• 제목/요약/키워드: column effect

검색결과 2,092건 처리시간 0.024초

SFRHPC interior beam-column-slab joints under reverse cyclic loading

  • Ganesan, N.;Nidhi, M.;Indira, P.V.
    • Advances in concrete construction
    • /
    • 제3권3호
    • /
    • pp.237-250
    • /
    • 2015
  • Beam-column joints are highly vulnerable locations which are to be designed for high ductility in order to take care of unexpected lateral forces such as wind and earthquake. Previous investigations reveal that the addition of steel fibres to concrete improves its ductility significantly. Also, due to presence of slab the strength and ductility of the beam increases considerably and ignoring the effect of slab can lead to underestimation of beam capacity and defiance of strong column weak beam concept. The influence of addition of steel fibres on the strength and behaviour of steel fibre reinforced high performance concrete (SFRHPC) interior beam-column-slab joints was investigated experimentally. The specimens were subjected to reverse cyclic loading. The variable considered was the volume fraction of crimped steel fibres i.e., 0%, 0.5% and 1.0%. The results show that the addition of steel fibres improves the first crack load, strength, ductility, energy absorption capacity and initial stiffness of the beam.

Behaviour of large fabricated stainless steel beam-to-tubular column joints with extended endplates

  • Wang, Jia;Uy, Brian;Li, Dongxu
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.141-156
    • /
    • 2019
  • This paper presents the flexural behaviour of stainless steel beam-to-tubular column joints with extended endplates subjected to static loading. Moment-rotation relationships were investigated numerically by using Abaqus software with geometric and material nonlinearity considered. The prediction of damages among components was achieved through ductile damage models, and the influence of initial geometric imperfections and residual stresses was evaluated in large fabricated stainless steel joints involving hollow columns and concrete-filled columns. Parametric analysis was subsequently conducted to assess critical factors that could affect the flexural performance significantly in terms of the initial stiffness and moment resistance. A comparison between codes of practice and numerical results was thereafter made, and design recommendations were proposed for further applications. Results suggest that the finite element model can predict the structural behaviour reasonably well with the component damage consistent with test outcomes. Initial geometric imperfections and residual stresses are shown to have little effect on the moment-rotation responses. A series of parameters that can influence the joint behaviour remarkably include the strain-hardening exponents, stainless steel strength, diameter of bolts, thickness of endplates, position of bolts, section of beams and columns. AS/NZS 2327 is more reliable to predict the joint performance regarding the initial stiffness and moment capacity compared to EN 1993-1-8.

Study on failure mechanism of multi-storeyed reinforced concrete framed structures

  • Ahmed, Irfan;Sheikh, Tariq Ahmad;Gajalakshmi, P.;Revathy, J.
    • Advances in Computational Design
    • /
    • 제6권1호
    • /
    • pp.1-13
    • /
    • 2021
  • Failure of a Multi-storeyed reinforced concrete framed structure occurs when a primary vertical structural component is isolated or made fragile, due to artificial or natural hazards. Load carried by vertical component (column) is transferred to neighbouring columns in the structure, if the neighbouring column is incompetent of holding the extra load, this leads to the progressive failure of neighbouring members and finally to the failure of partial or whole structure. The collapsing system frequently seeks alternative load path in order to stay alive. One of the imperative features of collapse is that the final damage is not relative to the initial damage. In this paper, the effect on the column and beam adjacent to statically removed vertical element in terms of axial force, shear force and bending moment is investigated. Using Alternate load path method, numerical modelling of two dimensional one bay, two bay with variation in storey heights are analysed with FE model in order to obtain better understanding of failure mechanism of multi-storeyed reinforced concrete framed structure. The results indicate that the corner column is more susceptible to progressive collapse when compared to middle column, using this simplified methodology one can easily predict how the structure can be made to stay alive in case of sudden failure of any horizontal or vertical structural element before designing.

D/B기반 외부폭발에 의해 기둥에 작용하는 폭압이력 예측 모델 (Prediction Model of Blast Load Acting on a Column Component Under an External Explosion Based on Database)

  • 성승훈;차정민
    • 한국전산구조공학회논문집
    • /
    • 제35권4호
    • /
    • pp.207-214
    • /
    • 2022
  • 본 연구에서는 유한요소해석 D/B를 기반으로 보간식을 산출하여 개활지 폭발현상에 의해 기둥에 작용하는 폭압이력을 예측하는 모델을 개발했다. D/B 구성을 위해 7종류 기둥 너비에 대해 총 70회의 유한요소해석을 수행했다. 제안하는 방법의 성능확인을 위해, 기존에 제시된 경험식 기반의 예측식과의 비교연구를 수행했다. 또한, D/B를 구성하는 point 외의 영역에서의 예측 정확도 확인을 위해 유한요소해석 결과와의 비교/검증 연구를 추가로 수행했다. 제안하는 방법은 기존의 경험식 기반 예측식에 비해 유한요소해석 결과와 유사한 결과를 산출함을 확인했다.

Comparison of support vector machines enabled WAVELET algorithm, ANN and GP in construction of steel pallet rack beam to column connections: Experimental and numerical investigation

  • Hossein Hasanvand;Tohid Pourrostam;Javad Majrouhi Sardroud;Mohammad Hasan Ramasht
    • Structural Engineering and Mechanics
    • /
    • 제87권1호
    • /
    • pp.19-28
    • /
    • 2023
  • This paper describes the experimental investigation of steel pallet rack beam-to-column connec-tions. Total behavior of moment-rotation (M-φ) curve and the effect of particular characteristics on the behavior of connection were studied and the associated load strain relationship and corre-sponding failure modes are presented. In this respect, an estimation of SPRBCCs moment and rotation are highly recommended in early stages of design and construction. In this study, a new approach based on Support Vector Machines (SVMs) coupled with discrete wavelet transform (DWT) is designed and adapted to estimate SPRBCCs moment and rotation according to four input parameters (column thickness, depth of connector and load, beam depth,). Results of SVM-WAVELET model was compared with genetic programming (GP) and artificial neural networks (ANNs) models. Following the results, SVM-WAVELET algorithm is helpful in order to enhance the accuracy compared to GP and ANN. It was conclusively observed that application of SVM-WAVELET is especially promising as an alternative approach to estimate the SPRBCCs moment and rotation.

Shear strength response of clay and sand column with different sand grain shapes

  • Zuheir Karabash;Ali Firat Cabalar
    • Geomechanics and Engineering
    • /
    • 제35권2호
    • /
    • pp.135-147
    • /
    • 2023
  • Sand columns in clayey soil are considered one of the most economical and environmentally-friendly soil-improving techniques. It improves the shear strength parameters, reduces the settlement, and increases the bearing capacity of clayey soils. The aim of this paper is to study the effect of grain shape in sand columns on their performance in improving the mechanical properties of clayey soils. An intensive series of consolidated-drained triaxial tests were performed on clay specimens only and clay specimens with sand columns. The parameters examined during the experimental work were grain shape in sand columns (angular, rounded, sub-rounded) and effective confining pressure (50 kPa, 100 kPa, 200 kPa). The results indicated that there is a significant improvement in the deviatoric stress and stiffness values of specimens with sand columns. Improving deviatoric stress values in the use of angular sand grains was found to be higher than those in the use of sub-rounded and rounded sand grains. A 187%, 159%, and 153% increment in deviatoric stress values were observed for the sand columns with angular, sub-rounded, and rounded grain shapes, respectively. The specimens were observed to be more contractive as the sand column was installed, and as the angularity of grains in the sand column was increased. Sand column installation improves significantly the angle of internal friction, and the effective angle of internal friction increases as the angularity of the sand grains increases.

잎담배 성분중 갈색고분자 물질의 분리정제 및 열분해에 관한 연구 (The Isolation and Pyrolysis of the Brown Pigmented Macromolecule from the Cured Leaf Tobacco)

  • 채쾌;박지창
    • 한국연초학회지
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 1980
  • 건조잎담배로부터 단백질로 간주되는 고분자 물질의 gel filtration column chromatography(Sephadex G-75), 투석 그리고 흡착 chromatography의 일종인 brushite column chromatography분리를 시도한 결과, 짙은 갈색의 고분자 물질을 얻었다. Sephadex column에 의한 분리 profile를 보면 분자량이 상이한 두종류의 갈색고분자 물질이 존재함을 확인하였고 brushite column의 분리 profile에 의하면 분자의 전자구조가 다른 두 종류의 고분자가 있음이 나타났다. Burley와 Hicks의 경우 단백질 분해효소에 의한 분해효과를 측정해본 결과, 가장 큰 분해효과를 보인 효소는 chymotrypsin으로 Burley에서 16-30%수준까지 분해현상을 나타내 주었으며 Hicks인 경우 38-57%까지 감소현상을 보여 주었다. Pepsin처리효과는 chymotrypsin처리구와 비슷한 수준을 보였으나 trypsin경우는 매우 낮은 분해현상을 나타냈다. 단백질 분해효소로 처리된 시료의 sephadex column분리 profile을 살펴보면, 분자량이 보다 큰 fraction의 경우 peak가 거의 완전하게 사라짐을 관찰할 수 있으나, 작은 분자량Peak는 약간의 감소현상만을 보여 주었다. 투석후의 갈색 고분자물질을 $300^{\circ}C$에서 연소시킨 경우, 연소전에 관찰할 수 없었던 강한 형광성 물질이 생성되었는데 TLC에 의한 분리후, 이 형광성 물질끈 흡수 스펙트라를 측정해 본 결과, 최대흡수 파장이 265. 275nm(benzene용매)로 나타났으며 스펙트럼 끈 모양이 polynuclear aromatic hydrocarbon(PAH) 계열 화합물의 것과 유사함을 보여 주었다.

  • PDF

Behavior of Steel Fiber Reinforced Concrete Columns under Cyclic Loading

  • 장극관;이현호
    • 콘크리트학회논문집
    • /
    • 제16권3호
    • /
    • pp.415-423
    • /
    • 2004
  • To improve the brittle column behavior during seismic excitation, benefits of using steel fiber reinforced concrete in columns were investigated. For experimental study, eight specimens were used to evaluate the shear enhancement effect. The variables in this study were amount of shear reinforcement ratio (i.e., 0.26, 0.21 $\%$) and steel fiber volume fraction (i.e., 0.0, 1.0, 1.5, 2.0$\%$). The test results indicated that the maximum enhancement of shear capacity was shown in $1.5\%$ steel fiber content. In addition, to predict the maximum shear strength, equations of ACI 318-99, AIJ MB, NZS 3101, Hirosawa and Priestley were reviewed. From the parametric and regression study, modified Priestely equation was proposed by adding steel fiber effect.

CFS 보강 콘크리트 기둥의 보강효과 산정을 위한 해석적 연구 (Numerical Study for the Estimation of Strengthening Effect of Concrete Column Strengthened with CFS)

  • 이상호;허원석;박재우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.709-714
    • /
    • 1999
  • The objectives of this study are to estimate the strengthening effect of concrete column strengthened with CFS and to provide basic guideline for the strengthening design with laminated composite materials. Analysis stress-strain model of laminated CFS is presented based on laminate theory. This model has been implemented in the algorithm of evaluating confinement effect of CFS. From results of the algorithm, stress-strain relationship of confined concrete is obtained. Using this stress-strain relationship, section analyses of circular and rectangular concrete columns strengthened with CFS are carried our, and load-moment interaction and load-ductility curves of the columns are obtained. To evaluate the strengthening effects of CFS, parametric study is also conducted for the angle of ply, thickness of CFS, shape of section, and reinforcement ratio. Based on this investigation, design recommendations and basic guidelines for the strengthening design with CFS are proposed.

  • PDF

콘크리트 강도 및 강관 폭두께비에 따른 각형 CFT 단주의 내력평가 (Strength Evaluation of Rectangular CFT Stub Columns varing with Concrete Strength and Width-to-Thickness Ratio of Steel Tubes)

  • 심종석;한덕전
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권2호
    • /
    • pp.31-39
    • /
    • 2011
  • Concrete-filled steel tube(CFT) columns have become popular for building construction due to not only composite effect of steel tube and infilled concrete, but also more economical. The purpose of this paper is to propose the applicable boundary formula of width-to-thickness ratio for rectangular steel tube as using CFT column. A parametric study was performed taking width-to-thickness ratio of rectangular steel tube and compressive strength of concrete as the main parameter. The strength of concrete are selected to 30, 60, 90MPa. The non-linear analysis was adopted in order to take into account the effect of concrete strength. Finally, from the test and analysis results, the effect of increasing strength according to concrete strength and width-to-thickness of steel tube and plastic behavior of specimens were verified distinctly.