• 제목/요약/키워드: column shear force

검색결과 213건 처리시간 0.027초

Seismic behavior of steel reinforced concrete cross-shaped column under combined torsion

  • Chen, Zongping;Liu, Xiang
    • Steel and Composite Structures
    • /
    • 제26권4호
    • /
    • pp.407-420
    • /
    • 2018
  • Experiments were performed to explore the hysteretic performance of steel reinforced concrete (SRC) cross-shaped columns. Nine specimens were designed and tested under the combined action of compression, flexure, shear and torsion. Torsion-bending ratio (i.e., 0, 0.14, 0.21) and steel forms (i.e., Solid - web steel, T - shaped steel, Channel steel) were considered in the test. Both failure processes and modes were obtained during the whole loading procedure. Based on experimental data, seismic indexes, such as bearing capacity, ductility and energy dissipation were investigated in detail. Experimental results suggest that depending on the torsion-bending ratio, failure modes of SRC cross-shaped columns are bending failure, flexure-torsion failure and torsion-shear failure. Shear - displacement hysteretic loops are fuller than torque - twist angle hysteretic curves. SRC cross-shaped columns exhibit good ductility and deformation capacity. In the range of test parameters, the existence of torque does not reduce the shear force but it reduces the displacement and bending energy dissipation capacity. What is more, the bending energy dissipation capacity increases with the rising of displacement level, while the torsion energy dissipation capacity decreases.

전단이 RC 교각의 지진성능 및 파괴모드에 미치는 영향 (Influence of shear on seismic performance and failure mode of RC piers)

  • 이도형
    • 공학논문집
    • /
    • 제6권1호
    • /
    • pp.53-63
    • /
    • 2004
  • 본 연구에서는 지진하중을 받는 철근콘크리트 교각의 지진성능 및 파괴모드에 전단이 미치는 영향을 조사하였다. 본 연구에서 개발된 전단-축력간의 상호거동 이력응답 모델의 검증을 위하여 철근콘크리트 기둥 실험에 대한 비교해석을 수행하였다. 비교결과, 예측된 해석치는 전단에 관한 하중-변위 이력응답에 있어서 실험결과와 좋은 상관관계를 보여주었다. 아울러, 본 연구에서 개발된 모델을 이용하여 고베 지진에 의해서 손상된 철근콘크리트 교량의 비선형 시간이력 해석을 수행하였다. 교각의 변위응답에 관한 분석결과, 축력의 변화를 고려한 전단의 영향으로 인하여 최대변위가 상당히 증가하였고, 전반적인 교각 강성의 감소와 함께 진동주기의 증가를 유발한다는 것을 알 수 있었다. 따라서 전단과 축력의 영향을 동시에 고려한 응답에 철근콘크리트 교각의 지진손상 평가에 관해서 보다 나은 설명을 제공할 수 있을 것으로 사료된다.

  • PDF

Determination of critical excitation in seismic analysis of structures

  • Kamgar, Reza;Rahgozar, Reza
    • Earthquakes and Structures
    • /
    • 제9권4호
    • /
    • pp.875-891
    • /
    • 2015
  • Earthquake can occur anywhere in the world and it is essential to design important members in special structures based on maximum possible forces that can be produced in them under severe earthquake. In addition, since the earthquake is an accidental phenomena and there are no similar earthquakes, therefore the possibility of strong earthquakes should be taken into account in earthquake-resistant design of important structures. Based on this viewpoint, finding the critical acceleration which maximizes internal forces is an essential factor in structural design. This paper proposes critical excitation method to compute the critical acceleration in design of important members in special structures. These critical accelerations are computed so that the columns' internal shear force at the base of the structure at each time step is maximized under constraints on ground motion. Among computed critical accelerations (of each time step), the one which produces maximum internal shear force is selected. A numerical example presents to show the efficiency of critical excitation method in determining the maximum internal shear force and base moment under variety of constraints. The results show that these method can be used to compute the resonant earthquake which have large enough effective duration of earthquake strong motion (between 12.86 sec to 13.38 sec) and produce the internal shear force and base moment for specific column greater than the same value for selected earthquakes in constructing the critical excitation (for different cases about 2.78 to 1.29 times the San Fernando earthquake). Therefore, a group of them can be utilized in developing the response spectrum for design of special structures.

Study on failure mechanism of multi-storeyed reinforced concrete framed structures

  • Ahmed, Irfan;Sheikh, Tariq Ahmad;Gajalakshmi, P.;Revathy, J.
    • Advances in Computational Design
    • /
    • 제6권1호
    • /
    • pp.1-13
    • /
    • 2021
  • Failure of a Multi-storeyed reinforced concrete framed structure occurs when a primary vertical structural component is isolated or made fragile, due to artificial or natural hazards. Load carried by vertical component (column) is transferred to neighbouring columns in the structure, if the neighbouring column is incompetent of holding the extra load, this leads to the progressive failure of neighbouring members and finally to the failure of partial or whole structure. The collapsing system frequently seeks alternative load path in order to stay alive. One of the imperative features of collapse is that the final damage is not relative to the initial damage. In this paper, the effect on the column and beam adjacent to statically removed vertical element in terms of axial force, shear force and bending moment is investigated. Using Alternate load path method, numerical modelling of two dimensional one bay, two bay with variation in storey heights are analysed with FE model in order to obtain better understanding of failure mechanism of multi-storeyed reinforced concrete framed structure. The results indicate that the corner column is more susceptible to progressive collapse when compared to middle column, using this simplified methodology one can easily predict how the structure can be made to stay alive in case of sudden failure of any horizontal or vertical structural element before designing.

납면진장치의 위치변화에 따른 면진교량의 동특성 (Dynamci Behaviors of Seismically Isolated Bridges According to Different Location of Lead Rubber Bearings)

  • 박정근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.383-390
    • /
    • 2000
  • The purpose of this paper is to investigate dynamic characteristics of an isolated bridge with a different location of seismic isolation at piers and to determine the best location of seismic isolation. The substructure of the bridge is two column framed type reinforced concrete and has relatively high piers so it has long natural period, To decide the best location of seismic isolations displacement shear force bending moment acceleration and absorbed energy are compared using fast nonlinear analysis. To isolate overall structures is effective to bending moments and shear forces for long period bridges.

  • PDF

강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석 (Parameter Study of Buckling Behavior of Steel Built-up Column)

  • 김진용;김성보
    • 대한토목학회논문집
    • /
    • 제31권2A호
    • /
    • pp.79-87
    • /
    • 2011
  • 이 연구에서는 압축력을 받는 강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석을 수행하였다. 압축력을 받는 조립기둥에서 기둥 전체 길이에 설치되는 H-형강 단면의 주 부재와 H-형강의 상 하 플랜지를 연결하는 배튼의 휨 및 전단력에 의한 전단변형효과를 고려한 좌굴하중 식을 제시하였다. 조립기둥의 길이, H-형강 주부재의 간격, 배튼의 개수, 배튼 작용을 하는 상 하 덮개판의 설치 여부에 따른 좌굴하중의 변화를 분석하였다. 일반 볼트 및 고장력 볼트가 사용된 조립 기둥의 설계에 사용되는 AISC 설계식이 배튼 및 주 부재의 간격이 큰 조립 기둥에도 활용할 수 있는지에 대한 적용성을 검토하였다. 이 연구에서 제시한 엄밀해 그리고 보요소 및 판요소를 사용한 유한요소해석 그리고 AISC의 설계식에 의한 결과를 비교 분석하여 강재 조립기둥의 좌굴거동에 대한 매개변수 해석을 수행하였다.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;손국원
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 시간이력해석 (Inelastic Time History Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection)

  • 강석봉;김신애
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.313-324
    • /
    • 2010
  • 본 연구에서는 반강접 접합부 배치에 따른 구조물 거동특성을 파악하기 위하여 KBC2005 건축구조설계기준으로 비가새 5층 철골 구조물을 설계하여 모든 접합부를 완전 강접합부와 반강접 접합부로 이상화한 경우 그리고 반강접 접합부를 수직배치 및 수평배치한 경우에 대하여 비탄성 시간이력 구조해석을 실시하였다. 철골 보 및 기둥의 모멘트-곡률 관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델 그리고 철골 보, 기둥 및 접합부의 이력거동은 3-매개변수 모델을 이용하여 나타내었다. 4개 지진파에 대한 재현주기 2400년 위험수준에 해당하는 최대지반가속도와 5% 층간변위에 대한 푸쉬오버 구조해석의 최대밑면전단력 발생 최대지반가속도에 대하여 시간이력 구조해석을 실시하여 밑면전단력, 지붕층 변위, 층간변위, 접합부 요구연성도, 기둥, 보 및 접합부의 최대휨모멘트 그리고 소성힌지 분포 등을 확인하였다. 반강접 접합부를 수직적으로 외부에 배치할수록 최대밑면전단력과 층간변위는 감소하며, 수평적으로 상부층에 배치할수록 접합부 요구연성도가 감소하였다. 푸쉬오버 구조해석과 시간이력 구조해석에서 최대층간변위 발생 위치가 다르고 크기는 푸쉬오버 구조해석에서 과대평가되었다. 밑면전단력, 층간변위 및 접합부 요구연성도를 위한 가장 바람직한 반강접 접합부 배치는 수직적으로 외부에 배치하는 것이다.

전단경간비가 작은 철근콘크리트 기둥의 소성힌지 길이 (Plastic Hinge Length of Reinforced Concrete Columns with Low Height-to-Width Ratio)

  • 박종욱;우재현;김병일;이정윤
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.675-684
    • /
    • 2010
  • 철근콘크리트 부재는 연성파괴를 유도하기 위해서 휨인장 파괴가 선행 하도록 구조설계한다. 또한 보에서 파괴가 진행하도록 하여 기둥에는 피해가 적게 발생하도록 한다. 하지만 소성붕괴메카니즘에 의하여 소성힌지는 보의 양단부에 발생한 이후 최종적으로 최하층 기둥의 하부에도 발생한다. 철근콘크리트 구조물의 최하층 기둥은 축력이 크게 작용하고 전단경간이 비교적 작기 때문에 휨항복을 했다고 하더라도 최종적으로는 전단파괴하거나 부차파괴하여 설계보다 취성적으로 파괴 할 가능성이 있다. 이 논문에서는 휨항복 후 전단파괴하는 10개의 실험체를 통해 소성힌지 영역의 변형율과 길이 확장에 주는 요소에 대해 파악하였다. 실험결과 세 변수 중에서 축력이 가장 크게 영향을 미쳤는데 축력이 클수록 축방향 변형률과 연성비가 뚜렷하게 줄어드는 현상을 확인할 수 있었으며 소성힌지 길이는 약간 늘어났다. 실험을 통해서 산출한 소성힌지 길이는 약 0.7~1.4d였으며 이는 기존 연구자들이 제안했던 평가식과 차이를 보여주었다.

TSD 접합부의 강성을 고려한 5층 철골골조구조물의 비탄성 시간이력해석 (Inelastic Time History Analysis of a Five-Story Steel Framed Structure Considering Rigidity of TSD Connection)

  • 강석봉;이재환
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.281-291
    • /
    • 2010
  • 본 연구에서는 횡력을 받는 구조물 거동에 대한 보-기둥 접합부의 영향을 확인하기 위하여 5층 철골구조물을 KBC2005 건축구조 설계기준에 맞게 구조설계 하였으며 접합부를 완전 강접합부로 이상화한 경우와 반강접 접합부로 설계하였다. 철골 보 및 기둥의 모멘트-곡률관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 파워모델 그리고 철골 보, 기둥 및 접합부의 이력거동은 3-매개변수 모델을 이용하여 나타내었다. 5층 철골구조물은 개별골조와 연결골조의 2차원 구조물로 이상화하였다. 4개 지진파의 재현주기 수준별로 산정한 최대지반가속도와 푸쉬오버해석의 최대밑면전단력을 위한 지반가속도에 대하여 시간이력해석을 실시하여 지붕층 변위, 밑면전단력, 층간변위, 접합부 요구연성도, 기둥, 보 및 접합부의 최대모멘트 그리고 소성힌지 분포 등을 확인하였다. 반강접 접합부 골조는 완전 강접합 골조에 비해 적은 밑면전단력이 발생하였으며 기둥, 보 및 접합부에 발생하는 휨모멘트의 크기와 증가율도 적었다. TSD 접합부는 우리나라 설계수준의 지진하중에 대하여 예제 구조물에서 경제성과 안전성을 확보 할 수 있음을 확인할 수 있었다.