Determination of Cholesterol by a Diode Laser/Fiber Optic Colorimetric Spectrometer

  • Kim, Seong Ho;Nam, Seong Man;Byeon, Sang Gil;Yun, Sin Yeong;Hong, Seong Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.389-392
    • /
    • 2000
  • A simple and inexpensive colorimetric spectrometer for determining total cholesterol has been developed,comprising a diode laser as the light sourcoptical fibers for the light guide and a photodiode as the detector.The stabilty and performance of the new system was investigated by obtaining the calibration curve for stan-dard cholesterol solutions. The total cholesterol in humanserum was also measured by the analyzer and com-pared with the value obtained by a conventional spectrometer. The results showed that the developed spectrometer was useful for the determination of cholesterol levels. The visible diodelaser used in the study exhibited good spectroscopic and operational properties for colorimetric absorption spectrometry and could be a key component for the development of a simple and economical analyzer.

Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors

  • Heo, Eun-Yeong;Ko, Young-Il;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.21 no.5
    • /
    • pp.51-57
    • /
    • 2009
  • Since heavy metal pollution is a significant global environmental problem and very dangerous to human health, the improved methods for detecting heavy metals are required recently. Colorimetric chemosensors are now considered as one of the most effective analytical method used in the environment monitoring. New direct dyes having the function of colorimetric chemosensors were synthesized. When metal ions such as $Al^{3+}$, $Ca^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Cu^{2+}$, $Fe^{2+}$, $Fe^{3+}$, $Hg^{2+}$, $Li^+$, $Mg^{2+}$, $Na^+$, $Ni^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ were added each solution of new direct dyes, the color of solution was changed and can be easily detected with naked eyes without expensive experimental equipment such as atomic absorption spectrometer (AAS) or inductively coupled plasma?mass spectrometer (ICP-MS). The new benzidine analogues were diazotized and reacted with couplers such as H-acid, J-acid, Chromotropic acid, Nevill-winther acid and gamma acid to synthesize new direct dyes. The structures of the new direct dyes were confirmed by high resolution mass spectrometer (FAB ionization) and evaluated with UV-Vis spectroscopy. The UV-VIS spectroscopy was measured for the dye solutions by adding various concentrations of metal ions. It was observed that the absorbance in UV-Vis spectra was changed as the heavy metal ions were added.

Application of a Diode Laser Colorimetric Spectrometer to Determination of Cetylpyridinium Chloride (다이오드 레이저 비색 분광기를 이용한 Cetylpyridinium Chloride의 농도분석)

  • Park, Keun-Woo;Kim, Se-Yun;Shin, Chul-Min;Seo, Jeong-Woon;Hyun, Hye-Jin;Nam, Hae-Seon;Kim, Sung-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.307-310
    • /
    • 2003
  • In order to analyze the concentration of cetylpyridinium chloride(CPC), a widely used cationic surfactant, we developed a simple and compact spectrometer, which consisted of a diode laser and a photodiode detector. Preliminary results are described here on the performances of the system in terms if the stability of output intensity, sensitivity, and reproducibility. Data on the comparisons of the system with the conventional UV-VIS spectrometer are also given. With the instrument, the concentration of CPC between 3${\times}$10$\^$-5/M and 1.1${\times}$ 10$\^$-4/M are calibrated as a correlation coefficient of 0.9635. The results shown here indicate a potential for developing a portable spectrometer useful for analyzing concentrations of CPC.

  • PDF

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

Plant Analysis Methods for Evaluating Mineral Nutrient

  • Lee, Ye-Jin;Sung, Jwa-Kyung;Lee, Seul-Bi;Lim, Jung-Eun;Song, Yo-Sung;Lee, Deog-Bae;Hong, Suk-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.2
    • /
    • pp.93-99
    • /
    • 2017
  • Analysis of mineral nutrients in plant is required for evaluating diagnosis of plant nutritional status. Pretreatment procedure for the analysis of plant can be varied depending on elements to be analyzed. Wet-digestion is suitable for total nitrogen, phosphate and cations, however, digestion solution including nitric acid is not suitable for nitrogen analysis. Incineration procedure is required to analyze chloride, silicate and total sulfur. After digestion, total nitrogen is analyzed by Kjeldahl method, and phosphate is detected at 470nm by colorimetric analysis with ammonium meta vanadate. Cations and micro elements are determined by titration or colorimetry, also, these elements can be measured by Atomic absorption spectrometer (AAS) or Inductively coupled plasma spectrometer (ICP).

Sensitivity Enhancement of Polydiacetylene Vesicles through Control of Particle Size and Polymerization Temperature (입자크기와 중합온도 제어를 통한 폴리다이아세틸렌의 센싱감도 향상)

  • Lee, Gil Sun;Oh, Jae Ho;Ahn, Dong June
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.400-404
    • /
    • 2011
  • Many studies on polydiacetylene(PDA) have been investigated to apply to chemical and biological sensors due to their unique optical properties of color change from blue to red and fluorescence change from non-fluorescence to red fluorescence. Especially, high sensitivity against specific molecules is very important to apply polydiacetylenes to various sensors. In this study, we examined the effect of sensitivity enhancement of 10,12-pentacosadynoic acid(PCDA) vesicles in detection ${\alpha}$-cyclodextrin(CD) according to control of vesicle size by filters with different pore sizes and polymerization temperature. Colorimetric response(CR) was calculated using visible spectrometer. In order to investigate the effect of vesicle size on sensitivity of PDA vesicles, two PCDA vesicles were filtered without filtration and with 0.22 ${\mu}m$ filter. The two PCDA vesicles were polymerized at $25^{\circ}C$ and were incubated with ${\alpha}$-CD(5 mM) for 30 min. The CRs of the former and latter vesicles were 31.4% and 74.0%, respectively. Then, two PCDA vesicles filtered with 0.22 ${\mu}m$ filter were polymerized at $25^{\circ}C$ and $5^{\circ}C$ and were reacted with ${\alpha}$-CD(5 mM) for 30 min to examine the effect of polymerization temperature. The CRs of the former and latter vesicles were 74.0 and 99.2%, respectively. This suggests that vesicle sizes and polymerization temperature are key factors in enhancing the sensitivity of PDA vesicles. In addition, these results are expected to be useful to apply the PDA vesicles as biosensors to detect DNA, protein, and cells.

Newborn screening of inherited metabolic disease in Korea (유전성 대사질환의 신생아 스크리닝)

  • Lee, Dong Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1125-1139
    • /
    • 2006
  • In 1991, the Ministry of Health & Social affairs adopted a nationwide service program for neonatal screening of phenylketonuria, galactosemia, maple syrup urine disease, homocystinuria, histidinemia & congenital hypothyroidism for newborns delivered from low class pregnant women registered in health centers. Government decreased the test items from six to two, PKU & congenital hypothyroidism to increase test numbers with same budget from 1995. Government decided to test PKU & hypothyroidism for all newborns from 1997. 78 laboratories wanted to participate for neonatal screening test in 1999. Government didn't decide laboratory center for a certain district and placed responsibility on free competition. Government are planning to test 573,000 newborns from 1998, Government decided to screen 6 items PKU, congenital hypothyroidism, maple syrup urine disese, homocystinuria, galactosemia and congenital adrenal hyperplasia from 2006. 17 laboratores are participating now. The cost of screening test is supported by both the federal government and local government on a 40-60 basis. In case a patient with an inherited metabolic disease is diagnosed by screening of government program, special milk is provided at government's expense. Interlaboratory quality control was started 6 times a year from 1994. According to the government project, 3,707,773 newborns were screened. 86 PKU, 718 congenital hypothyroidism were detected. So incidence of PKU is 1/43,114 and congenital hypothyroidism is 1/4,612. Maeil dairy company produced new special formula for PKU, MMA and PA, MSUD, urea cycle disorder, homocystinuria, isovaleric acidemia from Oct. 1999. The cost benefit of performing screening procedures coupled with treatment has been estimated to be as high as 1.77 times in PKU, 11.11 times in congenital hypothyroidism than cost without screening. We are trying to increase the budget to test all newborns for Tandem mass sereening & Wilson disease from 2008. Now it is a very important problem to decrease laboratory numbers of neonatal screening in Korea. So we are considering 4-5 central laboratories which cover all newborns and are equipped with tandem mass spectrometer & enzyme immunoassay for TSH, 17OHP & enzyme colorimetric assay for galactose.

The Past, Present, Future of Newborn Screening in Korea (한국 신생아 집단검사의 과거, 현재, 미래)

  • Lee, Dong Hwan
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Many inborn errors of metabolism can be completely cured with early detection and early treatment. This is why neonatal screening on inborn errors of metabolism is implemented worldwide. In 1991, the Ministry of Health & Social affairs adopted a nationwide service program for neonatal screening of phenylketonuria, galactosemia, maple syrup urine disease, homocystinuria, histidinemia and congenital hypothyroidism for newborns delivered from low class pregnant women registered in health centers. Government decreased the test items from six to two, PKU and congenital hypothyroidism to increase test numbers with same budget from 1995. 78 laboratories wanted to participate for neonatal screening test in 1999. Government decided to screen six items of PKU, congenital hypothyroidism, maple syrup urine disease, homocystinuria, galactosemia and congenital adrenal hyperplasia from 2006. In 2014, thirteen laboratories are participating. Inter laboratory quality control was started 6 times a year from 1994. In case a patient with an inherited metabolic disease is diagnosed by screening of government program, special milk is provided at government's expense. According to the government project, from 1997 to 2013, 7,080,569 newborns were screened. 144 PKU, 2.451 congenital hypothyroidism were detected. So incidence of PKU is 1/49,170 and congenital hypothyroidism is 1/2,888. The cost benefit of performing screening procedures coupled with treatment has been estimated to be as high as 1.77 times in PKU, 11.11 times in congenital hypothyroidism than cost without screening. By January 2007, many European countries had expanded of their newborn screening programs by inclusion of Tandem mass spectrometry. We are trying to increase the budget to test all newborns for Tandem mass spectrometry from 2016. We are considering four to five central laboratories which cover all newborns and are equipped with tandem mass spectrometer & enzyme immunoassay for TSH, 17OHP & enzyme colorimetric assay for galactose. And I hope to expand test including Wilson disease screening test and lysosomal storage diseases.