• 제목/요약/키워드: colorimetric spectrometer

검색결과 8건 처리시간 0.025초

Determination of Cholesterol by a Diode Laser/Fiber Optic Colorimetric Spectrometer

  • 김성호;남성만;변상길;윤신영;홍성식
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권4호
    • /
    • pp.389-392
    • /
    • 2000
  • A simple and inexpensive colorimetric spectrometer for determining total cholesterol has been developed,comprising a diode laser as the light sourcoptical fibers for the light guide and a photodiode as the detector.The stabilty and performance of the new system was investigated by obtaining the calibration curve for stan-dard cholesterol solutions. The total cholesterol in humanserum was also measured by the analyzer and com-pared with the value obtained by a conventional spectrometer. The results showed that the developed spectrometer was useful for the determination of cholesterol levels. The visible diodelaser used in the study exhibited good spectroscopic and operational properties for colorimetric absorption spectrometry and could be a key component for the development of a simple and economical analyzer.

Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors

  • Heo, Eun-Yeong;Ko, Young-Il;Bae, Jin-Seok
    • 한국염색가공학회지
    • /
    • 제21권5호
    • /
    • pp.51-57
    • /
    • 2009
  • Since heavy metal pollution is a significant global environmental problem and very dangerous to human health, the improved methods for detecting heavy metals are required recently. Colorimetric chemosensors are now considered as one of the most effective analytical method used in the environment monitoring. New direct dyes having the function of colorimetric chemosensors were synthesized. When metal ions such as $Al^{3+}$, $Ca^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Cu^{2+}$, $Fe^{2+}$, $Fe^{3+}$, $Hg^{2+}$, $Li^+$, $Mg^{2+}$, $Na^+$, $Ni^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ were added each solution of new direct dyes, the color of solution was changed and can be easily detected with naked eyes without expensive experimental equipment such as atomic absorption spectrometer (AAS) or inductively coupled plasma?mass spectrometer (ICP-MS). The new benzidine analogues were diazotized and reacted with couplers such as H-acid, J-acid, Chromotropic acid, Nevill-winther acid and gamma acid to synthesize new direct dyes. The structures of the new direct dyes were confirmed by high resolution mass spectrometer (FAB ionization) and evaluated with UV-Vis spectroscopy. The UV-VIS spectroscopy was measured for the dye solutions by adding various concentrations of metal ions. It was observed that the absorbance in UV-Vis spectra was changed as the heavy metal ions were added.

다이오드 레이저 비색 분광기를 이용한 Cetylpyridinium Chloride의 농도분석 (Application of a Diode Laser Colorimetric Spectrometer to Determination of Cetylpyridinium Chloride)

  • Park, Keun-Woo;Kim, Se-Yun;Shin, Chul-Min;Seo, Jeong-Woon;Hyun, Hye-Jin;Nam, Hae-Seon;Kim, Sung-Ho
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.307-310
    • /
    • 2003
  • In order to analyze the concentration of cetylpyridinium chloride(CPC), a widely used cationic surfactant, we developed a simple and compact spectrometer, which consisted of a diode laser and a photodiode detector. Preliminary results are described here on the performances of the system in terms if the stability of output intensity, sensitivity, and reproducibility. Data on the comparisons of the system with the conventional UV-VIS spectrometer are also given. With the instrument, the concentration of CPC between 3${\times}$10$\^$-5/M and 1.1${\times}$ 10$\^$-4/M are calibrated as a correlation coefficient of 0.9635. The results shown here indicate a potential for developing a portable spectrometer useful for analyzing concentrations of CPC.

  • PDF

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

Plant Analysis Methods for Evaluating Mineral Nutrient

  • Lee, Ye-Jin;Sung, Jwa-Kyung;Lee, Seul-Bi;Lim, Jung-Eun;Song, Yo-Sung;Lee, Deog-Bae;Hong, Suk-Young
    • 한국토양비료학회지
    • /
    • 제50권2호
    • /
    • pp.93-99
    • /
    • 2017
  • Analysis of mineral nutrients in plant is required for evaluating diagnosis of plant nutritional status. Pretreatment procedure for the analysis of plant can be varied depending on elements to be analyzed. Wet-digestion is suitable for total nitrogen, phosphate and cations, however, digestion solution including nitric acid is not suitable for nitrogen analysis. Incineration procedure is required to analyze chloride, silicate and total sulfur. After digestion, total nitrogen is analyzed by Kjeldahl method, and phosphate is detected at 470nm by colorimetric analysis with ammonium meta vanadate. Cations and micro elements are determined by titration or colorimetry, also, these elements can be measured by Atomic absorption spectrometer (AAS) or Inductively coupled plasma spectrometer (ICP).

입자크기와 중합온도 제어를 통한 폴리다이아세틸렌의 센싱감도 향상 (Sensitivity Enhancement of Polydiacetylene Vesicles through Control of Particle Size and Polymerization Temperature)

  • 이길선;오재호;안동준
    • Korean Chemical Engineering Research
    • /
    • 제49권4호
    • /
    • pp.400-404
    • /
    • 2011
  • 폴리다이아세틸렌(polydiacetylene: PDA)은 독특한 광학적 특성, 즉 외부자극에 의하여 파란색에서 빨간색으로 색상이 변화하는 동시에 형광이 없던 상태에서 자가형광을 발현하는 특성 때문에 화학, 바이오센서로써 응용하기 위한 많은 연구들이 진행되어 왔다. 특히, 센서의 성능에서 감지하고자 하는 물질에 대한 우수한 민감도는 매우 중요하다. 본 연구에서는 다양한 필터 사이즈를 이용하여 10,12-pentacosadynoic acid(PCDA) 베시클의 크기를 조절함과 동시에 중합온도를 조절하여 ${\alpha}$-사이클로텍스트린(CD)을 검출하여 두 가지 효과가 민감도 향상에 어떤 영향을 미치는지 조사하였다. 필터를 사용하지 않은 베시클과 0.22 ${\mu}m$로 필터한 베시클을 $25^{\circ}C$에서 고분자한 후에 ${\alpha}$-CD(5 mM)와 30분 반응하였을 때 색전이 정도(colorimetric response, CR)가 31.4%에서 74.0%로 증가하였다. 또한, 0.22 ${\mu}m$로 필터한 베시클을 $25^{\circ}C$$5^{\circ}C$에서 고분자한 후에 ${\alpha}$-CD(5 mM)와 30분 반응하였을 때 CR값이 74.0%에서 99.2%로 증가하였다. 이는 폴리다이아세틸렌의 크기와 고분자시 온도를 조절함으로써 민감도를 크게 증가시킬 수 있음을 보여준다. 또한, 폴리다이이아세틸렌은 감도 향상이 매우 중요한 바이오물질을 검출하는데 적용될 수 있을 것이다.

유전성 대사질환의 신생아 스크리닝 (Newborn screening of inherited metabolic disease in Korea)

  • 이동환
    • Clinical and Experimental Pediatrics
    • /
    • 제49권11호
    • /
    • pp.1125-1139
    • /
    • 2006
  • In 1991, the Ministry of Health & Social affairs adopted a nationwide service program for neonatal screening of phenylketonuria, galactosemia, maple syrup urine disease, homocystinuria, histidinemia & congenital hypothyroidism for newborns delivered from low class pregnant women registered in health centers. Government decreased the test items from six to two, PKU & congenital hypothyroidism to increase test numbers with same budget from 1995. Government decided to test PKU & hypothyroidism for all newborns from 1997. 78 laboratories wanted to participate for neonatal screening test in 1999. Government didn't decide laboratory center for a certain district and placed responsibility on free competition. Government are planning to test 573,000 newborns from 1998, Government decided to screen 6 items PKU, congenital hypothyroidism, maple syrup urine disese, homocystinuria, galactosemia and congenital adrenal hyperplasia from 2006. 17 laboratores are participating now. The cost of screening test is supported by both the federal government and local government on a 40-60 basis. In case a patient with an inherited metabolic disease is diagnosed by screening of government program, special milk is provided at government's expense. Interlaboratory quality control was started 6 times a year from 1994. According to the government project, 3,707,773 newborns were screened. 86 PKU, 718 congenital hypothyroidism were detected. So incidence of PKU is 1/43,114 and congenital hypothyroidism is 1/4,612. Maeil dairy company produced new special formula for PKU, MMA and PA, MSUD, urea cycle disorder, homocystinuria, isovaleric acidemia from Oct. 1999. The cost benefit of performing screening procedures coupled with treatment has been estimated to be as high as 1.77 times in PKU, 11.11 times in congenital hypothyroidism than cost without screening. We are trying to increase the budget to test all newborns for Tandem mass sereening & Wilson disease from 2008. Now it is a very important problem to decrease laboratory numbers of neonatal screening in Korea. So we are considering 4-5 central laboratories which cover all newborns and are equipped with tandem mass spectrometer & enzyme immunoassay for TSH, 17OHP & enzyme colorimetric assay for galactose.

한국 신생아 집단검사의 과거, 현재, 미래 (The Past, Present, Future of Newborn Screening in Korea)

  • 이동환
    • 대한유전성대사질환학회지
    • /
    • 제14권1호
    • /
    • pp.1-9
    • /
    • 2014
  • Many inborn errors of metabolism can be completely cured with early detection and early treatment. This is why neonatal screening on inborn errors of metabolism is implemented worldwide. In 1991, the Ministry of Health & Social affairs adopted a nationwide service program for neonatal screening of phenylketonuria, galactosemia, maple syrup urine disease, homocystinuria, histidinemia and congenital hypothyroidism for newborns delivered from low class pregnant women registered in health centers. Government decreased the test items from six to two, PKU and congenital hypothyroidism to increase test numbers with same budget from 1995. 78 laboratories wanted to participate for neonatal screening test in 1999. Government decided to screen six items of PKU, congenital hypothyroidism, maple syrup urine disease, homocystinuria, galactosemia and congenital adrenal hyperplasia from 2006. In 2014, thirteen laboratories are participating. Inter laboratory quality control was started 6 times a year from 1994. In case a patient with an inherited metabolic disease is diagnosed by screening of government program, special milk is provided at government's expense. According to the government project, from 1997 to 2013, 7,080,569 newborns were screened. 144 PKU, 2.451 congenital hypothyroidism were detected. So incidence of PKU is 1/49,170 and congenital hypothyroidism is 1/2,888. The cost benefit of performing screening procedures coupled with treatment has been estimated to be as high as 1.77 times in PKU, 11.11 times in congenital hypothyroidism than cost without screening. By January 2007, many European countries had expanded of their newborn screening programs by inclusion of Tandem mass spectrometry. We are trying to increase the budget to test all newborns for Tandem mass spectrometry from 2016. We are considering four to five central laboratories which cover all newborns and are equipped with tandem mass spectrometer & enzyme immunoassay for TSH, 17OHP & enzyme colorimetric assay for galactose. And I hope to expand test including Wilson disease screening test and lysosomal storage diseases.