• Title/Summary/Keyword: column-switching high-performance liquid chromatography

Search Result 24, Processing Time 0.022 seconds

Simple and Sensitive Determination of Baclofen in Human Plasma by Column-Switching and Semi-Micro High-Performance Liquid Chromatography

  • Ban, Eun-Mi;Ko, Hye-Ran;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.284.2-284.2
    • /
    • 2003
  • Using a column-switching technique. highly sensitive and selective semi-micro high-performance liquid chromatographic (HPLC) method has been developed for the determination of baclofen in human plasma. Following precipitation of plasma sample containing baclofen with zinc sulfate-acetonitrile, samples were directly injected on to the system. (omitted)

  • PDF

Column-switching High Performance Liquid Chromatographic Determination of Fluconazole in Human Plasma (컬럼 스위칭 고속액체크로마토그라프법을 이용한 혈장 중 플루코나졸의 분석)

  • Jee, Jun-Pil;Jin, Sook;Lee, Mi-Kyung;Kim, Yang-Bae;Kim, Chong-Kook
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.1
    • /
    • pp.51-54
    • /
    • 2000
  • A column-switching high performance liquid chromatographic method has been developed for the determination of a fluconazole in human plasma. Each plasma sample was centrifuged for 10 min at 5000 g. After an aliqout of the supernatant was taken to nylon microcentrifuge filter, these samples were centrifuged for 10 min at 5000 g. An aliqout of the supernatant was injected directly onto the HPLC column. Deionized water was run for 2 min at a flow rate of 1.0 ml/min to retain fluconazole in an extration column, while proteins and endogenous interferences were eluted to the waste. The analyte was then back-flushed onto an analytical column, $C_{18}$ reversed-phase column. The mobile phase for analytical column, 0.01 M sodium acetate (pH 5.0)-methanol (65:35, v/v), was run at a flow rate of 1.0 ml/min. The column effluent was monitored by ultraviolet detection at 261 nm. The retention time for fluconazole was 11.76 min in human plasma. The detection limit for fluconazole in human plasma was $0.2\;{\mu}g/ml$. No interference from endogenous substances was observed.

  • PDF

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

Coupled Column Chromatography in Chiral Separation of Salmeterol

  • Kim, Kyeong-Ho;Yun, Hyeong-Won;Kim, Hyun-Ju;Park, Hyun-Ji;Choi, Pok-Wha
    • Archives of Pharmacal Research
    • /
    • v.21 no.2
    • /
    • pp.212-216
    • /
    • 1998
  • A coupled achiral-chiral high-performance liquid chromatographic system has been developed for the determination of the enantiomers of salmeterol, S-(+)-salmeterol and R-(-)-salmeterol in urine. THe salmeterol was separated from the interfering components in urine and quantified on the silica column, and the enantiomeric composition was determined on a Sumichiral OA-4700 chiral stationary phase. The two columns were connected by a switching valve equipped with a silica precolumn. The two columns wer connected by a switching valve equipped with a silica precolumn. The precolumn was used to concentrate the salmeterol in the eluent from the achiral column before backflushing onto the chiral phase. The coupled system was validated.

  • PDF

Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry

  • Lee, Hyounyoung;Lim, Heungyoul;Yang, Juhong;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3629-3634
    • /
    • 2013
  • In this study, an improved method for the quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba leaf extract was developed. The samples were extracted with a mixture of chloroform and 50 % ethanol, after which the chloroform extract was dried and reconstituted in methanol. GAs with 13:0, 15:1, and 17:1 in the extract were successfully separated within 40 min and determined with high throughput performance using an online column-switching HPLC method using an SP column C8 SG80 ($4.6{\times}150mm$, $5{\mu}m$) and a Cadenza 5CD C18 column ($4.6{\times}150mm$, $3{\mu}m$). The developed HPLC method was validated for Ginkgo biloba leaf extract. The validation parameters were specificity, linearity, precision, accuracy, and limits of detection and quantitation (LODs and LOQs, respectively). It was found that all of the calibration curves showed good linearity ($r^2$ > 0.9993) within the tested ranges. The LODs and LOQs were all lower than $0.04{\mu}g/mL$. The established method was found to be simple, rapid, and high throughput for the quantitative analysis of GAs in ten commercial Ginkgo biloba leaf extract and dietary supplements. The samples were also analyzed in LC-electrospray ionization (ESI) tandem mass spectrometry (MS/MS) - multiple-ion reaction monitoring (MRM) mode to confirm the identification results that were obtained by the column switching HPLC-DAD method. The developed method is considered to be suitable for the routine quality control and safety assurance of Ginkgo biloba leaf extract.

Determination of Terbutaline Enantiomers in Human Plasma by Coupled Achiral-Chiral High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Kim, Hyun-Ju;Hong, Seon-Pyo;Shin, Sang-Deok
    • Archives of Pharmacal Research
    • /
    • v.23 no.5
    • /
    • pp.441-445
    • /
    • 2000
  • Achiral-chiral column switching HPLC assay was developed to allow the separation and quantification of the enantiomers of terbutaline in human plasma by means of fluorescence detection. Plasma samples were prepared by solid-phase extraction with sep-pak silica, followed by HPLC assay. The enantiomers of terbutaline and the internal standard were separated from the biological matrix on a silica column, and the two enantiomers were resolved and quantified on a Sumichiral OA-4900 column. The two columns were connected by a switching valve equipped with silica trap column, The trap column was used to concentrate the terbutaline in the eluent from the achiral column before back flushing onto the chiral phase. For each enantiomers, the assay was linear between 2.5-125 ng/$m\ell$ (r=0.9999) and detection limit was 1.0 ng/$m\ell$ .

  • PDF

DETERMINATION OF SIMVASTATIN IN HUMAN PLASMA BY COLUMN SWITCHING HPLC WITH UV DETECTION

  • Ban, Eun-Mi;Kim, Bae-Chan;Park, Tae-Hwan;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.281.1-281.1
    • /
    • 2003
  • Purpose. The purpose of this study was to develop and validate sensitive and specific analytical method for determinination of simvastatin in human plasma by the column-switching high-performance liquid chromatography (HPLC) system with UV detection. Methods. Simvastatin and internal standard were extracted into diethyl ether from plasma. (omitted)

  • PDF

Micro-Determination of D-Amino Acids in Milk by using Column Switching System (Column-Switching System을 이용한 우유속의 D-아미노산의 미량정량)

  • Lee, Sun Haing;Kim, Kyoung Hee;Lee, Young Cheol;Kim, Sang Tae
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.257-265
    • /
    • 1995
  • Free amino acids were isolated from milk and their absolute amounts were determined by reversed phase high performance liquid chromatography after derivatization with dansyl chloride. The determination of D- and L-amino acids was based on achiral separation on a C18 column. It was found that milk contained totally 41.00 mg DL-amino acids in 100 mL milk. The level of D-amino acids to L-amino acids was determined by a column-switching system combining an achiral reversed phase separation and chiral chelate additive. The chiral separation was carried out with addition of the chiral Cu(N-benzyl-L-proline)2 chelate to the mobile phase in reversed phase liquid chromatography. It was found that the determination of 16 different amino acids is feasible in the milk sample with a C18 column separation and 12 D-amino acids out of the 16 amino acids can be determined via the column-switching system with chiral separation. 2.05% of D-glutamic acid and 2.93% of D-alanine were found in milk.

  • PDF

High Performance Liquid Chromatographic Analysis of a New Proton Pump Inhibitor KR60436 and Its Active Metabolite O-Demethyl-KR60436 in Rat Plasma Samples Using Column-Switching

  • Lee, Hyun-Mee;Lee, Hee-Yong;Choi, Joong-Kwon;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.207-210
    • /
    • 2001
  • A fully automated high performance liquid chromatography with column-switching was developed for the simultaneous determination of KR60436, a new reversible proton pump inhibitor, and its active metabolite O-Demethyl-KR60436 from rat plasma samples. Plasma sample (50$\mu$l) was directly introduced onto a Capcell Pak MF Ph-1 column ($10{\times}4$ mm I.D.) where primary separation was occurred to remove proteins and concentrate target Substances Using acetonitrile-Potassium Phosphate (PH 7, 0.1 M) (2 : 8, v/v). The drug molecules eluted from MF Ph-1 column were focused in an intermediate column ($10{\times}2$ I.D.) by the valve switching step. The substances enriched in intermediate column were eluted and separated on a Vydac 218MR53 column ($250{\times}3.2$ I.D.) using acetonitrilepotassium phosphate (pH 7, 0.02 M) (47:53, v/v) at a flow rate of 0.5 ml/min when the valve status was switched back to A position. The method showed excellent sensitivity (detection limit of 2 ng/ml) with small volume of samples ($50{\mu}$l), good precision and accuracy, and speed (total analysis time 24 min) without any loss in chromatographic efficiency. The response was linear ($r^2{\geq}0.797$) over the concentration range of 5-500 ng/ml.

  • PDF