• 제목/요약/키워드: column-slab joint

검색결과 57건 처리시간 0.023초

PC 기둥-H형강보의 볼트접합부에관한 실험적 연구III (An Experimental Study III on the Bolted Connection between H-Beam and Precast-Concrete Column)

  • 여인석;박순규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.307-310
    • /
    • 2005
  • The PCS system, which consists of precast concrete column and steel beam, has been under development. Experimental test has been carried out to investigate the structural performance of the system under earthquake. Two types of test specimens of beam-column joints are designed in order to compare the performances. One is the system with reinforced concrete slab and the other is without slab. It is found that the system with slab could satisfy all of the requirements from ACI Criteria such as strength, stiffness degradation and energy dissipation capacity except initial stiffness. It is also investigated that the stiffness of the joint is belong to rigid joint type according to Bjorhovde criterion. And it is observed that the partial-composite system between beam and slab is more effective than full-composite system in the respect of the energy dissipation capacity of the system.

  • PDF

Behavior of composite CFST beam-steel column joints

  • Eom, Soon-Sub;Vu, Quang-Viet;Choi, Ji-Hun;Papazafeiropoulos, George;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • 제32권5호
    • /
    • pp.583-594
    • /
    • 2019
  • In recent years, composite concrete-filled steel tubular (CFST) members have been widely utilized in framed building structures like beams, columns, and beam-columns since they have significant advantages such as reducing construction time, improving the seismic performance, and possessing high ductility, strength, and energy absorbing capacity. This paper presents a new composite joint - the composite CFST beam-column joint in which the CFST member is used as the beam. The main components of the proposed composite joint are steel H-beams, CFST beams welded with the steel H-column, and a reinforced concrete slab. The steel H-beams and CFST beams are connected with the concrete slab using shear connectors to ensure composite action between them. The structural performance of the proposed composite joint was evaluated through an experimental investigation. A three-dimensional (3D) finite element (FE) model was developed to simulate this composite joint using the ABAQUS/Explicit software, and the accuracy of the FE model was verified with the relevant experimental results. In addition, a number of parametric studies were made to examine the effects of the steel box beam thickness, concrete compressive strength, steel yield strength, and reinforcement ratio in the concrete slab on the proposed joint performance.

Failure characteristics of columns intersected by slabs with different compressive strengths

  • Choi, Seung-Ho;Hwang, Jin-Ha;Han, Sun-Jin;Kang, Hyun;Lee, Jae-Yeon;Kim, Kang Su
    • Structural Engineering and Mechanics
    • /
    • 제74권3호
    • /
    • pp.435-443
    • /
    • 2020
  • The objective of this study was to determine the effective compressive strength of a column-slab connection with different compressive strengths between the column and slab concrete. A total of eight column specimens were fabricated, among which four specimens were restrained by slabs while the others did not have any slab, and the test results were compared with current design codes. According to ACI 318, the compressive strength of a column can be used as the effective compressive strength of the column-slab connection in design when the strength ratio of column concrete to slab concrete is less than 1.4. Even in this case, however, this study showed that the effective compressive strength decreased. The specimen with its slab-column connection zone reinforced by steel fibers showed an increased effective compressive strength compared to that of the specimen without the reinforcement, and the interior column specimens restrained with slabs reached the compressive strength of the column.

부분적인 비 부착 철근을 갖는 슬래브-기둥 접합부의 반복 횡하중 실험 (Tests of Slab-Column Connections with Partially Debonded Reinforcement under Cyclic Lateral Loading)

  • 최정욱;송진규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.13-16
    • /
    • 2006
  • This article summarizes tests conducted on two full-scale interior slab-column connections with and without partially debonded reinforcement subjected to cyclic loading. Each test specimen consisted of a 4.2m square slab with a 355mm square column protruding 1.5m above and below the slab. The slab thickness was 152mm. The specimen with partially debonded reinforcement exhibited more lateral drift capacity than did the specimen with fully bonded reinforcement. With partial debonding of the flexural reinforcement, cyclic load appeared to produce less damage to the connection in the vicinity of the slab-column joint region.

  • PDF

횡력을 받는 넓은 보-기둥 내부 접합부의 거동 평가 (Behavior of Wide Beam-Column Interior Joint with Slab)

  • 이범식;박성식;박지영
    • 토지주택연구
    • /
    • 제3권4호
    • /
    • pp.433-449
    • /
    • 2012
  • 횡력을 받는 넓은 보와 기둥 내부접합부의 거동을 평가하기 위하여 넓은 보-기둥 접합부의 휨강성비와 유효폭 및 슬래브 유무를 변수로 6개의 1/2축소 모델 실험체를 제작하여 구조성능 평가를 수행하여 하중-변형, 연성, 강성 등을 평가하였다. 동 모델을 대상으로 비탄성해석을 수행하여 구조성능평가 결과와 비교하였다. 연구결과 도출된 결론은 다음과 같다. 넓은 보-기둥 내부 접합부는 중진지역인 국내에서 적용하고 있는 부분골조형 구조에 적용이 가능한 것으로 판단된다. 슬래브의 강성이 횡력을 받는 넓은 보-기둥 내부 접합부의 거동에 영향을 미치는 것으로 나타났다. 휨강성비가 2.0이상의 경우 T형보의 플랜지로서 슬래브 유효폭은 넓은 보 유효깊이의 2.0d로 평가되며, 휨강성비가 1.4~2.0일 경우, 슬래브 유효폭의 영향은 고려하지 않아도 되는 것으로 나타났다.

Nonlinear Finite Element Analysis on the Transmission of Column Loads through Slab-Column Connections

  • 윤영수;이주하;손유신;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.466-469
    • /
    • 2006
  • This paper presents the structural characteristics of slab-column connections by using nonlinear finite element analysis. FEA considering material non-linearity was performed to investigate average column strain, failure mode, principal stress distribution, and steel yielding conditions for various slab-column members. In addition, to investigate alternative methods for improving the strength of interior column-slab joints, some specimens were provided with different reinforcing types of high-strength concrete puddling, high-strength column longitudinal steels, dowel bars, and high-strength concrete core. To make certain of the reliability of the analytical program, analysis results for concrete material model developed and two specimens with and without puddling were compared with experimental results. It was found that providing the alternative reinforcing methods in the slab-column joint results in a significant improvement in performance. This includes an increase in the axial compressive strength, greater loading stiffness, and ductility.

  • PDF

슬래브가 있는 고강도 철근 콘크리트 넓은 보-기둥 접합부의 거동 (Behavior of High Strength Reinforced Concrete Wide Beam-Column Joint with Slab)

  • 최종인;안종문;신성우;박성식;이범식;양지수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.493-498
    • /
    • 2002
  • An experimental investigation was conducted to study the behavior of high-strength RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were compressive strength of concrete( $f_{ck}$ =240, 500kgf/c $m^2$), the ratio of the column-to-beam flexural capacity( $M_{r}$=2$\Sigma$ $M_{c}$$\Sigma$ $M_{b}$ ; 0.77-2.26), extended length of the column concrete($\ell$$_{d}$ ; 0, 9.6, 30cm), ratio of the column-to-beam width(b/H ; 1.54, 1.67). Test results are shown that (1) the behavior of specimen using high-strength concrete satisfied the required minimum ductile capacity according to increase the compressive strength, (2). In the design of the wide beam-column joints, one should be consider the effects of slab stiffness which is ignored in the current design code and practice.ice.e.e.

  • PDF

고강도 RC 보-기둥 접합부의 비탄성 거동에 대한 슬래브의 영향 (Slab Effect on Inelastic Behaviors of High Strength RC Beam-Column Joints)

  • 장극관;김윤일;오영훈
    • 콘크리트학회지
    • /
    • 제9권2호
    • /
    • pp.167-177
    • /
    • 1997
  • 모멘트 연성골조의 접합부와 기둥은 적절한 에너지흡수 능력과 구조물의 횡붕괴를 방지하기 위하여 탄성적으로 거동해야 하며, "강한 기둥-약한 보"의 설계개념을 채택하고 있다. 접합부는 골조구조의 취약부분으로 인정되고 있지만 부재설계에서는 접합부를 구성하는 보와 기둥에 의해서 접합부의 치수가 결정되기 때문에 접합부가 부담해야 하는 하중조건과 보강방법을 결정하는데에 어려움이 있다. 또한 콘크리트의 고강도화, 경량화에 의해 부재단면은 작아지게 되고 상대적으로 철근량은 늘어나게 되므로 접합부 영역의 응력부담은 이전보다 훨씬 높아지게 되었다. 따라서 접합부의 적절한 구조성능 확보 및 시공상의 문제점을 개선하기 위하여 접합부의 설계 및 상세에 특별한 주의가 필요하다고 할 수 있다. 이에 본 연구에서는 슬래브의 기여도를 고려한 접합부의 적절한 보강방법을 제시하기 위한 기초자료로서 $\frac{2}{3}$의 실물크기로 4개의 고강도 콘크리트 보-기둥 접합부를 제작하고, 반복하중 실험을 수행하였다.실험을 수행하였다.

SFRHPC interior beam-column-slab joints under reverse cyclic loading

  • Ganesan, N.;Nidhi, M.;Indira, P.V.
    • Advances in concrete construction
    • /
    • 제3권3호
    • /
    • pp.237-250
    • /
    • 2015
  • Beam-column joints are highly vulnerable locations which are to be designed for high ductility in order to take care of unexpected lateral forces such as wind and earthquake. Previous investigations reveal that the addition of steel fibres to concrete improves its ductility significantly. Also, due to presence of slab the strength and ductility of the beam increases considerably and ignoring the effect of slab can lead to underestimation of beam capacity and defiance of strong column weak beam concept. The influence of addition of steel fibres on the strength and behaviour of steel fibre reinforced high performance concrete (SFRHPC) interior beam-column-slab joints was investigated experimentally. The specimens were subjected to reverse cyclic loading. The variable considered was the volume fraction of crimped steel fibres i.e., 0%, 0.5% and 1.0%. The results show that the addition of steel fibres improves the first crack load, strength, ductility, energy absorption capacity and initial stiffness of the beam.

Prediction of the Effective Concrete Strength for Column-Slab Connections

  • Lee, Joo-Ha;Lee, Seung-Hoon;Sohn, Yu-Shin;Yoon, Young-Soo
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.577-578
    • /
    • 2009
  • For cases where the column concrete strength exceeds 1.4 times the slab concrete strength, the KCI Code requires that either: puddled high-strength concrete(HSC) be used in the slab, or the use of vertical dowels and spirals through the joint, or the use of an effective concrete strength in the joint. This paper studies on the third strategy. A prediction model of the effective concrete strength for interior columns was proposed using an analogy of brick and mortar in brick masonry. The proposed prediction model is verified by comparison with experimental results and various design equations.

  • PDF