수 증기발생기, 증기터빈의 열역학적 시스템 해석을 통하여 이론적 결과 값을 산출하였다. 비교 대상은 전체 시스템의 생산열량과 대기로 배출되는 열량을 이론값과 실험값을 비교하였고, 전기출력 및 열 출력에 대한 효율을 이론값과 실제 값을 비교하였다. 가스터빈 열병합 복합발전소 성능 특성에 대한 시험결과를 열역학적 효율 특성과 비교하였으며, 0.3%의 오차를 보였다.

Modeling of Solar/Hydrogen/DEGS Hybrid System for Stand Alone Applications of a Large Store

  • Hong, Won-Pyo
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.57-68
    • /
    • 2013
  • The market for distributed power generation based on renewable energy is increasing, particularly for standalone mini-grid applications in developing countries with limited energy resources. Stand-alone power systems (SAPS) are of special interest combined with renewable energy design in areas not connected to the electric grid. Traditionally, such systems have been powered by diesel engine generator sets (DEGS), but also hybrid systems with photovoltaic and/or wind energy conversion systems (WECS) are becoming quite common nowadays. Hybrid energy systems can now be used to generate energy consumed in remote areas and stand-alone microgrids. This paper describes the design, simulation and feasibility study of a hybrid energy system for a stand-alone power system. A simulated model is developed to investigate the design and performance of stand-alone hydrogen renewable energy systems. The analysis presented here is based on transient system simulation program (TRNSYS) with realistic ventilation load of a large store. Design of a hybrid energy system is site specific and depends on the resources available and the load demand.

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

온라인 및 오프라인 PD 모니터링에 관한 연구 동향 (A Research Trend on On-Line/Off-Line PD Insulation Diagnostic System)

  • 추종훈;홍창일;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2008-2009
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is introduced.

  • PDF